Air-Cooled Heat Exchangers

Air-cooled heat exchangers (air fin coolers) to API 661 / ISO 13706, forced or induced draft, with plug, cover-plate or bonnet headers, built to your data sheet for gas plants, refineries, LNG and power plants. Made to API 661 / ISO 13706, ASME VIII Div 1, ASME PTC 30. Built to your data sheet or drawing and quoted against it, with the documents and inspection your project needs.
Key features
- Product type: Air-Cooled Heat Exchangers
- Construction: Engineered to order, built to your data sheet or drawing
- Standards: API 661 / ISO 13706, ASME VIII Div 1, ASME PTC 30, IOGP S-710, EN 13445
- Outside diameter: Preferred minimum 1.0 in; common 1.0, 1.25, 1.5 in; small packaged units use 5/8-1-1/4 in round finned tubes
- Product type
- Air-Cooled Heat Exchangers
- Construction
- Engineered to order, built to your data sheet or drawing
Product description
Air-cooled heat exchangers (air fin coolers) to API 661 / ISO 13706, forced or induced draft, with plug, cover-plate or bonnet headers, built to your data sheet for gas plants, refineries, LNG and power plants.
Air-Cooled Heat Exchangers are engineered equipment, not catalogue items. We quote against your data sheet or drawing, and the design, materials, inspection and documents follow the code and the specification you give us.
How we build and quote
We work from the API 661 / ISO 13706 data sheet. The thermal design sets the bundle, the number of tube rows and passes and the fan duty; the mechanical design covers the headers, the plenum, the structure and the walkways, with the site's wind, seismic and ambient conditions. Tubes, fins and headers are made to the grades on the data sheet, header welds are fully radiographed or ultrasonically tested, and each bundle is hydrotested and documented to the inspection and test plan. Replacement bundles are built to fit the existing bays.
Specification
- Governing standard: API 661 / ISO 13706 (not API 660, which is shell-and-tube)
- Header types: Plug header (most common; plugs opposite each tube for inspection and rolling); cover-plate header for fouling service roughly below 150 psig; bonnet header where tubesheet is costly alloy (e.g. titanium)
- Plug holes: Plug-hole thread nominal diameter at least tube OD + 1/8 in; thread full depth of plugsheet; plug torque values with lubricant must be submitted
- Fan coverage and dispersion: Fan area >= 40% of bundle face area; dispersion angle <= 45 deg
- Minimum fan diameter: 3 ft (0.9 m)
- Fan diameters offered: 5-40 ft (1.5-12.2 m); fan solutions for air outlet up to 204 C (400 F)
- Tube OD: Preferred minimum 1.0 in; common 1.0, 1.25, 1.5 in; small packaged units use 5/8-1-1/4 in round finned tubes
- Section length: Cooling sections 3-60 ft (0.9-18 m)
- Header design pressure range: 150-11,150 psig (ASME) for gas-compression coolers
- Draft: Forced draft (most units; easier maintenance, fans away from hot air) or induced draft (less hot-air recirculation)
- Control options: VFD, variable-pitch fans, louvers, warm-air recirculation, steam coils / winterization
- Screens: Insect/lint and hail screens mesh No. 8 (ISO 13706 cl. 7.2.11)
- Nozzle loads (per header, plug bundles): Forces 1500 lb transverse / 2500 lb axial to bundle / 3000 lb along nozzle; moments 3000 / 2000 / 4000 ft-lb
- Weld hardness / NDE: Weld and HAZ hardness <= 20 HRC (22 HRC for some grades); all pressure welds full penetration; all welds UT or RT
- Performance test: If specified, per ASME PTC 30
Standards
API 661 / ISO 13706, ASME VIII Div 1, ASME PTC 30, IOGP S-710, EN 13445. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Testing and documents
- Hardness of welds/HAZ
- Hydrotest; drain promptly after test
- Optional PTC 30 performance test
- UT or RT of all header welds
- Documentation, inspection and test plan to the order's code and specification
Where it is used
- Gas processing and compression (gas, propane, lean amine, glycol coolers)
- LNG liquefaction
- Power-plant and gen-set radiators
- Refinery overhead condensers and product coolers
- Water-scarce sites where air cooling replaces cooling water
What to send for a quotation
- Service, fluid, total flow and phase
- Inlet and outlet temperatures, allowable pressure drop and fouling
- Design pressure, design temperature, MDMT and test pressure
- Design ambient dry-bulb temperature, minimum ambient and site elevation
- Plot limits: bay width and length, elevation and bundle orientation
- Forced or induced draft, header type and fan control
- Tube material, OD, wall and length; fin type and material
- Inspection and test plan, and any performance test
Identification
| Parameter | Value |
|---|---|
| Product type | Air-Cooled Heat Exchangers |
| Construction | Engineered to order, built to your data sheet or drawing |
Compliance
| Parameter | Value |
|---|---|
| Standards | API 661 / ISO 13706, ASME VIII Div 1, ASME PTC 30, IOGP S-710, EN 13445 |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | Preferred minimum 1.0 in; common 1.0, 1.25, 1.5 in; small packaged units use 5/8-1-1/4 in round finned tubes |
| Size table | Engineered to order: quoted from your data sheet or drawing |
Quality
| Parameter | Value |
|---|---|
| Testing | Hardness of welds/HAZ; Hydrotest; drain promptly after test; Optional PTC 30 performance test; UT or RT of all header welds |
| Certification | Code documentation and inspection to the order |
Application
| Parameter | Value |
|---|---|
| Typical services | Gas processing and compression (gas, propane, lean amine, glycol coolers); LNG liquefaction; Power-plant and gen-set radiators |
Shipping & lead time
What are air-cooled heat exchangers and which standard covers them?▾
What tube sizes and section lengths do air-cooled heat exchangers use?▾
What fan sizes do air-cooled heat exchangers offer?▾
What design pressure range do air-cooled exchanger headers cover?▾
Which header type should I choose for an air-cooled heat exchanger?▾
Forced draft or induced draft for an air-cooled heat exchanger?▾
What tests apply to air-cooled heat exchangers?▾
What finned tubes go into an air-cooled heat exchanger bundle?▾
What control options can an air-cooled heat exchanger have?▾
Where are air-cooled heat exchangers used?▾
Can you supply air-cooled heat exchangers from Dubai?▾
What data does an air-cooled heat exchanger quotation need?▾