Parker 07L Standard General Industrial Lubricators

Parker 07L Standard General Industrial Lubricators: 4 part numbers.
Product description
Parker 07L Standard General Industrial Lubricators: 4 part numbers.
Specification
- Pressure stated by the maker: 150 to 175 psi (10 to 12 bar), by size
- Seal Material: Nitrile Rubber
- Part numbers: 4
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Sizing air preparation
Size filters, regulators and lubricators on port size and the air flow the downstream tools and cylinders need, not on line size alone; an undersized unit drops pressure at full flow. Quote the maker part number and we will confirm bowl, drain and gauge options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Adjustment Type | Locking Knob, Nonrising |
| Air Preparation Product Type | Lubricator |
| Air Preparation Series | General Industrial Series |
| Body Material | Zinc |
| Bowl Material | Plastic |
| Dome Material | Polycarbonate |
| Drain Included | No |
| For Fluid Type | Compressed Air |
| For Substance Type | Air |
| Included | Bowl, Fill Plug, Guard, Sight Dome |
| Lubricator Bowl Guard Included | Yes |
| Lubricator Bowl Guard Material | Steel |
| Lubricator Type | Mist |
| Modular Connection | Modular Connection |
| No. Of Air Inlets | 1 |
| No. Of Air Outlets | 1 |
| Oil Feed Type | Mist |
| Recommended Lubricant | F442 Oil |
| Seal Material | Nitrile Rubber |
| Series | 07L STANDARD Series |
| Sight Dome Included | Yes |
| Sight Gauge Included | Yes |
| System Location | Air Line |
Shipping & lead time
Sizes & part numbers
4 sizes- Parker Hannifin part no.07L32BE
- Description
- Compressed Air Lubricator, Mist, 1/2 Inch NPT, 90 cfm, 150 psi Max Op Pressure
- Max pressure (psi)
- —
- Ports
- 1/2"
- Parker Hannifin part no.07L44BE
- Description
- Industrial Lubricator
- Max pressure (psi)
- —
- Ports
- 3/4"
- Parker Hannifin part no.07L42BE
- Description
- Compressed Air Lubricator, Mist, 3/4 Inch NPT, 90 cfm, 150 psi Max Op Pressure
- Max pressure (psi)
- 150
- Ports
- 3/4"
- Parker Hannifin part no.07L34BE
- Description
- Lubricator, Mist, 1/2 Inch NPT, 90 scfm, 175 psig Max Op Pressure, 175 deg.F Max Op Temp
- Max pressure (psi)
- 175
- Ports
- 1/2"
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is the Parker 07L Standard general industrial lubricator?▾
How do you read a Parker 07L part number such as 07L34BE?▾
Which port sizes does the Parker 07L Standard lubricator come in?▾
What is the maximum pressure of the Parker 07L lubricator?▾
Which oil does Parker recommend for the 07L Standard lubricator?▾
Does the Parker 07L lubricator come with a certificate of conformity?▾
What comes supplied with a Parker 07L Standard lubricator?▾
How do you refill and adjust a Parker 07L lubricator?▾
Which machines suit a Parker 07L Standard lubricator?▾
Should I choose a Parker 07L mist lubricator or a 17L micro-mist lubricator?▾
Where are Parker 07L lubricators made, and which HS heading applies?▾
Can I buy Parker 07L Standard lubricators ex-stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
FRL units explained: filter, regulator and lubricator — order, grades, drains, bowls and sizing
An FRL is the last thing compressed air passes through before it reaches a valve or cylinder. What each element does and why the order is filter, regulator, lubricator; particulate vs coalescing grades in microns; manual, semi-automatic and automatic drains; relieving regulators; when to lubricate; polycarbonate vs metal bowls; and sizing by flow, not port size.
17 min read
Pneumatics & compressed air
Compressed air quality and ISO 8573-1: purity classes, pressure dew point and where to fix the water
ISO 8573-1 writes air quality as three numbers — particles, water, oil. What [2:4:2] or [7:4:3] actually means, which classes food, paint, tools and valves are commonly specified at, why hot, humid air drops so much water once it is compressed and cooled, and why drains, coalescing filters and dryers — not the FRL at the machine — are where water is removed.
14 min read
Pneumatics & compressed air
How to size a pneumatic cylinder: force, load ratio, pressure at the port and air consumption
Theoretical force is pressure times piston area, and the return stroke only gets the annulus. How much margin Parker recommends, why to size on the pressure at the cylinder rather than the compressor, how to work out air per cycle in free air, a worked example in bar/mm and psi/inch, and force tables for common bores at 6 bar and 80 psi.
22 min read