KL Knurled Wound Fin Tubes

L-foot aluminium or copper fins tension-wound onto a base tube that is knurled first, so the foot is pressed into the knurl. Made to API 661 / ISO 13706. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: KL Knurled Wound Fin Tubes
- Construction: Base tube knurled first, L-foot pressed into the knurl while tension winding
- Standards: API 661 / ISO 13706
- Base tube material: CS A179/A192/A106 B; Stainless TP304/316/321; Cu alloys B111
- Fin material: Aluminium 1050/1060; Copper
- Outside diameter: 19.05–38.1 mm
- Wall thickness: 1.65–3.0
- Fin geometry: height 6–50 (common 9.5–16); thickness 0.3–0.5
- Maximum service temperature: 260 °C typical maker limit (published 165–260 °C; confirm with maker per order)
- Product type
- KL Knurled Wound Fin Tubes
- Construction
- Base tube knurled first, L-foot pressed into the knurl while tension winding
- Base tube material
- CS A179/A192/A106 B; Stainless TP304/316/321; Cu alloys B111
- Fin material
- Aluminium 1050/1060; Copper
Product description
L-foot aluminium or copper fins tension-wound onto a base tube that is knurled first, so the foot is pressed into the knurl. The knurl gives a firmer bond than a plain L-foot, so KL fins hold at higher temperatures in air-cooled exchangers.
Specification
- Maximum service temperature: 260 °C typical maker limit (published 165–260 °C; confirm with maker per order)
- Base tube OD (mm): 15.88–165 (common 5/8–1 1/2 in)
- Base tube wall (mm): 1.65–3.0
- Fin height (mm): 6–50 (common 9.5–16)
- Fin thickness (mm): 0.3–0.5
- Fin material: Aluminium 1050/1060, copper
- Bond type: Base tube knurled first, L-foot pressed into the knurl while tension winding
Standards
API 661 / ISO 13706. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: CS A179/A192/A106 B; Stainless TP304/316/321; Cu alloys B111
- Fins: Aluminium 1050/1060; Copper
Testing and documents
- Base tube per its spec
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- ACHE services between L-fin and embedded-fin temperatures
Sizes
3 sizes, each under its own Indus part number in the size table. The table lists typical sizes for the range; other sizes are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the fin type, material, height, thickness and fins per inch, and the bare length at each end. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | KL Knurled Wound Fin Tubes |
| Construction | Base tube knurled first, L-foot pressed into the knurl while tension winding |
Compliance
| Parameter | Value |
|---|---|
| Standards | API 661 / ISO 13706 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | CS A179/A192/A106 B; Stainless TP304/316/321; Cu alloys B111 |
| Fin material | Aluminium 1050/1060; Copper |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 19.05–38.1 mm |
| Wall thickness | 1.65–3.0 |
| Fin geometry | height 6–50 (common 9.5–16); thickness 0.3–0.5 |
| Length | Random or fixed lengths; cut to length on request |
| Size table | Typical sizes — other sizes on request |
Performance
| Parameter | Value |
|---|---|
| Maximum service temperature | 260 °C typical maker limit (published 165–260 °C; confirm with maker per order) |
Quality
| Parameter | Value |
|---|---|
| Testing | Base tube per its spec |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | ACHE services between L-fin and embedded-fin temperatures |
Shipping & lead time
Sizes & part numbers
3 sizes- Indus part no.IH-TF-WF-KL-0190
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 44.45
- Fin height (mm)
- 12.7
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
- Indus part no.IH-TF-WF-KL-0254
- O.D. (mm)
- 25.4
- O.D. (in)
- 1
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 57.15
- Fin height (mm)
- 15.88
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
- Indus part no.IH-TF-WF-KL-0381
- O.D. (mm)
- 38.1
- O.D. (in)
- 1 1/2
- Wall (mm)
- 1.65–3.0
- Fin O.D. (mm)
- 69.85
- Fin height (mm)
- 15.88
- Fin thickness (mm)
- 0.41
- Fins per inch
- 6–12
- Max. length (m)
- 18
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Fin O.D. (mm) — Outside diameter over the fins in millimetres. Fin height (mm) — Height of the fin above the tube surface in millimetres. Fin thickness (mm) — Fin strip or plate thickness in millimetres. Fins per inch — Fin density in fins per inch; a band means any density in it can be made. Max. length (m) — Longest single length usually made, in metres; longer on request.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are KL knurled wound fin tubes used for?▾
How are the part numbers such as IH-TF-WF-KL-0190 read?▾
What sizes do the KL Knurled Wound Fin Tubes come in?▾
What fin height and thickness do KL fins have?▾
What is the maximum service temperature of the KL Knurled Wound Fin Tubes?▾
What materials are the KL Knurled Wound Fin Tubes made from?▾
Which standards and certificates apply to the KL Knurled Wound Fin Tubes?▾
What do the KL Knurled Wound Fin Tubes fit into?▾
How is the bond made on the KL Knurled Wound Fin Tubes?▾
How do KL fins differ from plain L and LL wound fins?▾
Can you export the KL Knurled Wound Fin Tubes from Dubai?▾
Do you keep the KL Knurled Wound Fin Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog