Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators

Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators: 16 part numbers, for SLR systems; oil; 1 to 4 L reservoirs. TM-5 and TMD-5 are compact, motor-driven piston oilers with adjustable discharge for SLR systems of roughly 10 to 50 points. From Indus Hydraulics, authorised Bijur Delimon distributor for the Middle East, supplied direct from the manufacturer.
Key features
- Product type: Electric lubrication pump
- Series: Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators
- Drive: Electric motor
- Lubrication system: SLR
- Lubricant: Oil
- Reservoir: 1 to 4 L
- Output: FACTORY SET 3.2cc (2.5-5cc/cycle), 1-5cc/cycle, FACTORY SET 1cc (1-5cc/cycle), FACTORY SET 1.8cc (1-5cc/cycle), FACTORY SET 1.2cc (1-5cc/cycle)
- Max pressure: 60 psi (4 bar)
- Supply voltage: 115VAC, 115/230VAC, 24VDC
- Product type
- Electric lubrication pump
- Drive
- Electric motor
- Lubrication system
- SLR
- Lubricant
- Oil
Product description
TM-5 and TMD-5 are compact, motor-driven piston oilers with adjustable discharge for SLR systems of roughly 10 to 50 points.
Indus Hydraulics is an authorised Bijur Delimon distributor for the Middle East and supplies genuine units direct from the manufacturer, with the maker's datasheets and manuals.
How it works
An internal gear-reduction motor fixes the cycle time; the shot volume is set on the marked indicator rod. Both can be cycled by hand with the feed knob, and the TMD-5 includes a low-level switch.
Range
16 listed part numbers — systems SLR; lubricants Oil; reservoirs 1 to 4 L; supply 115VAC, 115/230VAC, 24VDC; output FACTORY SET 3.2cc (2.5-5cc/cycle), 1-5cc/cycle, FACTORY SET 1cc (1-5cc/cycle), FACTORY SET 1.8cc (1-5cc/cycle), FACTORY SET 1.2cc (1-5cc/cycle); maximum pressure 60 psi (4 bar). The size table gives each part number's data.
Row descriptions are Bijur Delimon's own: LS / LLS level or low-level switch, HLS high-level switch, PG pressure gauge, PS pressure switch, CNTL controller, P&M pump and motor, SLR single-line resistance, PDI positive-displacement injector, PROG progressive. The columns give each part number's published data.
Where it is used
- small machine tools
- woodworking and printing machines
- retrofit of older one-shot systems
Choosing the pump
Start from the distribution system the pump has to drive — SLR meter units, PDI injectors, progressive dividers, Dualine valves or direct multi-line feeds — then the lubricant: oil grade in cSt, or grease NLGI class (fluid grease for PDI). Size the reservoir for the refill interval you want, match the supply voltage and enclosure to the machine, and decide how the cycle is controlled: an integral timer or controller, an external controller, or the machine PLC. Level and pressure switches let the control system prove each cycle.
Complete systems
A pump is one part of a lubrication system. With it we supply the Bijur Delimon distribution — meter units, injectors, divider valves or Dualine valves — and the tubing, fittings, controllers and monitoring to match, sized to the number of points and the lubricant. Send us the machine and the lubrication points and we propose the full system.
Spare parts
Genuine Bijur Delimon service parts and kits for this range are listed by part number on Bijur Delimon TM-5 and TMD-5 Lubricator Service Parts.
Documents
Bijur Delimon's datasheets and service sheets for this range are in the Downloads tab.
Identification
| Parameter | Value |
|---|---|
| Product type | Electric lubrication pump |
| Series | Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators |
| Drive | Electric motor |
Application
| Parameter | Value |
|---|---|
| Lubrication system | SLR |
| Lubricant | Oil |
| Viscosity / NLGI range | 150-8000 SSU, 27-1700 cSt |
Performance
| Parameter | Value |
|---|---|
| Reservoir | 1 to 4 L |
| Output | FACTORY SET 3.2cc (2.5-5cc/cycle), 1-5cc/cycle, FACTORY SET 1cc (1-5cc/cycle), FACTORY SET 1.8cc (1-5cc/cycle), FACTORY SET 1.2cc (1-5cc/cycle) |
| Max pressure | 60 psi (4 bar) |
Electrical
| Parameter | Value |
|---|---|
| Supply voltage | 115VAC, 115/230VAC, 24VDC |
| IP rating | IP52 |
| Monitoring | low-level switch |
Connections
| Parameter | Value |
|---|---|
| Outlet thread | 5/16-24, 1/8NPT |
| Fill connection | CAP, FILL CAP |
Environment
| Parameter | Value |
|---|---|
| Operating temperature | 5°C-40°C |
Ordering
| Parameter | Value |
|---|---|
| Supply | Genuine Bijur Delimon, direct from the manufacturer (authorised distributor) |
Shipping & lead time
Sizes & part numbers
16 sizes- Indus part no.IH-BD-34819
- Description
- 34819 — TM5 115/230VAC SLR LS PF WA 27.7MIN
- System
- SLR
- Lubricant
- Oil 150-8000 SSU
- Reservoir
- 1L
- Supply
- 115VAC, 1 ph, 50/60 Hz
- Output
- FACTORY SET 3.2cc (2.5-5cc/cycle)
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26061
- Description
- 26061 — TMD5 2L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26062
- Description
- 26062 — TMD5 2L 115/230VAC SLR LS 27.7MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26201
- Description
- 26201 — TMD5 2L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- FACTORY SET 1cc (1-5cc/cycle)
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26202
- Description
- 26202 — TMD5 2L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- FACTORY SET 1.8cc (1-5cc/cycle)
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26203
- Description
- 26203 — TMD5 2L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- FACTORY SET 1.2cc (1-5cc/cycle)
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26350-1
- Description
- 26350-1 — TMD5 2L 115/230VAC SLR LS 5.3MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26350-2
- Description
- 26350-2 — TMD5 2L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
Show all 16 sizesShow fewer sizes
- Indus part no.IH-BD-26350-3
- Description
- 26350-3 — TMD5 2L 115/230VAC SLR LS 13.3MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26350-4
- Description
- 26350-4 — TMD5 2L 115/230VAC SLR LS 27.7MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26350-5
- Description
- 26350-5 — TMD5 2L 115/230VAC SLR LS 53.3MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26350-6
- Description
- 26350-6 — TMD5 2L 115/230VAC SLR LS 106.7MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26517-1
- Description
- 26517-1 — TMD5 4L 115/230VAC SLR LS 5.3MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 4L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26517-2
- Description
- 26517-2 — TMD5 4L 115/230VAC SLR LS 8.9MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 4L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-26517-6
- Description
- 26517-6 — TMD5 4L 115/230VAC SLR LS 106.7MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 4L
- Supply
- 115/230VAC, 1 ph, 50/60 Hz
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 5/16-24
- Monitoring
- low-level switch
- Indus part no.IH-BD-32295
- Description
- 32295 — TMD5 2L 24VDC LS 27.7MIN
- System
- SLR
- Lubricant
- Oil 27-1700 cSt
- Reservoir
- 2L
- Supply
- 24VDC
- Output
- 1-5cc/cycle
- Max pressure
- 60 psi (4 bar)
- Outlet
- 1/8NPT
- Monitoring
- low-level switch
Description — What this part number is, as the manufacturer lists it. System — Lubrication system the pump feeds — SLR (single-line resistance), PDI (positive-displacement injector), progressive, Dualine or multi-line — as published. Lubricant — Oil or grease, with the viscosity or NLGI range the pump handles, as published. Reservoir — Reservoir capacity in the unit the maker publishes it. Supply — Motor or control voltage, phase and frequency, as published. Output — Lubricant output per cycle or per minute, as published. Max pressure — Maximum pressure as the maker publishes it, in psi and bar. Outlet — Outlet port thread, as published. Monitoring — Level switch, pressure switch, gauge or controller the part number includes, as published.
What are Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators?▾
What does an Indus part number such as IH-BD-34819 mean for Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators?▾
Which part numbers and versions does Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators cover?▾
How do I choose the right TM-5 and TMD-5 Automatic Oil Lubricators for my machine?▾
What pressure, output and reservoir ratings do Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators have?▾
What is a SLR lubrication system, and is Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators used in one?▾
Which lubricants and viscosities can Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators handle?▾
What approvals and enclosure rating do Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators have?▾
Can Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators be supplied as part of a complete lubrication system?▾
Do you supply spare parts and service kits for Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators?▾
How do Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators differ from Bijur Delimon TM-1 Automatic Oil Lubricators?▾
Do you keep Bijur Delimon TM-5 and TMD-5 Automatic Oil Lubricators in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog