Parker 14F Mini General Industrial Particulate Filters

Parker 14F Mini General Industrial Particulate Filters: 8 part numbers.
Product description
Parker 14F Mini General Industrial Particulate Filters: 8 part numbers.
Specification
- Type: Filter
- Pressure stated by the maker: 150 to 250 psi (10 to 17 bar), by size
- Part numbers: 8
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Sizing air preparation
Size filters, regulators and lubricators on port size and the air flow the downstream tools and cylinders need, not on line size alone; an undersized unit drops pressure at full flow. Quote the maker part number and we will confirm bowl, drain and gauge options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Air Preparation Product Type | Particulate Filter |
| Air Preparation Series | General Industrial Series |
| Bowl Type | Poly |
| Filter Drain Type | Manual |
| Series | 14F MINI Series |
Shipping & lead time
Sizes & part numbers
8 sizes- Parker Hannifin part no.14F01BB
- Description
- Industrial Particulate Filter
- Max pressure (psi)
- —
- Ports
- —
- Parker Hannifin part no.14F03BB
- Description
- Filter, Particulate, 1/8 Inch NPT, 5 micron, 22 scfm, 250 psig Max Op Pressure
- Max pressure (psi)
- —
- Ports
- —
- Parker Hannifin part no.14F07BB
- Description
- Industrial Particulate Filter
- Max pressure (psi)
- —
- Ports
- —
- Parker Hannifin part no.14F17BB
- Description
- Industrial Particulate Filter
- Max pressure (psi)
- —
- Ports
- —
- Parker Hannifin part no.14F15BB
- Description
- Filter, Particulate, 1/4 Inch NPT, 5 micron, 24 scfm, 150 psig Max Op Pressure
- Max pressure (psi)
- 150
- Ports
- 1/4"
- Parker Hannifin part no.14F13BB
- Description
- Filter, Particulate, 1/4 Inch NPT, 5 micron, 24 scfm, 250 psig Max Op Pressure
- Max pressure (psi)
- 250
- Ports
- 1/4"
- Parker Hannifin part no.14F11BB
- Description
- Filter, Particulate, 1/4 Inch NPT, 5 micron, 24 scfm, 150 psig Max Op Pressure
- Max pressure (psi)
- 150
- Ports
- 1/4"
- Parker Hannifin part no.14F05BB
- Description
- Filter, Particulate, 1/8 Inch NPT, 5 micron, 22 scfm, 150 psig Max Op Pressure
- Max pressure (psi)
- 150
- Ports
- 1/8"
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is the Parker 14F Mini general industrial particulate filter?▾
How do you read a Parker 14F Mini part number such as 14F13BB?▾
Which port sizes does the Parker 14F Mini filter come in?▾
What is the maximum operating pressure of the Parker 14F Mini filter?▾
Can a Parker 14F Mini filter be used with synthetic compressor oil?▾
Does a 5 micron Parker 14F Mini filter meet an ISO 8573-1 class?▾
Which lubricator matches the Parker 14F Mini filter?▾
How is the Parker 14F Mini filter drained and serviced?▾
Where is a Parker 14F Mini particulate filter used?▾
How does the Parker 14F Mini differ from the Parker P31 Mini particulate filter?▾
Where are Parker 14F Mini filters made and which HS code applies?▾
Are Parker 14F Mini particulate filters in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
FRL units explained: filter, regulator and lubricator — order, grades, drains, bowls and sizing
An FRL is the last thing compressed air passes through before it reaches a valve or cylinder. What each element does and why the order is filter, regulator, lubricator; particulate vs coalescing grades in microns; manual, semi-automatic and automatic drains; relieving regulators; when to lubricate; polycarbonate vs metal bowls; and sizing by flow, not port size.
17 min read
Pneumatics & compressed air
Compressed air quality and ISO 8573-1: purity classes, pressure dew point and where to fix the water
ISO 8573-1 writes air quality as three numbers — particles, water, oil. What [2:4:2] or [7:4:3] actually means, which classes food, paint, tools and valves are commonly specified at, why hot, humid air drops so much water once it is compressed and cooled, and why drains, coalescing filters and dryers — not the FRL at the machine — are where water is removed.
14 min read
Pneumatics & compressed air
How to size a pneumatic cylinder: force, load ratio, pressure at the port and air consumption
Theoretical force is pressure times piston area, and the return stroke only gets the annulus. How much margin Parker recommends, why to size on the pressure at the cylinder rather than the compressor, how to work out air per cycle in free air, a worked example in bar/mm and psi/inch, and force tables for common bores at 6 bar and 80 psi.
22 min read