Bijur Delimon SureFire II Three-Phase Lubrication Pumps

Bijur Delimon SureFire II Three-Phase Lubrication Pumps: 2 part numbers, for SLR, PDI systems; oil; 3 to 6 L reservoirs. The three-phase SureFire II runs the same gear pump and reservoir range as the single-phase unit from the machine's 230/480 or 330/575 VAC three-phase supply, for plants that do not want a separate single-phase feed to the lubricator. From Indus Hydraulics, authorised Bijur Delimon distributor for the Middle East, supplied direct from the manufacturer.
Key features
- Product type: Electric lubrication pump
- Series: Bijur Delimon SureFire II Three-Phase Lubrication Pumps
- Drive: Electric motor
- Lubrication system: SLR, PDI
- Lubricant: Oil
- Reservoir: 3 to 6 L
- Output: 500 cc/min
- Max pressure: 300 psi (21 bar) to 450 psi (31 bar)
- Supply voltage: 230/480VAC, 330/575VAC
- Product type
- Electric lubrication pump
- Drive
- Electric motor
- Lubrication system
- SLR, PDI
- Lubricant
- Oil
Product description
The three-phase SureFire II runs the same gear pump and reservoir range as the single-phase unit from the machine's 230/480 or 330/575 VAC three-phase supply, for plants that do not want a separate single-phase feed to the lubricator.
Indus Hydraulics is an authorised Bijur Delimon distributor for the Middle East and supplies genuine units direct from the manufacturer, with the maker's datasheets and manuals.
How it works
Choose the distribution system (SLR or PDI), reservoir size and material, monitoring and fill exactly as on the single-phase pump; the order code adds the three-phase motor voltage. CSA-marked versions are available.
Range
2 listed part numbers plus versions configured to order from 5,368 order codes (SFX…) — systems SLR, PDI; lubricants Oil; reservoirs 3 to 6 L; supply 230/480VAC, 330/575VAC; output 500 cc/min; maximum pressure 300 psi (21 bar) to 450 psi (31 bar). The size table gives each part number's data.
Row descriptions are Bijur Delimon's own: LS / LLS level or low-level switch, HLS high-level switch, PG pressure gauge, PS pressure switch, CNTL controller, P&M pump and motor, SLR single-line resistance, PDI positive-displacement injector, PROG progressive. The columns give each part number's published data.
Where it is used
- large machine tools and presses
- steel and paper-mill auxiliaries
- machines with three-phase-only control panels
Choosing the pump
Start from the distribution system the pump has to drive — SLR meter units, PDI injectors, progressive dividers, Dualine valves or direct multi-line feeds — then the lubricant: oil grade in cSt, or grease NLGI class (fluid grease for PDI). Size the reservoir for the refill interval you want, match the supply voltage and enclosure to the machine, and decide how the cycle is controlled: an integral timer or controller, an external controller, or the machine PLC. Level and pressure switches let the control system prove each cycle.
Complete systems
A pump is one part of a lubrication system. With it we supply the Bijur Delimon distribution — meter units, injectors, divider valves or Dualine valves — and the tubing, fittings, controllers and monitoring to match, sized to the number of points and the lubricant. Send us the machine and the lubrication points and we propose the full system.
Order code — SureFire II 3-Phase
The order code is SFX followed by one code from each position below, in order. Bijur Delimon lists 5,368 valid combinations; send us the code (or the options) and we confirm it with the manufacturer before quoting.
| Position | Option | Code | Meaning |
|---|---|---|---|
| 1 | Reservoir Capacity | 3 | 3L - 3 liter |
| 6 | 6L - 6 liter | ||
| 12 | 12L - 12 liter | ||
| 30 | 30L - 30 liter | ||
| 2 | Reservoir Material | P | Plastic - Luran (Blue Tint) |
| M | Metal - Painted Steel | ||
| 3 | Distribution System | A | SLR - 130psi Relief Valve |
| B | PDI - 450psi Relief Valve | ||
| D | MP - 270psi Relief Valve | ||
| 4 | Lubricant | S | Oil 20-1500 cSt |
| G | Grease 000-00 (40,000 cSt MAX) | ||
| 5 | Level Monitoring | X | None |
| D | Standard - DIN Type | ||
| E | Standard - M12 Type | ||
| F | Option - M12 Type | ||
| G | Option - DIN Type | ||
| 6 | Pressure Monitoring | X | None |
| G | Pressure Gauge | ||
| 7 | Method of Fill | N | Standard filler cap (Oil version has integrated strainer) |
| A | ISO 7241 Quick coupling male (plug) | ||
| B | Cnomo Approved quick coupling male | ||
| C | Quick coupling male for grease | ||
| 8 | Flow Regulation | X | None |
| E | Pressure Bypass | ||
| F | Flow Bypass | ||
| G | Pressure Bypass with Return Filter | ||
| H | Flow Bypass with Return Filter | ||
| 9 | Electrical Connector | D | Direct Connect to 3phase Motor |
| 10 | Voltage | F | 230/480VAC,50/60 Hz,0.5amps Three Phase (250cc/Min-60Hz) |
| E | 230/480VAC,50/60 Hz,0.5amps Three Phase (500cc/Min-60Hz) |
Examples of valid codes: SFX3PBSDGNXDE, SFX6PBSDGNXDE, SFX12MBSDGNXDE.
Spare parts
Genuine Bijur Delimon service parts and kits for this range are listed by part number on Bijur Delimon SureFire II Service Parts and Kits.
Documents
Bijur Delimon's flyers for this range are in the Downloads tab.
Identification
| Parameter | Value |
|---|---|
| Product type | Electric lubrication pump |
| Series | Bijur Delimon SureFire II Three-Phase Lubrication Pumps |
| Drive | Electric motor |
Application
| Parameter | Value |
|---|---|
| Lubrication system | SLR, PDI |
| Lubricant | Oil |
| Viscosity / NLGI range | 20-1500 cSt |
Performance
| Parameter | Value |
|---|---|
| Reservoir | 3 to 6 L |
| Output | 500 cc/min |
| Max pressure | 300 psi (21 bar) to 450 psi (31 bar) |
Electrical
| Parameter | Value |
|---|---|
| Supply voltage | 230/480VAC, 330/575VAC |
| IP rating | IP54 |
| Monitoring | low-level switch, pressure gauge |
Connections
| Parameter | Value |
|---|---|
| Outlet thread | 1/8NPT, 1/4BSPP |
| Fill connection | FILL CAP |
Environment
| Parameter | Value |
|---|---|
| Operating temperature | 5°C-40°C |
| Approvals | CE, CSA |
Ordering
| Parameter | Value |
|---|---|
| Order code | SFX… (5,368 codes) |
| Supply | Genuine Bijur Delimon, direct from the manufacturer (authorised distributor) |
Shipping & lead time
Sizes & part numbers
2 sizes- Indus part no.IH-BD-SFX29017
- Description
- SFX29017 — SUREFIRE II 6L SLR LS PG FB 230/480VAC
- System
- SLR
- Lubricant
- Oil 20-1500 cSt
- Reservoir
- 6L
- Supply
- 230/480VAC, 3 ph, 50/60 Hz
- Output
- 500cc/min
- Max pressure
- 300 psi (21 bar)
- Outlet
- 1/8NPT
- Monitoring
- low-level switch, pressure gauge
- Indus part no.IH-BD-SFX71307
- Description
- SFX71307 — SUREFIRE II 3L PDI LS PG PB 330/575VAC CSA
- System
- PDI
- Lubricant
- Oil 20-1500 cSt
- Reservoir
- 3L
- Supply
- 330/575VAC, 3 ph, 50/60 Hz
- Output
- 500cc/min
- Max pressure
- 450 psi (31 bar)
- Outlet
- 1/4BSPP
- Monitoring
- low-level switch, pressure gauge
Description — What this part number is, as the manufacturer lists it. System — Lubrication system the pump feeds — SLR (single-line resistance), PDI (positive-displacement injector), progressive, Dualine or multi-line — as published. Lubricant — Oil or grease, with the viscosity or NLGI range the pump handles, as published. Reservoir — Reservoir capacity in the unit the maker publishes it. Supply — Motor or control voltage, phase and frequency, as published. Output — Lubricant output per cycle or per minute, as published. Max pressure — Maximum pressure as the maker publishes it, in psi and bar. Outlet — Outlet port thread, as published. Monitoring — Level switch, pressure switch, gauge or controller the part number includes, as published.
What are Bijur Delimon SureFire II Three-Phase Lubrication Pumps?▾
How do I read the order code for Bijur Delimon SureFire II Three-Phase Lubrication Pumps?▾
Which part numbers and versions does Bijur Delimon SureFire II Three-Phase Lubrication Pumps cover?▾
How do I choose the right SureFire II Three-Phase Lubrication Pumps for my machine?▾
What pressure, output and reservoir ratings do Bijur Delimon SureFire II Three-Phase Lubrication Pumps have?▾
What is a PDI lubrication system, and is Bijur Delimon SureFire II Three-Phase Lubrication Pumps used in one?▾
Which lubricants and viscosities can Bijur Delimon SureFire II Three-Phase Lubrication Pumps handle?▾
What approvals and enclosure rating do Bijur Delimon SureFire II Three-Phase Lubrication Pumps have?▾
Can Bijur Delimon SureFire II Three-Phase Lubrication Pumps be supplied as part of a complete lubrication system?▾
Do you supply spare parts and service kits for Bijur Delimon SureFire II Three-Phase Lubrication Pumps?▾
How do Bijur Delimon SureFire II Three-Phase Lubrication Pumps differ from Bijur Delimon SureFire II Single-Phase Lubrication Pumps (SLR and PDI)?▾
Do you keep Bijur Delimon SureFire II Three-Phase Lubrication Pumps in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog