Sun Hydraulics Vent-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element with Pilot Source from Port 1 — LODA, LOFA, LOHA, LOJA, LOKA, Series 1 to 4

Sun Hydraulics Vent-to-Open, Spring-Biased Closed, Unbalanced Poppet Logic Element with Pilot Source from Port 1: LODA, LOFA, LOHA, LOJA, LOKA, series 1 to 4, 25 gpm to 300 gpm (95 L/min to 1100 L/min), T-11A, T-2A, T-17A, T-19A, T-19AU cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Vent-to-Open Unbalanced Poppet Logic Element
- Capacity: 25 gpm to 300 gpm (95 L/min to 1100 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A, T-19AU
- Valve function
- Vent-to-Open Unbalanced Poppet Logic Element
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A, T-19AU
Product description
A spring-closed, unbalanced poppet logic element that takes its pilot oil from its own work port through an internal orifice. With the control port blocked it stays shut in one direction and acts as a check in the other; vent the control port and it opens, provided there is pressure to overcome the spring.
This version
- Pilot oil is taken from port 1; from port 2 to port 1 it acts as a check while the control port is blocked.
Sizes and cavities
Sun Hydraulics builds this valve in 5 versions:
- LODA — series 1, T-11A cavity, 25 gpm (95 L/min)
- LOFA — series 2, T-2A cavity, 50 gpm (200 L/min)
- LOHA — series 3, T-17A cavity, 100 gpm (380 L/min)
- LOJA — series 4, T-19A cavity, 200 gpm (760 L/min)
- LOKA — series 4, T-19AU cavity, 300 gpm (1100 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Pilot area ratios (pilot to port 1 / port 2): 1.8:1 / 2.25:1
- Maximum leakage: 10 drops/min. (0,7 cc/min)
Configuration options
The letters after the base model code choose these options (shown for LODA; a size may add or drop a choice):
- Control: X — Not Adjustable, E — External 4-SAE Port, Port 3 blocked, L — Stroke Adjustment
- Check cracking pressure: D — 50 psi (3,5 bar)
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated
Option rules: If the modifier is /AP, the control must be L or X.
Selection notes
- It opens quickly when vented; closing time depends on flow and pressure drop and is hard to predict.
- Pilot-source options: port 1, port 2, or either through an internal shuttle.
- A positive seal separates port 2 from the pilot area.
Where it is used
High-flow on/off functions vented by a small 2-way pilot valve — no separate pilot supply needed.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example LODAXDN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Vent-to-Open Unbalanced Poppet Logic Element |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A, T-19AU |
Performance
| Parameter | Value |
|---|---|
| Capacity | 25 gpm to 300 gpm (95 L/min to 1100 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | D — 50 psi (3,5 bar) |
| Max leakage | 10 drops/min. (0,7 cc/min) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | X — Not Adjustable, E — External 4-SAE Port, Port 3 blocked, L — Stroke Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006 |
| Weight | 2.60 lb (1,20 kg) |
Shipping & lead time
Sizes & part numbers
5 sizes- Sun Hydraulics part no.LODA
- Series
- 1
- Cavity
- T-11A
- Capacity
- 25 gpm / 95 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LOFA
- Series
- 2
- Cavity
- T-2A
- Capacity
- 50 gpm / 200 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LOHA
- Series
- 3
- Cavity
- T-17A
- Capacity
- 100 gpm / 380 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LOJA
- Series
- 4
- Cavity
- T-19A
- Capacity
- 200 gpm / 760 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LOKA
- Series
- 4
- Cavity
- T-19AU
- Capacity
- 300 gpm / 1100 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element used for?▾
Which model codes does the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element cover?▾
What flow and cavity does the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element have?▾
What pressure is the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element rated for?▾
Which options and seals can I choose on the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element?▾
How should I read the selection notes for the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element?▾
What hex size and installation torque does the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element need?▾
Which seal kits fit the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element?▾
Where is the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element typically used?▾
How does the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element compare with the Sun LOHDL version?▾
Does Indus supply the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element direct from the maker?▾
Is the Sun LODA to LOKA vent-open unbalanced, pilot from port 1 logic element in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations