Skip to content
SUN HYDRAULICSIH-SUN-DC-D

Sun Hydraulics 4-Way, 2-Position, Pilot-to-Shift, Detented, Directional Valve — DCCD, DCDD, DCED, DCFD, Series 1 to 4

Check, Shuttle & Directional CartridgesEx-stock · delivery in 3 days
Sun Hydraulics DCCD pilot-to-shift directional spool valve, series 1, T-61A cavity — dimension drawing
VIEW 01·Sun Hydraulics DCCD pilot-to-shift directional spool valve, series 1, T-61A cavity — dimension drawing
1 / 3

Sun Hydraulics 4-Way, 2-Position, Pilot-to-Shift, Detented, Directional Valve: DCCD, DCDD, DCED, DCFD, series 1 to 4, 10 - 13 gpm to 80 - 120 gpm (40 - 50 L/min to 320 - 480 L/min), T-61A, T-62A, T-63A, T-64A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Pilot-to-Shift Directional Spool Valve
  • Capacity: 10 - 13 gpm to 80 - 120 gpm (40 - 50 L/min to 320 - 480 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-61A, T-62A, T-63A, T-64A
Valve function
Pilot-to-Shift Directional Spool Valve
Series (frame sizes)
1 to 4
Cavity
T-61A, T-62A, T-63A, T-64A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A spool directional cartridge moved by hydraulic pilot pressure instead of a solenoid. The 4-way versions are 6-port valves with supply at port 3 and pilot ports X and Y (ports 5 and 6); all ports, pilot ports included, take 5,000 psi (350 bar). A choice of spools sets the flow paths.

This version

  • Detented: it stays in the position it was last piloted to until piloted back.

Sizes and cavities

Sun Hydraulics builds this valve in 4 versions:

  • DCCD — series 1, T-61A cavity, 10 - 13 gpm (40 - 50 L/min)
  • DCDD — series 2, T-62A cavity, 20 - 30 gpm (80 - 120 L/min)
  • DCED — series 3, T-63A cavity, 40 - 60 gpm (160 - 240 L/min)
  • DCFD — series 4, T-64A cavity, 80 - 120 gpm (320 - 480 L/min)

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Minimum pilot pressure to shift: 175 psi (12 bar), 150 psi (10,5 bar), 125 psi (9 bar)
  • Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar)

Configuration options

The letters after the base model code choose these options (shown for DCCD; a size may add or drop a choice):

  • Control: X — Standard Pilot
  • Spool / poppet configuration: C — Blocked Crossover, H — Open Crossover, T — Tandem Crossover, X — P to B and A to T Crossover
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be X.

Selection notes

  • Capacity depends on the spool: flow forces can stop a spool reaching full stroke at high flow and pressure, so higher flows are possible at lower pressures.
  • Check the minimum pilot pressure in the ratings against your pilot supply.

Where it is used

Main-stage directional control piloted from a joystick, a remote pilot valve or a small solenoid pilot.

Installation and seal kits

Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990061007, Polyurethane: 990061002, Viton: 990061006; series 2: Buna: 990062007, Polyurethane: 990062002, Viton: 990062006; series 3: Buna: 990063007, Polyurethane: 990063002, Viton: 990063006; series 4: Buna: 990064007, Polyurethane: 990064002, Viton: 990064006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DCCDXCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionPilot-to-Shift Directional Spool Valve
Series (frame sizes)1 to 4
CavityT-61A, T-62A, T-63A, T-64A

Performance

ParameterValue
Capacity10 - 13 gpm to 80 - 120 gpm (40 - 50 L/min to 320 - 480 L/min)
Max operating pressure5000 psi (350 bar)
Max leakage2 in³/min.@1000 psi (30 cc/min.@70 bar)

Configuration

ParameterValue
Control / adjustmentX — Standard Pilot; C — Blocked Crossover, H — Open Crossover, T — Tandem Crossover, X — P to B and A to T Crossover
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990061007, Polyurethane: 990061002, Viton: 990061006; series 2: Buna: 990062007, Polyurethane: 990062002, Viton: 990062006; series 3: Buna: 990063007, Polyurethane: 990063002, Viton: 990063006; series 4: Buna: 990064007, Polyurethane: 990064002, Viton: 990064006
Weight.40 lb (0,20 kg) to 3.80 lb (1,75 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH