Precast Concrete Lifting Beams — EN 13155

Lifting beams and spreaders for precast concrete walls, floor slabs and stair units, including counterweight beams for installing walls under a structure, engineered to EN 13155.
Key features
- Product type: Precast lifting beam (made to order)
- Pattern / standard: EN 13155; ASME B30.20 / BTH-1 or DNV offshore design on request
- Size range: Built to the precast unit
- Working load limit: To order
- Material
- Structural steel, grade to the design
Product description
Precast units have cast-in lifting anchors at set positions, and the beam is designed so that every anchor takes its share and the unit hangs at the angle it is installed at. Flooring spreaders keep slab anchors loaded vertically; wall beams hang units upright.
Counterweight versions place wall units under an existing floor or canopy where the hook cannot reach.
Typical builds
- Precast wall lifting beams
- Floor slab spreader beams
- Counterweight beams for wall installation
- Stair and special-unit beams
What we need to quote
Send us the load weight and where its centre of gravity sits, the load's length and width, the positions of its lifting points, the crane hook height and any headroom limit, and the environment the equipment will work in (indoor, outdoor, offshore, hazardous area). A drawing, a 3D model or a photo of the load is the quickest way to start.
How it is made and certified
Engineered below-the-hook equipment is built to order. Your enquiry is reviewed by the maker's design engineers, who issue a general arrangement drawing for your approval before anything is made. Each item is designed to EN 13155, load tested before dispatch and supplied with a declaration of conformity, a test certificate and user instructions. Design calculations, material certificates, NDT records and third-party witnessed testing can be added to the order, and offshore designs to DNV standards are available on request. We confirm the lead time with the quotation.
In service
In service, the equipment gets a pre-use check before every lift and a thorough examination by an approved third party at the interval the site's authority sets: in Abu Dhabi, Code of Practice 34 sets six months for lifting accessories and twelve for lifting equipment, and in Dubai the examination is made by an EIAC-accredited inspection body. Its rated load, identification and test date are marked on it, and the user instructions state how it may and may not be rigged. Our guide to lifting equipment inspection in the UAE sets out the rules emirate by emirate.
Identification
| Parameter | Value |
|---|---|
| Product type | Precast lifting beam (made to order) |
| Pattern / standard | EN 13155; ASME B30.20 / BTH-1 or DNV offshore design on request |
Performance
| Parameter | Value |
|---|---|
| Working load limit | To order |
Dimensions
| Parameter | Value |
|---|---|
| Size range | Built to the precast unit |
Construction
| Parameter | Value |
|---|---|
| Material | Structural steel, grade to the design |
| Finish | Paint system to your specification; galvanized for outdoor use on request |
Compliance
| Parameter | Value |
|---|---|
| Certification | Load tested before dispatch; declaration of conformity |
Supply
| Parameter | Value |
|---|---|
| Supply | Made to order from an approved general arrangement drawing |
| Documentation | GA drawing for approval, declaration of conformity, test certificate, user instructions |
Shipping & lead time
What are Precast Concrete Lifting Beams used for?▾
What is the part number for Precast Concrete Lifting Beams?▾
What sizes and capacities do Precast Concrete Lifting Beams come in?▾
How do I choose the right design of Precast Concrete Lifting Beams?▾
What is the rated load of Precast Concrete Lifting Beams?▾
What material and finish do Precast Concrete Lifting Beams have?▾
What standard are Precast Concrete Lifting Beams designed to?▾
What rigging do Precast Concrete Lifting Beams need?▾
How are Precast Concrete Lifting Beams inspected in service?▾
What are typical builds of Precast Concrete Lifting Beams?▾
How do Precast Concrete Lifting Beams differ from the nearest beam type?▾
Is the Precast Concrete Lifting Beams range available to order from Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Lifting & rigging
Centre of gravity in lifting: load share, tilt and why lifting points belong above it
A suspended load turns until its centre of gravity hangs directly under the hook. That one rule tells you how much each sling leg carries, how far a load will tilt, and why lifting from below the centre of gravity can roll a load over. With worked numbers and what it means for spreader beams.
8 min read
Lifting & rigging
Spreader beam vs lifting beam: how each carries the load, and how to choose
A lifting beam hangs from one top point and carries the load in bending. A spreader beam hangs from two top slings and only holds them apart, in compression. That one difference decides the weight of the beam, the headroom it needs and the loads it suits.
7 min read
Lifting & rigging
Lifting bars for air handling units: why a pipe through the base is not lifting equipment
Many air handling units arrive with holes or fork pockets in the base frame and no lifting lugs. The bar pushed through those holes is a lifting accessory, with everything that implies: a design, a marked SWL, a certificate and periodic examination. What a proper bar set looks like, why one bar is not enough, and who has to provide it.
7 min read