Liquid Hydrogen Lift Check Valve, Vacuum Jacketed

Liquid hydrogen lift check valves: NPS 1/2" to 6", Class 150 to 600, -253 °C to 120 °C, guided spring-return disc, vacuum-jacketed extended body, socket-weld, butt-weld or flanged.
Key features
- Valve type: Check valve, lift type, liquid hydrogen
- Construction: Guided spring-return disc, vacuum-jacketed extended body
- Design standard: ASME B16.34
- Size range: NPS 1/2" to 6" (DN15 to DN150)
- Pressure class: ASME Class 150 to 600
- Body material: Austenitic stainless steel
- End connections: Socket weld, butt-weld, RF flanged
- Operation: Self-acting, spring return
- Valve type
- Check valve, lift type, liquid hydrogen
- Design standard
- ASME B16.34
- Pressure class
- ASME Class 150 to 600
- End connections
- Socket weld, butt-weld, RF flanged
- Operation
- Self-acting, spring return
Product description
Backflow prevention on liquid hydrogen lines. A guided disc with a return spring closes reliably without jamming at -253 °C; the extended, vacuum-jacketed body keeps heat out of the liquid; and the material chemistry is controlled against hydrogen embrittlement.
Liquid hydrogen boils at about -253 °C, colder than every common industrial cryogen except liquid helium, and every watt of heat that reaches it turns liquid into gas. Valves for it use vacuum-jacketed bodies, low-conductivity stem inserts and extended bonnets to keep heat out, and materials chosen to resist hydrogen embrittlement.
Construction
- Guided lift disc with spring return
- Extended body inside a vacuum jacket
- Materials with controlled chemistry for -253 °C
- Socket-weld, butt-weld or flanged ends
Sizes and ratings
Published range: NPS 1/2" to 6" (DN15 to DN150), ASME Class 150 to 600, in austenitic stainless steel. End connections: Socket weld, butt-weld, RF flanged. Operation: self-acting, spring return.
The full dimension and weight table for each class is issued with the quotation, together with the general arrangement drawing for the end connection and operator you choose.
Testing and documents
Shell and seat tests, with helium leak and cryogenic tests, with the material certificates and the pressure-test record supplied with the valve. Third-party inspection and extra tests are added when the order specifies them.
Supply
Liquid hydrogen valves are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other cryogenic and liquid hydrogen valves in the range, for comparison when the duty is not settled yet: Liquid Hydrogen Globe Valve, Bellows Seal, Cryogenic Gate Valve, Extended Bonnet, Cryogenic Globe Valve, Extended Bonnet, Cryogenic Check Valves: Swing, Lift, Dual Plate and Axial Flow.
Identification
| Parameter | Value |
|---|---|
| Valve type | Check valve, lift type, liquid hydrogen |
| Construction | Guided spring-return disc, vacuum-jacketed extended body |
Standards
| Parameter | Value |
|---|---|
| Design standard | ASME B16.34 |
| Pressure testing | Shell and seat tests, with helium leak and cryogenic tests |
Range
| Parameter | Value |
|---|---|
| Size range | NPS 1/2" to 6" (DN15 to DN150) |
| Pressure class | ASME Class 150 to 600 |
| Temperature range | -253 °C to 120 °C |
Materials
| Parameter | Value |
|---|---|
| Body material | Austenitic stainless steel |
Construction
| Parameter | Value |
|---|---|
| End connections | Socket weld, butt-weld, RF flanged |
| Operation | Self-acting, spring return |
Application
| Parameter | Value |
|---|---|
| Typical service | Liquid hydrogen storage and transfer |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with material certificates and the test record |
Shipping & lead time
What is the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed and where is it used?▾
What do the NPS and Class ratings of the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed mean?▾
What sizes does the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed come in?▾
What pressure class and temperature range does the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed cover?▾
What is the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed made of, and how is it built?▾
Which standards and tests apply to the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed?▾
Which end connections and operators does the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed have?▾
Can the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed be installed vertically?▾
What service is the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed used for?▾
How does the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed differ from the Liquid Hydrogen Filter, Vacuum Jacketed?▾
Can the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed be supplied against a project specification or vendor list?▾
Do you stock the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog