Skip to content
SUN HYDRAULICSIH-SUN-FQ-A

Sun Hydraulics Fixed-Orifice, Flow Fuse Valve — FQBA, FQCA, FQEA, FQGA, FQIA, Series 0 to 4

Flow Control CartridgesEx-stock · delivery in 3 days
Sun Hydraulics FQCA flow fuse (velocity fuse), series 1, T-13A cavity — dimension drawing
VIEW 01·Sun Hydraulics FQCA flow fuse (velocity fuse), series 1, T-13A cavity — dimension drawing
1 / 3

Sun Hydraulics flow fuse (velocity fuse): FQBA, FQCA, FQEA, FQGA, FQIA, series 0 to 4, 2.25 gpm to 50 gpm (8,5 L/min to 200 L/min), T-162A, T-13A, T-5A, T-16A, T-18A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Flow Fuse (velocity Fuse)
  • Capacity: 2.25 gpm to 50 gpm (8,5 L/min to 200 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-162A, T-13A, T-5A, T-16A, T-18A
Valve function
Flow Fuse (velocity Fuse)
Series (frame sizes)
0 to 4
Cavity
T-162A, T-13A, T-5A, T-16A, T-18A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A flow fuse holds an actuator in place if a hose or line bursts. Oil flows normally both ways until flow out of the actuator (port 1 to port 2) exceeds the setting; the valve then shuts instantly.

Sizes and cavities

Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:

  • FQBA — series 0, T-162A cavity, 2.25 gpm (8,5 L/min), 0-series
  • FQCA — series 1, T-13A cavity, 6 gpm (23 L/min)
  • FQEA — series 2, T-5A cavity, 15 gpm (60 L/min)
  • FQGA — series 3, T-16A cavity, 25 gpm (95 L/min)
  • FQIA — series 4, T-18A cavity, 50 gpm (200 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 1 in³/min.@1000 psi (15 cc/min.@70 bar), 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)

Configuration options

The letters after the base model code choose these options (shown for FQCA; a size may add or drop a choice):

  • Control: X — Not Adjustable
  • Setting range: A — Replaceable Orifice .5 - 6 gpm (2 - 23 L/min.), B — Permanent Orifice .5 - 6 gpm (2 - 23 L/min.)
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be X.

Selection notes

  • It reacts to any flow surge above the setting, so set it with margin over normal flow.
  • You specify the setting; it is factory set within about ±15%.

Where it is used

Safety on lift cylinders, booms, platforms and any load that could fall if a line fails.

Installation and seal kits

Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990162007, EPDM: 990162014, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990010007, Polyurethane: 990010002, Viton: 990010006; series 2: Buna: 990203007, Viton: 990203006; series 3: Buna: 990016007, Polyurethane: 990016002, Viton: 990016006; series 4: Buna: 990018007, Polyurethane: 990018002, Viton: 990018006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FQCAXAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionFlow Fuse (velocity Fuse)
Series (frame sizes)0 to 4
CavityT-162A, T-13A, T-5A, T-16A, T-18A

Performance

ParameterValue
Capacity2.25 gpm to 50 gpm (8,5 L/min to 200 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — Replaceable Orifice .5 - 6 gpm (2 - 23 L/min.), B — Permanent Orifice .5 - 6 gpm (2 - 23 L/min.)
Max leakage1 in³/min.@1000 psi (15 cc/min.@70 bar), 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)

Configuration

ParameterValue
Control / adjustmentX — Not Adjustable
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Installation

ParameterValue
Valve hex size3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 0: Buna: 990162007, EPDM: 990162014, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990010007, Polyurethane: 990010002, Viton: 990010006; series 2: Buna: 990203007, Viton: 990203006; series 3: Buna: 990016007, Polyurethane: 990016002, Viton: 990016006; series 4: Buna: 990018007, Polyurethane: 990018002, Viton: 990018006
Weight.20 lb (0,10 kg) to 2.90 lb (1,30 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH