Sun Hydraulics Pilot-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element — LKDC, LKFC, LKHC, LKJC, Series 1 to 4

Sun Hydraulics Pilot-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element: LKDC, LKFC, LKHC, LKJC, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-to-Open Unbalanced Poppet Logic Element
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Pilot-to-Open Unbalanced Poppet Logic Element
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
A spring-closed, unbalanced poppet logic element. Pressure at the work ports pushes it further shut; pressure at the pilot port (port 3) opens it once it exceeds the forces at ports 1 and 2 plus the spring.
Sizes and cavities
Sun Hydraulics builds this valve in 4 versions:
- LKDC — series 1, T-11A cavity, 15 gpm (60 L/min)
- LKFC — series 2, T-2A cavity, 30 gpm (120 L/min)
- LKHC — series 3, T-17A cavity, 60 gpm (240 L/min)
- LKJC — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Pilot area ratios (pilot to port 1 / port 2): 1.8:1 / 2.25:1
- Maximum leakage: 10 drops/min.@1000 psi (0,7 cc/min.@70 bar)
Configuration options
The letters after the base model code choose these options (shown for LKDC; a size may add or drop a choice):
- Control: X — Not Adjustable, E — External 4-SAE Pilot Port, Port 3 Blocked, K — Handknob, L — Manual Override, P — External 1/4 NPTF Pilot Port, Port 3 Blocked
- Setting range: D — 50 psi (3,5 bar)
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be L or X.
Selection notes
- A positive seal separates port 2 from the pilot area.
- Because it responds to pressure at every port, check every stage of the machine cycle against the area ratios.
Where it is used
High-flow switching opened on a pilot signal, for example from a pilot solenoid valve.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example LKDCXDN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006 |
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-to-Open Unbalanced Poppet Logic Element |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | D — 50 psi (3,5 bar) |
| Max leakage | 10 drops/min.@1000 psi (0,7 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | X — Not Adjustable, E — External 4-SAE Pilot Port, Port 3 Blocked, K — Handknob, L — Manual Override, P — External 1/4 NPTF Pilot Port, Port 3 Blocked |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.LKDC
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LKFC
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LKHC
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LKJC
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element used for?▾
Which model codes does the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element cover?▾
What flow and cavity does the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element have?▾
What pressure is the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element rated for?▾
Which options and seals can I choose on the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element?▾
How should I read the selection notes for the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element?▾
What hex size and installation torque does the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element need?▾
Which seal kits fit the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element?▾
Where is the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element typically used?▾
How does the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element compare with the Sun LOHDL version?▾
Does Indus supply the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element direct from the maker?▾
Is the Sun LKDC to LKJC pilot-to-open closed unbalanced logic element in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations