Liquid Hydrogen Emergency Shutdown Valve

Liquid hydrogen emergency shutdown (ESD) valves: NPS 1/2" to 6", Class 150 to 600, -253 °C to 80 °C, pneumatic actuator, bellows seal, vacuum-jacketed body, socket-weld, butt-weld or flanged.
Key features
- Valve type: Emergency shutdown valve, liquid hydrogen
- Construction: Lift-type valve, bellows seal, vacuum-jacketed body
- Design standard: ASME B16.34
- Size range: NPS 1/2" to 6" (DN15 to DN150)
- Pressure class: ASME Class 150 to 600
- Body material: Austenitic stainless steel
- End connections: Socket weld, butt-weld, RF flanged
- Operation: Pneumatic actuator, spring return
- Valve type
- Emergency shutdown valve, liquid hydrogen
- Design standard
- ASME B16.34
- Pressure class
- ASME Class 150 to 600
- End connections
- Socket weld, butt-weld, RF flanged
- Operation
- Pneumatic actuator, spring return
Product description
Fast, reliable shutdown on liquid hydrogen lines. A pneumatic actuator closes the lift-type valve without jamming; a bellows seal stops hydrogen escaping at the stem; and the vacuum-jacketed extended body keeps heat out of the liquid.
Liquid hydrogen boils at about -253 °C, colder than every common industrial cryogen except liquid helium, and every watt of heat that reaches it turns liquid into gas. Valves for it use vacuum-jacketed bodies, low-conductivity stem inserts and extended bonnets to keep heat out, and materials chosen to resist hydrogen embrittlement.
Construction
- Pneumatic actuator for fast, jam-free closing
- Bellows stem seal
- Extended bonnet, vacuum-jacketed body
- PCTFE-insulated extended stem
Sizes and ratings
Published range: NPS 1/2" to 6" (DN15 to DN150), ASME Class 150 to 600, in austenitic stainless steel. End connections: Socket weld, butt-weld, RF flanged. Operation: pneumatic actuator, spring return.
The full dimension and weight table for each class is issued with the quotation, together with the general arrangement drawing for the end connection and operator you choose.
Testing and documents
Shell and seat tests, helium leak and cryogenic tests, actuator function test, with the material certificates and the pressure-test record supplied with the valve. Third-party inspection and extra tests are added when the order specifies them.
Supply
Liquid hydrogen valves are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other cryogenic and liquid hydrogen valves in the range, for comparison when the duty is not settled yet: Liquid Hydrogen Lift Check Valve, Vacuum Jacketed, Liquid Hydrogen Globe Valve, Bellows Seal, Cryogenic Gate Valve, Extended Bonnet, Cryogenic Globe Valve, Extended Bonnet.
Identification
| Parameter | Value |
|---|---|
| Valve type | Emergency shutdown valve, liquid hydrogen |
| Construction | Lift-type valve, bellows seal, vacuum-jacketed body |
Standards
| Parameter | Value |
|---|---|
| Design standard | ASME B16.34 |
| Pressure testing | Shell and seat tests, helium leak and cryogenic tests, actuator function test |
| Fugitive emissions | Bellows stem seal |
Range
| Parameter | Value |
|---|---|
| Size range | NPS 1/2" to 6" (DN15 to DN150) |
| Pressure class | ASME Class 150 to 600 |
| Temperature range | -253 °C to 80 °C |
Materials
| Parameter | Value |
|---|---|
| Body material | Austenitic stainless steel |
Construction
| Parameter | Value |
|---|---|
| End connections | Socket weld, butt-weld, RF flanged |
| Operation | Pneumatic actuator, spring return |
Application
| Parameter | Value |
|---|---|
| Typical service | Liquid hydrogen storage and transfer, emergency isolation |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with material certificates and the test record |
Shipping & lead time
What is the Liquid Hydrogen Emergency Shutdown Valve and where is it used?▾
What do the NPS and Class ratings of the Liquid Hydrogen Emergency Shutdown Valve mean?▾
What sizes does the Liquid Hydrogen Emergency Shutdown Valve come in?▾
What pressure class and temperature range does the Liquid Hydrogen Emergency Shutdown Valve cover?▾
What is the Liquid Hydrogen Emergency Shutdown Valve made of, and how is it built?▾
Which standards and tests apply to the Liquid Hydrogen Emergency Shutdown Valve?▾
Which end connections and operators does the Liquid Hydrogen Emergency Shutdown Valve have?▾
What fail position is available on the Liquid Hydrogen Emergency Shutdown Valve?▾
What service is the Liquid Hydrogen Emergency Shutdown Valve used for?▾
How does the Liquid Hydrogen Emergency Shutdown Valve differ from the Liquid Hydrogen Butterfly Valve, -253 °C?▾
Can the Liquid Hydrogen Emergency Shutdown Valve be supplied against a project specification or vendor list?▾
Is the Liquid Hydrogen Emergency Shutdown Valve in stock in Dubai, and can you ship it worldwide?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog