Dinamic Oil Gearbox Oil Cooling Units — URO/W Oil/Water and URO/A Oil/Air, 4 to 50 kW

Dinamic Oil URO/W oil/water and URO/A oil/air cooling units for planetary gearboxes: 17 sizes, 4 to 50 kW, motor-driven pump, gauge, thermometer and thermostat. From Indus Hydraulics, authorised Dinamic Oil distributor, UAE.
Key features
- Product type: Gearbox oil cooling unit
- Series: Dinamic Oil URO/W, URO/A
- Execution: Independent unit: pump, heat exchanger, instruments
- Motor / input: Three-phase 230/400 V 50 Hz four-pole motors
- Product type
- Gearbox oil cooling unit
- Series
- Dinamic Oil URO/W, URO/A
Product description
A planetary gearbox can transmit more power than it can shed as heat. When the power in continuous duty exceeds the gearbox's thermal power — a mixer, conveyor, mill or travel drive running all day, or any gearbox in a Gulf summer — the oil overheats long before the gears are at their rating. Dinamic Oil's independent cooling units circulate the gearbox oil through a heat exchanger and back, removing up to 50 kW; larger units are engineered on request.
Indus Hydraulics is an authorised Dinamic Oil distributor and supplies direct from Dinamic Oil's factory in Bomporto, Italy.
Oil/water units — URO/W
Seven sizes, 4 to 50 kW with water at 20 °C: a water/oil heat exchanger, a motor-driven gear pump (four-pole B5 motor, 230/400 V 50 Hz three-phase, Viton seals), a 0–16 bar gauge between pump and exchanger, and a 0–120 °C thermometer at the exchanger outlet.
Oil/air units — URO/A
Ten sizes, 5 to 46 kW with air at 20 °C: an air/oil exchanger with fan and an adjustable, pre-wired 0–90 °C thermostat, a motor-driven screw pump (four-pole B3/B5 motor, 230/400 V 50 Hz), gauge and thermometer. No water supply is needed, which suits remote sites — but the rating falls as the air gets hotter, so size an air unit for the real summer air temperature.
Options
A filter on the return to the gearbox (recommended), a minimum-pressure switch between pump and exchanger, and an electric flow switch for full control of the oil flow. The table lists each unit's capacity, pump and fan motors, oil flow, water or air flow and overall dimensions A × B × C in millimetres.
Sizing
The unit has to remove the difference between the power lost in the gearbox and the heat the housing sheds by itself. Tell us the gearbox model, the transmitted power and duty, the mounting position and the ambient (or cooling-water) temperature, and we will size the unit with Dinamic Oil and confirm the oil connections on the gearbox.
Identification
| Parameter | Value |
|---|---|
| Product type | Gearbox oil cooling unit |
| Series | Dinamic Oil URO/W, URO/A |
| Execution | Independent unit: pump, heat exchanger, instruments |
Hydraulics
| Parameter | Value |
|---|---|
| Oil flow | 16 to 80 L/min |
Construction
| Parameter | Value |
|---|---|
| Motor / input | Three-phase 230/400 V 50 Hz four-pole motors |
Compliance
| Parameter | Value |
|---|---|
| Rating basis | Capacity at 20 °C water (URO/W) or 20 °C air (URO/A) |
Supply
| Parameter | Value |
|---|---|
| Made in | Italy (Dinamic Oil S.p.A., Bomporto) |
| Supply | Authorised distributor, direct from the factory |
Shipping & lead time
Sizes & part numbers
17 sizes- Indus part no.IH-DO-COOL-UROW4
- Description
- URO/W 4 — 4 kW at 20 °C water; pump motor 0.37 kW; water 8 L/min
- Max flow (L/min)
- 16
- A (mm)
- 500
- B (mm)
- 350
- C (mm)
- 400
- Indus part no.IH-DO-COOL-UROW6
- Description
- URO/W 6 — 6 kW at 20 °C water; pump motor 0.37 kW; water 10 L/min
- Max flow (L/min)
- 16
- A (mm)
- 500
- B (mm)
- 350
- C (mm)
- 400
- Indus part no.IH-DO-COOL-UROW9
- Description
- URO/W 9 — 9 kW at 20 °C water; pump motor 0.55 kW; water 16 L/min
- Max flow (L/min)
- 16
- A (mm)
- 500
- B (mm)
- 350
- C (mm)
- 400
- Indus part no.IH-DO-COOL-UROW13
- Description
- URO/W 13 — 13 kW at 20 °C water; pump motor 1.1 kW; water 25 L/min
- Max flow (L/min)
- 30
- A (mm)
- 500
- B (mm)
- 350
- C (mm)
- 400
- Indus part no.IH-DO-COOL-UROW21
- Description
- URO/W 21 — 21 kW at 20 °C water; pump motor 1.5 kW; water 40 L/min
- Max flow (L/min)
- 30
- A (mm)
- 500
- B (mm)
- 400
- C (mm)
- 450
- Indus part no.IH-DO-COOL-UROW31
- Description
- URO/W 31 — 31 kW at 20 °C water; pump motor 2.2 kW; water 50 L/min
- Max flow (L/min)
- 56
- A (mm)
- 720
- B (mm)
- 510
- C (mm)
- 520
- Indus part no.IH-DO-COOL-UROW50
- Description
- URO/W 50 — 50 kW at 20 °C water; pump motor 3.0 kW; water 80 L/min
- Max flow (L/min)
- 80
- A (mm)
- 730
- B (mm)
- 520
- C (mm)
- 520
- Indus part no.IH-DO-COOL-UROA5
- Description
- URO/A 5 — 5 kW at 20 °C air; pump motor 1.5 kW; fan 0.12 kW, 900 m³/h
- Max flow (L/min)
- 30
- A (mm)
- 660
- B (mm)
- 430
- C (mm)
- 700
Show all 17 sizesShow fewer sizes
- Indus part no.IH-DO-COOL-UROA7
- Description
- URO/A 7 — 7 kW at 20 °C air; pump motor 1.5 kW; fan 0.12 kW, 1,300 m³/h
- Max flow (L/min)
- 30
- A (mm)
- 710
- B (mm)
- 510
- C (mm)
- 700
- Indus part no.IH-DO-COOL-UROA10
- Description
- URO/A 10 — 10 kW at 20 °C air; pump motor 1.5 kW; fan 0.18 kW, 2,750 m³/h
- Max flow (L/min)
- 30
- A (mm)
- 710
- B (mm)
- 510
- C (mm)
- 830
- Indus part no.IH-DO-COOL-UROA13
- Description
- URO/A 13 — 13 kW at 20 °C air; pump motor 1.5 kW; fan 0.23 kW, 2,750 m³/h
- Max flow (L/min)
- 30
- A (mm)
- 710
- B (mm)
- 510
- C (mm)
- 830
- Indus part no.IH-DO-COOL-UROA16
- Description
- URO/A 16 — 16 kW at 20 °C air; pump motor 2.2 kW; fan 0.23 kW, 3,500 m³/h
- Max flow (L/min)
- 56
- A (mm)
- 710
- B (mm)
- 510
- C (mm)
- 1010
- Indus part no.IH-DO-COOL-UROA21
- Description
- URO/A 21 — 21 kW at 20 °C air; pump motor 2.2 kW; fan 0.56 kW, 6,300 m³/h
- Max flow (L/min)
- 56
- A (mm)
- 800
- B (mm)
- 500
- C (mm)
- 1200
- Indus part no.IH-DO-COOL-UROA26
- Description
- URO/A 26 — 26 kW at 20 °C air; pump motor 3 kW; fan 0.56 kW, 7,450 m³/h
- Max flow (L/min)
- 56
- A (mm)
- 800
- B (mm)
- 500
- C (mm)
- 1265
- Indus part no.IH-DO-COOL-UROA30
- Description
- URO/A 30 — 30 kW at 20 °C air; pump motor 3 kW; fan 0.56 kW, 7,450 m³/h
- Max flow (L/min)
- 80
- A (mm)
- 800
- B (mm)
- 500
- C (mm)
- 1265
- Indus part no.IH-DO-COOL-UROA40
- Description
- URO/A 40 — 40 kW at 20 °C air; pump motor 2.2 kW; fan 0.9 kW, 9,500 m³/h
- Max flow (L/min)
- 56
- A (mm)
- 1010
- B (mm)
- 600
- C (mm)
- 1350
- Indus part no.IH-DO-COOL-UROA46
- Description
- URO/A 46 — 46 kW at 20 °C air; pump motor 3 kW; fan 0.9 kW, 9,500 m³/h
- Max flow (L/min)
- 80
- A (mm)
- 1010
- B (mm)
- 600
- C (mm)
- 1350
Description — What this part number is, as the manufacturer lists it. Max flow — Maximum flow capacity in litres per minute, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. A — Dimension A on the manufacturer dimension drawing. B — Dimension B on the manufacturer dimension drawing. C — Dimension C on the manufacturer dimension drawing. Ask us for the dimension drawing if you need it stamped.
What are Dinamic Oil URO/W and URO/A gearbox oil cooling units used for?▾
How do I read URO/W 13 and URO/A 13 cooling unit codes?▾
What sizes do the URO/W and URO/A units come in?▾
How do I size a gearbox oil cooler?▾
What are the URO/W and URO/A cooling capacities based on?▾
What is in a URO/W oil/water unit?▾
What is in a URO/A oil/air unit?▾
Water or air cooling for a planetary gearbox?▾
What options can be added to a gearbox oil cooling unit?▾
When does a planetary gearbox need an oil cooler?▾
Are Dinamic Oil URO cooling units genuine?▾
Do you supply Dinamic Oil URO cooling units from Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog