Skip to content
SUN HYDRAULICSIH-SUN-LK-C

Sun Hydraulics Pilot-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element — LKDC, LKFC, LKHC, LKJC, Series 1 to 4

Logic Element CartridgesEx-stock · delivery in 3 days
Sun Hydraulics LKDC pilot-to-open unbalanced poppet logic element, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics LKDC pilot-to-open unbalanced poppet logic element, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics Pilot-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element: LKDC, LKFC, LKHC, LKJC, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Pilot-to-Open Unbalanced Poppet Logic Element
  • Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-11A, T-2A, T-17A, T-19A
Valve function
Pilot-to-Open Unbalanced Poppet Logic Element
Series (frame sizes)
1 to 4
Cavity
T-11A, T-2A, T-17A, T-19A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A spring-closed, unbalanced poppet logic element. Pressure at the work ports pushes it further shut; pressure at the pilot port (port 3) opens it once it exceeds the forces at ports 1 and 2 plus the spring.

Sizes and cavities

Sun Hydraulics builds this valve in 4 versions:

  • LKDC — series 1, T-11A cavity, 15 gpm (60 L/min)
  • LKFC — series 2, T-2A cavity, 30 gpm (120 L/min)
  • LKHC — series 3, T-17A cavity, 60 gpm (240 L/min)
  • LKJC — series 4, T-19A cavity, 120 gpm (480 L/min)

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Pilot area ratios (pilot to port 1 / port 2): 1.8:1 / 2.25:1
  • Maximum leakage: 10 drops/min.@1000 psi (0,7 cc/min.@70 bar)

Configuration options

The letters after the base model code choose these options (shown for LKDC; a size may add or drop a choice):

  • Control: X — Not Adjustable, E — External 4-SAE Pilot Port, Port 3 Blocked, K — Handknob, L — Manual Override, P — External 1/4 NPTF Pilot Port, Port 3 Blocked
  • Setting range: D — 50 psi (3,5 bar)
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be L or X.

Selection notes

  • A positive seal separates port 2 from the pilot area.
  • Because it responds to pressure at every port, check every stage of the machine cycle against the area ratios.

Where it is used

High-flow switching opened on a pilot signal, for example from a pilot solenoid valve.

Installation and seal kits

Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example LKDCXDN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006

Identification

ParameterValue
Valve functionPilot-to-Open Unbalanced Poppet Logic Element
Series (frame sizes)1 to 4
CavityT-11A, T-2A, T-17A, T-19A

Performance

ParameterValue
Capacity15 gpm to 120 gpm (60 L/min to 480 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeD — 50 psi (3,5 bar)
Max leakage10 drops/min.@1000 psi (0,7 cc/min.@70 bar)

Configuration

ParameterValue
Control / adjustmentX — Not Adjustable, E — External 4-SAE Pilot Port, Port 3 Blocked, K — Handknob, L — Manual Override, P — External 1/4 NPTF Pilot Port, Port 3 Blocked
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH

Engineers viewing this also looked at