Sun Hydraulics Normally Open, Balanced Poppet, Logic Element, Pressure Adjustable — DODP, DOFP, DOHP, DOJP, Series 1 to 4

Sun Hydraulics Normally Open, Balanced Poppet, Logic Element, Pressure Adjustable: DODP, DOFP, DOHP, DOJP, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Normally Open Balanced Poppet Logic Element
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A, T-23A, T-24A
- Valve function
- Normally Open Balanced Poppet Logic Element
- Series (frame sizes)
- 1 to 4
- Cavity
- T-21A, T-22A, T-23A, T-24A
Product description
A normally open 2-way logic element with a balanced poppet: pressure at ports 1 and 2 does not push it shut, so it switches predictably on its control signal alone, with 5,000 psi (350 bar) at both work ports.
This version
- Normally open.
- Pressure-adjustable control: the element opens at an adjustable pressure, like a relief main stage.
Sizes and cavities
Sun Hydraulics builds this valve in 4 versions:
- DODP — series 1, T-21A cavity, 15 gpm (60 L/min)
- DOFP — series 2, T-22A cavity, 30 gpm (120 L/min)
- DOHP — series 3, T-23A cavity, 60 gpm (240 L/min)
- DOJP — series 4, T-24A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Minimum pilot pressure to shift: 400 psi (28 bar), 300 psi (20 bar)
- Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
Configuration options
The letters after the base model code choose these options (shown for DODP; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
- Setting range: A — 400 - 3000 psi (28 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 400 - 1500 psi (28 - 105 bar), 1000 psi (70 bar) Standard Setting, W — 400 - 4500 psi (28 - 315 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
Selection notes
- Needs a minimum pilot pressure (about 400 psi, 30 bar, on series 1) with the external drain open.
- Same cavity as an unbalanced logic element of the same frame size, so it can replace one.
- X control vents to atmosphere (a fix for existing circuits that may weep over time); E control uses a static external drain, the better choice for new designs.
Where it is used
High-flow switching where the path must stay open with no signal — bypass, unloading and dump functions.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DODPLAN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006 |
Identification
| Parameter | Value |
|---|---|
| Valve function | Normally Open Balanced Poppet Logic Element |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-21A, T-22A, T-23A, T-24A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 400 - 3000 psi (28 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 400 - 1500 psi (28 - 105 bar), 1000 psi (70 bar) Standard Setting, W — 400 - 4500 psi (28 - 315 bar), 1000 psi (70 bar) Standard Setting |
| Max leakage | 10 drops/min.@5000 psi (0,7 cc/min.@350 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.DODP
- Series
- 1
- Cavity
- T-21A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DOFP
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DOHP
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DOJP
- Series
- 4
- Cavity
- T-24A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun DODP to DOJP normally open pressure-adjustable logic element used for?▾
Which model codes does the Sun DODP to DOJP normally open pressure-adjustable logic element cover?▾
What flow and cavity does the Sun DODP to DOJP normally open pressure-adjustable logic element have?▾
What pressure is the Sun DODP to DOJP normally open pressure-adjustable logic element rated for?▾
Which options and seals can I choose on the Sun DODP to DOJP normally open pressure-adjustable logic element?▾
How should I read the selection notes for the Sun DODP to DOJP normally open pressure-adjustable logic element?▾
What hex size and installation torque does the Sun DODP to DOJP normally open pressure-adjustable logic element need?▾
Which seal kits fit the Sun DODP to DOJP normally open pressure-adjustable logic element?▾
Where is the Sun DODP to DOJP normally open pressure-adjustable logic element typically used?▾
How does the Sun DODP to DOJP normally open pressure-adjustable logic element compare with the Sun DKDP to DKJP version?▾
Does Indus supply the Sun DODP to DOJP normally open pressure-adjustable logic element direct from the maker?▾
Is the Sun DODP to DOJP normally open pressure-adjustable logic element in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








