HYDAC 0330 R 010 BN4HC Return Line Filter Element, 10 µm, for RF 330
Category image · Seals & AccessoriesHYDAC 0330 R 010 BN4HC: a 10 µm return line filter element for HYDAC's RF 330 filter, with a 3 bar bypass valve in the element and NBR seals. HYDAC now lists the 0330 R 010 element in ON or SN media.
Key features
- Filtration rating: 10 µm
Product description
The HYDAC 0330 R 010 BN4HC is a return line filter element for HYDAC's RF 330 return line filter, which takes one 0330 R element. As with every R element, the 0330 is the element size, not a flow rating.
The code
- 0330 — element size, matching the RF 330 filter
- R — return line element
- 010 — 10 µm filtration rating
- BN4HC — Betamicron glass-fibre media, low-collapse grade (20 bar)
The element carries the filter's bypass valve, cracking at 3 bar as standard; /-B6 gives 6 bar, /-KB no bypass and /-V FPM seals.
Current HYDAC supply
HYDAC no longer lists a 0330 R 010 element in BN4HC media. Its current 10 µm glass-fibre element in this size is 0330 R 010 ON (HYDAC USA) or 0330 R 010 SN Sustainmicron (HYDAC's global shop), material no. 1262993. HYDAC does not say that it supersedes BN4HC, so tell us whether you need BN4HC specifically or will take the current media.
Data
- Filtration: 10 µm
- Bypass: 3 bar, in the element
- Collapse rating: 20 bar (BN4HC media)
- Element size (HYDAC data for 0330 R 010 ON): 48 mm ID × 95 mm OD × 195 mm long
- Construction: microglass media on a steel support tube with NBR seals; flow outside to inside
- Operating temperature: −30 to +100 °C
The housing
The RF 330 mounts on the tank top or inline. It is rated 25 bar nominal, has an aluminium housing with G 2 or SAE 2 in ports, and weighs 4.1 kg with its element.
Ordering
Quote 0330 R 010 BN4HC, or the media you will accept. We supply genuine HYDAC elements and confirm lead time on the quotation.
Performance
| Parameter | Value |
|---|---|
| Filtration rating | 10 µm |
| Filter media | Betamicron BN4HC (glass fibre, low collapse) |
| Bypass | 3 bar, in the element |
| Collapse rating | 20 bar |
Mechanical
| Parameter | Value |
|---|---|
| Mount style | Element for the RF 330 return line filter |
| Seals | NBR |
| Dimensions | 48 mm ID × 95 mm OD × 195 mm (0330 R size) |
Identification
| Parameter | Value |
|---|---|
| Element type | R return line element |
| Current HYDAC equivalent | 0330 R 010 ON / SN, material no. 1262993 |
Shipping & lead time
What is the HYDAC 0330 R 010 BN4HC return line filter element used for?▾
How do I read the code 0330 R 010 BN4HC?▾
Is the HYDAC 0330 R 010 BN4HC still made, and what replaces it?▾
What size is the HYDAC 0330 R element?▾
What bypass setting and collapse rating does the HYDAC 0330 R 010 BN4HC have?▾
What media and seals does the HYDAC 0330 R 010 BN4HC element use?▾
Which standard applies to the HYDAC 0330 R 010 BN4HC return line element?▾
Which housing does the HYDAC 0330 R 010 BN4HC element fit?▾
When should I replace the HYDAC 0330 R 010 BN4HC element?▾
How does the HYDAC 0330 R return line element differ from the 0160 DN pressure element?▾
How do I order the HYDAC 0330 R 010 BN4HC element?▾
Can I buy the HYDAC 0330 R 010 BN4HC return line filter element from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Maintenance & reliability
Contamination during a field hose change: what gets in while the line is open
The pump that fails three weeks after a hose change did not fail by coincidence. Everything that ruins it entered during the twenty minutes the port was open.
5 min read
Cylinders, pumps & motors
Hydraulic power unit components: reservoirs, filters, bell housings, couplings and accumulators
Around every pump and motor in a power unit sit the parts that keep it alive: a reservoir sized to let oil cool and settle, a breather and sight glass, return and pressure filters with an indicator that warns before the bypass opens, a bell housing and jaw coupling that hold the pump in line with the motor, and an accumulator charged with nitrogen to the right pressure. How each is sized, the maker rules that matter, and what to send to replace one.
4 min read