Sun Hydraulics 4-Way, 3-Position, Meter In Proportional Directional Valve — FTCC, FTDC, FTEC, FTFC, FTHC, Series 2 to 4

Sun Hydraulics 4-Way, 3-Position, Meter In Proportional Directional Valve: FTCC, FTDC, FTEC, FTFC, FTHC, series 2 to 4, 7 gpm to 80 gpm (28 L/min to 320 L/min), T-52A, T-53A, T-54A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-Operated 4-Way Meter-In Proportional Directional Valve
- Capacity: 7 gpm to 80 gpm (28 L/min to 320 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-52A, T-53A, T-54A
- Valve function
- Pilot-Operated 4-Way Meter-In Proportional Directional Valve
- Series (frame sizes)
- 2 to 4
- Cavity
- T-52A, T-53A, T-54A
Product description
A 3-position, 4-way spool valve whose opening follows pilot pressure. In centre the supply (port 3) is closed and the work ports drain to port 5; pilot pressure at port 1 meters supply to port 4 in proportion, and pilot at port 6 meters it to port 2. Flow forces give it some self-compensation as load pressure changes.
Sizes and cavities
Sun Hydraulics builds this valve in 5 versions:
- FTCC — series 2, T-52A cavity, 7 gpm (28 L/min)
- FTDC — series 2, T-52A cavity, 18 gpm (70 L/min)
- FTEC — series 3, T-53A cavity, 12 gpm (45 L/min)
- FTFC — series 3, T-53A cavity, 35 gpm (140 L/min)
- FTHC — series 4, T-54A cavity, 80 gpm (320 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Pilot pressure for full shift at rated flow: 290 - 340 psi (20 - 23 bar)
- Maximum leakage: 5.5 in³/min.@1000 psi (90 cc/min.@70 bar), 2.7 in³/min.@500 psi (44 cc/min.@35 bar), 8 in³/min.@1000 psi (131 cc/min.@70 bar), 14 in³/min.@1000 psi (229 cc/min.@70 bar)
Configuration options
The letters after the base model code choose these options (shown for FTHC; a size may add or drop a choice):
- Control: X — Not Adjustable
- Spool / poppet configuration: W — A and B Bleed to T Center, Y — A and B to T Center
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated
Option rules: If the modifier is /AP, the control must be X.
Selection notes
- Pilot ports take 5,000 psi (350 bar), but above about 500 psi (35 bar) the spool is fully shifted and flow does not rise.
- For tighter flow regulation add a separate compensator; Sun shows a bypass compensator for it.
Where it is used
Smooth, proportional motion on mobile functions piloted from hydraulic joysticks or proportional pilot reducing valves.
Installation and seal kits
Hex 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 2: Buna: 990052007, Viton: 990052006; series 3: Buna: 990053007, Viton: 990053006; series 4: Buna: 990054007, Polyurethane: 990054002, Viton: 990054006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FTHCXYN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-Operated 4-Way Meter-In Proportional Directional Valve |
| Series (frame sizes) | 2 to 4 |
| Cavity | T-52A, T-53A, T-54A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 7 gpm to 80 gpm (28 L/min to 320 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Max leakage | 5.5 in³/min.@1000 psi (90 cc/min.@70 bar), 2.7 in³/min.@500 psi (44 cc/min.@35 bar), 8 in³/min.@1000 psi (131 cc/min.@70 bar), 14 in³/min.@1000 psi (229 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | X — Not Adjustable; W — A and B Bleed to T Center, Y — A and B to T Center |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 2: Buna: 990052007, Viton: 990052006; series 3: Buna: 990053007, Viton: 990053006; series 4: Buna: 990054007, Polyurethane: 990054002, Viton: 990054006 |
| Weight | 1.00 lb (0,45 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
5 sizes- Sun Hydraulics part no.FTCC
- Series
- 2
- Cavity
- T-52A
- Capacity
- 7 gpm / 28 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FTDC
- Series
- 2
- Cavity
- T-52A
- Capacity
- 18 gpm / 70 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FTEC
- Series
- 3
- Cavity
- T-53A
- Capacity
- 12 gpm / 45 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FTFC
- Series
- 3
- Cavity
- T-53A
- Capacity
- 35 gpm / 140 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FTHC
- Series
- 4
- Cavity
- T-54A
- Capacity
- 80 gpm / 320 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics 4-way, 3-position meter-in proportional directional valve used for?▾
How do I read the Sun model codes FTCC, FTDC, FTEC, FTFC and FTHC?▾
What flow and cavity does each Sun FT proportional directional valve have?▾
How do I pilot the Sun FT meter-in proportional valve, and when is it fully shifted?▾
What pressure rating does the Sun FT proportional directional valve have?▾
What seal and body options does the Sun FT meter-in proportional valve have?▾
Which cavity does the Sun FT proportional directional valve fit?▾
What does the Sun FT proportional valve work with in the circuit?▾
How do I install the Sun FT cartridge and what torque applies?▾
How does the Sun FT hydraulic-piloted valve differ from the Sun FNUC electro-proportional directional valve?▾
Which Sun seal kits fit the FT proportional directional valve?▾
Do you stock the Sun Hydraulics FT proportional directional valve in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations