Skip to content
IH-TF-WF-L

L-Foot Tension-Wound Fin Tubes

Wound Fin Tubes (L / LL / KL)Ex-stock · delivery in 3 days
L-foot wound fin tubes close up, thin fins wrapped tightly round each tube
VIEW 01·L-foot wound fin tubes close up, thin fins wrapped tightly round each tube

Aluminium or copper fin strip with an L-shaped foot, tension-wound onto the base tube so each foot sits on the tube surface. Made to API 661 / ISO 13706, ASME SA210. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.

Key features

  • Product type: L-Foot Tension-Wound Fin Tubes
  • Construction: Tension wound with an L-shaped foot; contact pressure only, which loosens with time and temperature cycling
  • Standards: API 661 / ISO 13706, ASME SA210
  • Base tube material: Unlimited: CS, stainless, copper alloys
  • Fin material: Aluminium 1100-O; Aluminium alloy (5xxx); Copper
  • Outside diameter: 15.88–38.1 mm
  • Wall thickness: 1.65–3.0
  • Fin geometry: height 9.5–15.9 (3/8–5/8 in); thickness 0.38 (0.015 in) typical; 0.38–0.51; density 4–12 FPI (157–472 fins/m)
  • Maximum service temperature: 120 °C conservative; 120–150 °C typical maker limit (bond loosens with thermal cycling)
Product type
L-Foot Tension-Wound Fin Tubes
Construction
Tension wound with an L-shaped foot; contact pressure only, which loosens with time and temperature cycling
Base tube material
Unlimited: CS, stainless, copper alloys
Fin material
Aluminium 1100-O; Aluminium alloy (5xxx); Copper
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

Aluminium or copper fin strip with an L-shaped foot, tension-wound onto the base tube so each foot sits on the tube surface. The most economical air-cooler fin, for moderate temperatures; the bond is contact pressure only, so the ends are banded to stop the fins unwinding.

Specification

  • Maximum service temperature: 120 °C conservative; 120–150 °C typical maker limit (bond loosens with thermal cycling)
  • Base tube OD (mm): 15.88–38.1 (5/8–1 1/2 in)
  • Edge-tension (I-type) base OD (mm): 12.7–50.8 (1/2–2 in)
  • Base tube wall (mm): 1.65–3.0
  • Fin height (mm): 9.5–15.9 (3/8–5/8 in)
  • Fin thickness (mm): 0.38 (0.015 in) typical; 0.38–0.51
  • Fin density: 4–12 FPI (157–472 fins/m)
  • Fin material: Aluminium 1100-O or 5052-type alloy, copper; edge-tension also CS and stainless
  • Bond type: Tension wound with an L-shaped foot; contact pressure only, which loosens with time and temperature cycling
  • Fin end retention: API 661 calls for cast zinc bands at tube ends to stop footed fins unwinding
  • Max length (m): 18

Standards

API 661 / ISO 13706, ASME SA210. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.

Materials

  • Tube: Unlimited: CS, stainless, copper alloys
  • Fins: Aluminium 1100-O; Aluminium alloy (5xxx); Copper

Testing and documents

  • Base tube per its spec; no fin bond test standard found
  • Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan

Where it is used

  • Low-temperature air coolers, lube-oil and jacket-water coolers, HVAC/enclosure heaters

Sizes

5 sizes, each under its own Indus part number in the size table. The table lists typical sizes for the range; other sizes are made on request.

Ordering

Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the fin type, material, height, thickness and fins per inch, and the bare length at each end. We quote with the mill certificates and the inspection you need.

Identification

ParameterValue
Product typeL-Foot Tension-Wound Fin Tubes
ConstructionTension wound with an L-shaped foot; contact pressure only, which loosens with time and temperature cycling

Compliance

ParameterValue
StandardsAPI 661 / ISO 13706, ASME SA210

Construction

ParameterValue
Base tube materialUnlimited: CS, stainless, copper alloys
Fin materialAluminium 1100-O; Aluminium alloy (5xxx); Copper

Dimensions

ParameterValue
Outside diameter15.88–38.1 mm
Wall thickness1.65–3.0
Fin geometryheight 9.5–15.9 (3/8–5/8 in); thickness 0.38 (0.015 in) typical; 0.38–0.51; density 4–12 FPI (157–472 fins/m)
Length18 m maximum single length
Size tableTypical sizes — other sizes on request

Performance

ParameterValue
Maximum service temperature120 °C conservative; 120–150 °C typical maker limit (bond loosens with thermal cycling)

Quality

ParameterValue
TestingBase tube per its spec; no fin bond test standard found
CertificationMill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement

Application

ParameterValue
Typical servicesLow-temperature air coolers, lube-oil and jacket-water coolers, HVAC/enclosure heaters

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

From the blog

Written about this part

RELATED · OFTEN PAIRED WITH