Liquid Hydrogen Filter, Vacuum Jacketed

Vacuum-jacketed liquid hydrogen filters: NPS 1/2" to 6", Class 150 to 600, -253 °C to 80 °C, extended housing with PCTFE-insulated insert, socket-weld, butt-weld or flanged.
Key features
- Valve type: Filter (strainer), liquid hydrogen
- Construction: Extended, vacuum-jacketed housing with PCTFE insert
- Design standard: ASME B16.34
- Size range: NPS 1/2" to 6" (DN15 to DN150)
- Pressure class: ASME Class 150 to 600
- Body material: Austenitic stainless steel
- End connections: Socket weld, butt-weld, RF flanged
- Operation: Not applicable (static)
- Valve type
- Filter (strainer), liquid hydrogen
- Design standard
- ASME B16.34
- Pressure class
- ASME Class 150 to 600
- End connections
- Socket weld, butt-weld, RF flanged
- Operation
- Not applicable (static)
Product description
Strainer protection for liquid hydrogen pumps, valves and meters. The housing extends above the line inside a vacuum jacket, so the element can be removed from the top while heat leak into the liquid stays low; a PCTFE insert in the extension cuts the space in which liquid can vaporise.
Liquid hydrogen boils at about -253 °C, colder than every common industrial cryogen except liquid helium, and every watt of heat that reaches it turns liquid into gas. Valves for it use vacuum-jacketed bodies, low-conductivity stem inserts and extended bonnets to keep heat out, and materials chosen to resist hydrogen embrittlement.
Construction
- Extended housing inside a vacuum jacket
- PCTFE-insulated extension reduces vaporisation space
- Element removable from the top cover
- Socket-weld, butt-weld or flanged ends
Sizes and ratings
Published range: NPS 1/2" to 6" (DN15 to DN150), ASME Class 150 to 600, in austenitic stainless steel. End connections: Socket weld, butt-weld, RF flanged. Operation: not applicable (static).
The full dimension and weight table for each class is issued with the quotation, together with the general arrangement drawing for the end connection and operator you choose.
Testing and documents
Shell tests, with helium leak and cryogenic tests, with the material certificates and the pressure-test record supplied with the valve. Third-party inspection and extra tests are added when the order specifies them.
Supply
Liquid hydrogen filters are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other cryogenic and liquid hydrogen valves in the range, for comparison when the duty is not settled yet: Liquid Hydrogen Emergency Shutdown Valve, Liquid Hydrogen Lift Check Valve, Vacuum Jacketed, Liquid Hydrogen Globe Valve, Bellows Seal, Cryogenic Gate Valve, Extended Bonnet.
Identification
| Parameter | Value |
|---|---|
| Valve type | Filter (strainer), liquid hydrogen |
| Construction | Extended, vacuum-jacketed housing with PCTFE insert |
Standards
| Parameter | Value |
|---|---|
| Design standard | ASME B16.34 |
| Pressure testing | Shell tests, with helium leak and cryogenic tests |
Range
| Parameter | Value |
|---|---|
| Size range | NPS 1/2" to 6" (DN15 to DN150) |
| Pressure class | ASME Class 150 to 600 |
| Temperature range | -253 °C to 80 °C |
Materials
| Parameter | Value |
|---|---|
| Body material | Austenitic stainless steel |
Construction
| Parameter | Value |
|---|---|
| End connections | Socket weld, butt-weld, RF flanged |
| Operation | Not applicable (static) |
Application
| Parameter | Value |
|---|---|
| Typical service | Liquid hydrogen pump, meter and valve protection |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with material certificates and the test record |
Shipping & lead time
What is the Liquid Hydrogen Filter, Vacuum Jacketed and where is it used?▾
What do the NPS and Class ratings of the Liquid Hydrogen Filter, Vacuum Jacketed mean?▾
What sizes does the Liquid Hydrogen Filter, Vacuum Jacketed come in?▾
What pressure class and temperature range does the Liquid Hydrogen Filter, Vacuum Jacketed cover?▾
What is the Liquid Hydrogen Filter, Vacuum Jacketed made of, and how is it built?▾
Which standards and tests apply to the Liquid Hydrogen Filter, Vacuum Jacketed?▾
Which end connections and operators does the Liquid Hydrogen Filter, Vacuum Jacketed have?▾
What mesh is the element on the Liquid Hydrogen Filter, Vacuum Jacketed?▾
What service is the Liquid Hydrogen Filter, Vacuum Jacketed used for?▾
How does the Liquid Hydrogen Filter, Vacuum Jacketed differ from the Liquid Hydrogen Lift Check Valve, Vacuum Jacketed?▾
Can the Liquid Hydrogen Filter, Vacuum Jacketed be supplied against a project specification or vendor list?▾
Can I buy the Liquid Hydrogen Filter, Vacuum Jacketed from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog