Floating Head Heat Exchangers

Shell-and-tube exchangers with a floating rear head (TEMA P, S, T or W), so the bundle can be pulled for cleaning and is free to expand, built to your data sheet. Made to TEMA (R/C/B), API 660 9th ed. / ISO 16812, ASME VIII Div 1 / EN 13445. Built to your data sheet or drawing and quoted against it, with the documents and inspection your project needs.
Key features
- Product type: Floating Head Heat Exchangers
- Construction: Engineered to order, built to your data sheet or drawing
- Standards: TEMA (R/C/B), API 660 9th ed. / ISO 16812, ASME VIII Div 1 / EN 13445, PED 2014/68/EU
- Product type
- Floating Head Heat Exchangers
- Construction
- Engineered to order, built to your data sheet or drawing
Product description
Shell-and-tube exchangers with a floating rear head (TEMA P, S, T or W), so the bundle can be pulled for cleaning and is free to expand, built to your data sheet.
Floating Head Heat Exchangers are engineered equipment, not catalogue items. We quote against your data sheet or drawing, and the design, materials, inspection and documents follow the code and the specification you give us.
How we build and quote
We work from the TEMA data sheet. The thermal design sets the surface, the number of shells and passes and the tube layout; the mechanical design then follows ASME Section VIII Division 1 or EN 13445, with TEMA class R for refinery service, B for chemical and C for general duty, and API 660 / ISO 16812 where the owner specifies it. Tubes, tube sheets, baffles, shells and channels are made to the grades on the data sheet, the tube-to-tubesheet joints are expanded or welded to a qualified procedure, and each unit is hydrotested and documented to the inspection and test plan before it ships from the fabricating shop.
Specification
- TEMA type code: 3 letters: front head (A, B, C, N, D) / shell (E, F, G, H, J, K, X) / rear head (L, M, N fixed tubesheet; P, S, T, W floating; U = U-tube). Example BEM = bonnet, one-pass shell, fixed bonnet rear
- TEMA classes: R = refinery (most demanding), B = chemical, C = general commercial; R adds recessed/confined gasket and thicker minimums
- Rear head letters: P (outside packed), S (split-ring, e.g. AES), T (pull-through), W (packed lantern ring)
- Use: AES/AET: removable bundle where U-tubes are unsuitable; limited to even tube passes; most expensive removable type
Standards
TEMA (R/C/B), API 660 9th ed. / ISO 16812, ASME VIII Div 1 / EN 13445, PED 2014/68/EU. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Testing and documents
- Documentation, inspection and test plan to the order's code and specification
Where it is used
- Gas processing (amine, glycol, NGL trains)
- LNG pre-cooling and utilities
- Power and desalination (feedwater heaters, seawater coolers)
- Refinery turnaround (T&I) retubing and bundle replacement
What to send for a quotation
- Service, plant location and item number
- Fluids on the shell side and the tube side, flows in and out, and phase
- Inlet and outlet temperatures and inlet pressure on each side
- Physical properties of both fluids, or the simulation file
- Allowable pressure drop and fouling resistance on each side
- Design pressure, design temperature and MDMT on each side; test pressure
- TEMA type and class, or the configuration you need
- Tube material, OD, wall, length and pitch; shell and channel materials
- Corrosion allowance, inspection and test plan, and the code and stamp required
Identification
| Parameter | Value |
|---|---|
| Product type | Floating Head Heat Exchangers |
| Construction | Engineered to order, built to your data sheet or drawing |
Compliance
| Parameter | Value |
|---|---|
| Standards | TEMA (R/C/B), API 660 9th ed. / ISO 16812, ASME VIII Div 1 / EN 13445, PED 2014/68/EU |
Quality
| Parameter | Value |
|---|---|
| Certification | Code documentation and inspection to the order |
Dimensions
| Parameter | Value |
|---|---|
| Size table | Engineered to order: quoted from your data sheet or drawing |
Application
| Parameter | Value |
|---|---|
| Typical services | Gas processing (amine, glycol, NGL trains); LNG pre-cooling and utilities; Power and desalination (feedwater heaters, seawater coolers) |
Shipping & lead time
What is a floating head heat exchanger?▾
What do the TEMA rear head letters P, S, T and W mean?▾
What sizes are floating head heat exchangers made in?▾
What are the limits of AES and AET floating head exchangers?▾
Floating head or U-tube heat exchanger?▾
Which standards apply to floating head heat exchangers?▾
How is a floating head exchanger tested?▾
What materials are used in floating head exchangers?▾
Where are floating head exchangers used?▾
What tube bundles fit floating head exchangers?▾
Can you supply floating head exchangers from Dubai?▾
What do I send for a floating head exchanger quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog