Changeover Valve for Twin Safety Valves, Mechanical Interlock

Changeover valves for duty/standby pairs of safety valves: 1/2" to 20", Class 150 to 2500; one handwheel switches inlet and outlet together so one valve can be serviced while the other protects the plant.
Key features
- Valve type: Changeover valve for safety valves
- Construction: Twin-valve manifold, interlocked inlet and outlet changeovers
- Design standard: API 520, ASME VIII
- Size range: 1/2" to 20" (DN15 to DN500)
- Pressure class: ASME Class 150 to 2500; PN10 to PN420
- Body material: Carbon steel, alloy steel, stainless steel, duplex, nickel alloys
- End connections: Flanged
- Operation: Handwheel with chain interlock
- Valve type
- Changeover valve for safety valves
- Design standard
- API 520, ASME VIII
- Pressure class
- ASME Class 150 to 2500; PN10 to PN420
- End connections
- Flanged
- Operation
- Handwheel with chain interlock
Product description
Two safety valves on a common manifold, one in service and one on standby. A changeover valve switches the protected system from one to the other, and in the interlocked version a chain links inlet and outlet changeovers so both move together from one handwheel; the plant is never left unprotected while a valve is removed for testing.
A safety relief valve opens automatically when pressure reaches its set point and closes again once it falls, protecting a vessel, line or tank from bursting. It is the last safeguard after the control system, so it is sized to the worst relieving case, set and tested on the bench, and sealed against tampering.
Construction
- Inlet changeover valve; outlet changeover with mechanical interlock
- Single handwheel moves inlet and outlet together
- Full relieving capacity through either valve
- Flanged to the safety valves and the line
Sizes and ratings
Published range: 1/2" to 20" (DN15 to DN500), ASME Class 150 to 2500; PN10 to PN420, in carbon steel, alloy steel, stainless steel, duplex, nickel alloys. End connections: Flanged. Operation: handwheel with chain interlock.
Each valve is sized to the relieving case; the data sheet and general arrangement drawing come with the quotation.
Testing and documents
Shell and seat-leakage tests, with the material certificates and the pressure-test record supplied with the valve. Third-party inspection and extra tests are added when the order specifies them.
Supply
Changeover valves are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator; standard carbon-steel sizes move fastest. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other safety and relief valves in the range, for comparison when the duty is not settled yet: Tank Pressure Relief Valve (Breather), API 2000, Tank Vacuum Relief Valve, API 2000, Pressure/Vacuum Relief Valve (Conservation Vent), API 2000, Tank Emergency Vent, 16" to 24", API 2000.
Identification
| Parameter | Value |
|---|---|
| Valve type | Changeover valve for safety valves |
| Construction | Twin-valve manifold, interlocked inlet and outlet changeovers |
Standards
| Parameter | Value |
|---|---|
| Design standard | API 520, ASME VIII |
| Pressure testing | Shell and seat-leakage tests |
Range
| Parameter | Value |
|---|---|
| Size range | 1/2" to 20" (DN15 to DN500) |
| Pressure class | ASME Class 150 to 2500; PN10 to PN420 |
Materials
| Parameter | Value |
|---|---|
| Body material | Carbon steel, alloy steel, stainless steel, duplex, nickel alloys |
Construction
| Parameter | Value |
|---|---|
| End connections | Flanged |
| Operation | Handwheel with chain interlock |
Application
| Parameter | Value |
|---|---|
| Typical service | Continuous plants needing on-line relief valve maintenance |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with material certificates and the test record |
Shipping & lead time
What is the Changeover Valve for Twin Safety Valves, Mechanical Interlock and what is it used for?▾
Why interlock the inlet and outlet changeover valves?▾
What sizes and pressure classes does the Changeover Valve for Twin Safety Valves, Mechanical Interlock cover?▾
Does the changeover valve reduce the relieving capacity?▾
What pressure and temperature range does the changeover valve for twin safety valves work in?▾
What body materials does the changeover valve for twin safety valves come in?▾
Which standards apply to the changeover valve for twin safety valves, and how is it tested?▾
What end connections and operation does the changeover valve for twin safety valves have?▾
How do I use the changeover valve to test one safety valve on line?▾
How does the changeover valve differ from a safety relief valve?▾
What documents come with the changeover valve for twin safety valves, and can you supply against a project specification?▾
How is the changeover valve for twin safety valves supplied, and how long does it take?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations