Bijur Delimon PLA Progressive Air-Oil Dividers

Bijur Delimon PLA Progressive Air-Oil Dividers: configured to order (180 order codes), for Air-oil systems; oil. The Delimon PLA meters and distributes oil into air for air-oil lubrication, mainly of rolling-element bearings. From Indus Hydraulics, authorised Bijur Delimon distributor for the Middle East, supplied direct from the manufacturer.
Key features
- Product type: Air-oil / oil mist lubrication
- Series: Bijur Delimon PLA Progressive Air-Oil Dividers
- Drive: Compressed air with metered oil
- Lubrication system: Air-oil
- Lubricant: Oil
- Outlets: 3 Segments All outlets open (01AA 0.1cc); 3 Segments All outlets open (02AA 0.2cc); 3 Segments All outlets open (03AA 0.3cc); 4 Segments All outlets open (01AA 0.1cc); 4 Segments All outlets open (02AA 0.2cc); 4 Segments All outlets open (03AA 0.3cc) (+21 more)
- Product type
- Air-oil / oil mist lubrication
- Drive
- Compressed air with metered oil
- Lubrication system
- Air-oil
- Lubricant
- Oil
Product description
The Delimon PLA meters and distributes oil into air for air-oil lubrication, mainly of rolling-element bearings.
Indus Hydraulics is an authorised Bijur Delimon distributor for the Middle East and supplies genuine units direct from the manufacturer, with the maker's datasheets and manuals.
How it works
A progressive dosing section meters the oil to each outlet, where it is mixed into the air flow. Steel construction, 1/8 BSPP connections, 0 to 80 °C. Built to order code: outlets, metered volume, monitoring and air connections.
Range
Configured to order from 180 order codes (PLA…) — systems Air-oil; lubricants Oil. The order-code table below lists every option.
Where it is used
- rolling mills
- extrusion plants and wire mills
- central air-oil systems for bearing lubrication
Choosing an air-oil system
Air-oil suits high-speed bearings and spindles that need a small, continuous oil feed with cooling air — far less oil than an oil bath or oil mist, and no mist in the workshop. Start from the number of points, the oil grade and the shot each point needs (0.01 to 0.30 cc per cycle), then the air supply: it must be clean and dry, so plan a filter-regulator. Add an oil streak sensor where a lost feed would mean a bearing failure.
Complete systems
These components are one part of a lubrication system. We supply the Bijur Delimon lubricators, distribution, tubing, fittings, controllers and monitoring to match, sized to the number of points and the lubricant. Send us the machine and the lubrication points and we propose the full system.
Order code — PLA Progressive Air-Oil Divider
The order code is PLA followed by one code from each position below, in order. Bijur Delimon lists 180 valid combinations; send us the code (or the options) and we confirm it with the manufacturer before quoting.
| Position | Option | Code | Meaning |
|---|---|---|---|
| 1 | Number of Segments | 03 | 3 Segments |
| 04 | 4 Segments | ||
| 05 | 5 Segments | ||
| 06 | 6 Segments | ||
| 07 | 7 Segments | ||
| 08 | 8 Segments | ||
| 09 | 9 Segments | ||
| 10 | 10 Segments | ||
| 11 | 11 Segments | ||
| 12 | 12 Segments | ||
| 2 | Revision | A | Revision A |
| 3 | Monitoring | 01 | with nonreturn valve & motion indicator |
| 02 | with nonreturn valve & monitoring switch | ||
| 4 | Outlet Codes | AAA | 3 Segments All outlets open (01AA 0.1cc) |
| III | 3 Segments All outlets open (02AA 0.2cc) | ||
| QQQ | 3 Segments All outlets open (03AA 0.3cc) | ||
| AAAA | 4 Segments All outlets open (01AA 0.1cc) | ||
| IIII | 4 Segments All outlets open (02AA 0.2cc) | ||
| QQQQ | 4 Segments All outlets open (03AA 0.3cc) | ||
| AAAAA | 5 Segments All outlets open (01AA 0.1cc) | ||
| IIIII | 5 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQ | 5 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAA | 6 Segments All outlets open (01AA 0.1cc) | ||
| IIIIII | 6 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQ | 6 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAAA | 7 Segments All outlets open (01AA 0.1cc) | ||
| IIIIIII | 7 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQQ | 7 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAAAAA | 9 Segments All outlets open (01AA 0.1cc) | ||
| IIIIIIIII | 9 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQQQQ | 9 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAAAAAA | 10 Segments All outlets open (01AA 0.1cc) | ||
| IIIIIIIIII | 10 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQQQQQ | 10 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAAAAAAA | 11 Segments All outlets open (01AA 0.1cc) | ||
| IIIIIIIIIII | 11 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQQQQQQ | 11 Segments All outlets open (03AA 0.3cc) | ||
| AAAAAAAAAAAA | 12 Segments All outlets open (01AA 0.1cc) | ||
| IIIIIIIIIIII | 12 Segments All outlets open (02AA 0.2cc) | ||
| QQQQQQQQQQQQ | 12 Segments All outlets open (03AA 0.3cc) | ||
| 5 | Accessories | 00 | Without |
| 01 | Slot Angle Bracket | ||
| 02 | Overpressure Indicator 70 Bar | ||
| 03 | Overpressure Indicator 100 Bar | ||
| 04 | Screw Joint Kit (1-4 outlets) | ||
| 05 | Fitting Kit (5-8 outlets) | ||
| 06 | Fitting Kit (9-12 outlets) | ||
| 07 | Fitting Kit (13-16 outlets) | ||
| 08 | Fitting Kit (17-20 outlets) | ||
| 09 | Fitting Kit (21-24 outlets) |
Examples of valid codes: PLA03A01AAA00, PLA03A01AAA01, PLA03A01AAA05.
Identification
| Parameter | Value |
|---|---|
| Product type | Air-oil / oil mist lubrication |
| Series | Bijur Delimon PLA Progressive Air-Oil Dividers |
| Drive | Compressed air with metered oil |
Application
| Parameter | Value |
|---|---|
| Lubrication system | Air-oil |
| Lubricant | Oil |
Connections
| Parameter | Value |
|---|---|
| Outlet thread | 1/8BSPP |
| Connections | oil in 1/8BSPP, air in 1/8BSPP |
Construction
| Parameter | Value |
|---|---|
| Material | Steel |
Environment
| Parameter | Value |
|---|---|
| Operating temperature | 0°C-80°C |
Ordering
| Parameter | Value |
|---|---|
| Order code | PLA… (180 codes) |
| Supply | Genuine Bijur Delimon, direct from the manufacturer (authorised distributor) |
Electrical
| Parameter | Value |
|---|---|
| Monitoring | with nonreturn valve & motion indicator; with nonreturn valve & monitoring switch |
Performance
| Parameter | Value |
|---|---|
| Outlets | 3 Segments All outlets open (01AA 0.1cc); 3 Segments All outlets open (02AA 0.2cc); 3 Segments All outlets open (03AA 0.3cc); 4 Segments All outlets open (01AA 0.1cc); 4 Segments All outlets open (02AA 0.2cc); 4 Segments All outlets open (03AA 0.3cc) (+21 more) |
Shipping & lead time
What are Bijur Delimon PLA Progressive Air-Oil Dividers?▾
How do I read the order code for Bijur Delimon PLA Progressive Air-Oil Dividers?▾
Which part numbers and versions does Bijur Delimon PLA Progressive Air-Oil Dividers cover?▾
How do I choose the right PLA Progressive Air-Oil Dividers for my machine?▾
What pressure, output and reservoir ratings do Bijur Delimon PLA Progressive Air-Oil Dividers have?▾
Which lubricants and viscosities can Bijur Delimon PLA Progressive Air-Oil Dividers handle?▾
Which datasheets and approvals come with Bijur Delimon PLA Progressive Air-Oil Dividers?▾
Can Bijur Delimon PLA Progressive Air-Oil Dividers be supplied as part of a complete lubrication system?▾
Do you supply spare parts and service kits for Bijur Delimon PLA Progressive Air-Oil Dividers?▾
Where are Bijur Delimon PLA Progressive Air-Oil Dividers typically used?▾
How do Bijur Delimon PLA Progressive Air-Oil Dividers differ from Bijur Delimon AV, AVE and AVH Air-Oil Injector Blocks?▾
Is the Bijur Delimon PLA Progressive Air-Oil Dividers available from Indus Hydraulics in Dubai, and what is the lead time?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations