LL Overlapped Wound Fin Tubes

Tension-wound L-foot fins whose feet overlap one another, so the base tube is covered completely. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: LL Overlapped Wound Fin Tubes
- Construction: Tension wound, the foot of each fin overlaps the previous one to cover the tube completely
- Base tube material: CS, stainless TP316/316L, Cu-Ni
- Fin material: Aluminium; Copper
- Outside diameter: 19.05–38.1 mm
- Fin geometry: height 10–16; thickness 0.3–0.5
- Maximum service temperature: 155 °C typical maker limit (published 155–180 °C)
- Product type
- LL Overlapped Wound Fin Tubes
- Construction
- Tension wound, the foot of each fin overlaps the previous one to cover the tube completely
- Base tube material
- CS, stainless TP316/316L, Cu-Ni
- Fin material
- Aluminium; Copper
Product description
Tension-wound L-foot fins whose feet overlap one another, so the base tube is covered completely. The full cover protects the tube from the atmosphere, which suits air coolers in humid and coastal plants.
Specification
- Maximum service temperature: 155 °C typical maker limit (published 155–180 °C)
- Base tube OD (mm): 19–51
- Fin height (mm): 10–16
- Fin thickness (mm): 0.3–0.5
- Fin material: Aluminium, copper
- Bond type: Tension wound, the foot of each fin overlaps the previous one to cover the tube completely
- Atmospheric corrosion resistance: High (full foot coverage)
- Max length (m): 18
Materials
- Tube: CS, stainless TP316/316L, Cu-Ni
- Fins: Aluminium; Copper
Testing and documents
- Base tube per its spec
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Moderate-temperature air coolers where the foot overlap gives better tube coverage than single L
Sizes
4 sizes, each under its own Indus part number in the size table. The table lists typical sizes for the range; other sizes are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the fin type, material, height, thickness and fins per inch, and the bare length at each end. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | LL Overlapped Wound Fin Tubes |
| Construction | Tension wound, the foot of each fin overlaps the previous one to cover the tube completely |
Construction
| Parameter | Value |
|---|---|
| Base tube material | CS, stainless TP316/316L, Cu-Ni |
| Fin material | Aluminium; Copper |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 19.05–38.1 mm |
| Fin geometry | height 10–16; thickness 0.3–0.5 |
| Length | 18 m maximum single length |
| Size table | Typical sizes — other sizes on request |
Performance
| Parameter | Value |
|---|---|
| Maximum service temperature | 155 °C typical maker limit (published 155–180 °C) |
Quality
| Parameter | Value |
|---|---|
| Testing | Base tube per its spec |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Moderate-temperature air coolers where the foot overlap gives better tube coverage than single L |
Shipping & lead time
Sizes & part numbers
4 sizes- Indus part no.IH-TF-WF-LL-0190
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 44.45
- Fin height (mm)
- 12.7
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
- Indus part no.IH-TF-WF-LL-0254
- O.D. (mm)
- 25.4
- O.D. (in)
- 1
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 50.8
- Fin height (mm)
- 12.7
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
- Indus part no.IH-TF-WF-LL-0254-B
- O.D. (mm)
- 25.4
- O.D. (in)
- 1
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 57.15
- Fin height (mm)
- 15.88
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
- Indus part no.IH-TF-WF-LL-0381
- O.D. (mm)
- 38.1
- O.D. (in)
- 1 1/2
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 69.85
- Fin height (mm)
- 15.88
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Fin O.D. (mm) — Outside diameter over the fins in millimetres. Fin height (mm) — Height of the fin above the tube surface in millimetres. Fin thickness (mm) — Fin strip or plate thickness in millimetres. Fins per inch — Fin density in fins per inch; a band means any density in it can be made. Max. length (m) — Longest single length usually made, in metres; longer on request.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are LL overlapped wound fin tubes used for?▾
How are part numbers such as IH-TF-WF-LL-0254-B read?▾
What sizes do the LL Overlapped Wound Fin Tubes come in?▾
What fin materials and thickness do LL fins have?▾
What is the maximum service temperature of the LL Overlapped Wound Fin Tubes?▾
What materials are the LL Overlapped Wound Fin Tubes made from?▾
Which certificates apply to the LL Overlapped Wound Fin Tubes?▾
What do the LL Overlapped Wound Fin Tubes fit into?▾
What should I do to keep wound fin tubes clean in service?▾
How do LL fins differ from plain L-foot fins?▾
Can you export the LL Overlapped Wound Fin Tubes from Dubai?▾
Do you keep the LL Overlapped Wound Fin Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Heat-transfer tubes
Types of finned tubes: L, LL, KL, G-fin, extruded or welded?
Wound, embedded, extruded and welded fins differ in how the fin is held to the tube — and that bond sets the temperature, the corrosion protection and the price. How to choose a fin type for an air cooler, economiser or fired heater.
6 min read
Heat-transfer tubes
Extruded fin tube for coastal and offshore air coolers
Extruded aluminium fins cover the liner tube completely, which is why they are the usual choice for air coolers near the sea, offshore and in LNG and gas plants. How extruded tube is made, its limits, liner choices and sizes.
3 min read
Heat-transfer tubes
Finned tube fouling and cleaning in Gulf dust
Dust, sand and salt clog air-cooler fins across the Gulf every summer, just when the coolers are working hardest. How fouling builds up on finned tube, how to clean it without flattening the fins, and the design choices that make the next bundle easier to keep clean.