Sun Hydraulics 2-Way, Air-Operated, Spool Directional Valve, Pilot Capacity: DAAP, series P, .25 gpm (1 L/min), T-8A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Air-Operated Pilot Directional Valve
- Capacity: .25 gpm (1 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-8A
- Valve function
- Air-Operated Pilot Directional Valve
- Series (frame sizes)
- P
- Cavity
- T-8A
Product description
A small spool valve shifted by compressed air against a return spring. It fits the T-8A pilot cavity, so it can sit in the end of a Sun main-stage or vent-to-operate cartridge and control it from a pneumatic signal.
This version
- Pilot capacity: sized to switch pilot flows to larger valves, not main flows.
Sizes and cavities
Sun Hydraulics builds this valve in one version:
- DAAP — series P, T-8A cavity, .25 gpm (1 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series. Series P parts are pilot cartridges for the small T-8A and T-9A pilot cavities, many of which sit in the end of a larger Sun main stage.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
Configuration options
The letters after the base model code choose these options (shown for DAAP; a size may add or drop a choice):
- Control: E — External 4-SAE Port, F — External 1/8 NPTF Port, P — External 1/8 BSPP Port
- Spool / poppet configuration: C — Normally Closed, H — Normally Open
- Seal material: N — Buna-N, V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated
Option rules: If the modifier is /AP, the control must be E, F or P; If the seal is E, the control must be E,F or P.
Selection notes
- Minimum air pressure to shift is 20 psi plus 1/100 of the pressure at port 1 — about 20 to 70 psi (1.4 to 5 bar).
- Torque the main stage in first, then this pilot into it.
Where it is used
Hydraulic functions controlled from pneumatic panels or air logic, and machines where electrics are unwanted.
Installation and seal kits
Hex 7/8 in. (22,2 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm). Replacement seal kits — series P: Buna: 990508007, Viton: 990508006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DAAPFCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Air-Operated Pilot Directional Valve |
| Series (frame sizes) | P |
| Cavity | T-8A |
Performance
| Parameter | Value |
|---|---|
| Capacity | .25 gpm (1 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Max leakage | 10 drops/min.@5000 psi (0,7 cc/min.@350 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | E — External 4-SAE Port, F — External 1/8 NPTF Port, P — External 1/8 BSPP Port; C — Normally Closed, H — Normally Open |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm) |
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm) |
| Seal kits | series P: Buna: 990508007, Viton: 990508006 |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.DAAP
- Series
- P
- Cavity
- T-8A
- Capacity
- .25 gpm / 1 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics DAAP air-operated pilot directional valve used for?▾
Which sizes and versions does the Sun Hydraulics DAAP air-operated pilot directional valve come in?▾
How do I read the Sun Hydraulics model code DAAPFCN for the DAAP air-operated pilot directional valve?▾
What is the maximum operating pressure of the Sun Hydraulics DAAP air-operated pilot directional valve?▾
What flow capacity does the DAAP air-operated pilot directional valve have?▾
Which seal materials and body finishes does the Sun Hydraulics DAAP air-operated pilot directional valve come with?▾
Which cavity does the Sun Hydraulics DAAP air-operated pilot directional valve fit?▾
Which seal kit fits the Sun Hydraulics DAAP air-operated pilot directional valve?▾
How is the Sun Hydraulics DAAP air-operated pilot directional valve installed?▾
Where is the Sun Hydraulics DAAP air-operated pilot directional valve used?▾
Sun Hydraulics DAAP or DBAP: what is the difference?▾
Do you stock the Sun Hydraulics DAAP in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations