Sun Hydraulics Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve — MWEG, MWGG, MWIG, Series 2 to 4

Sun Hydraulics load-reactive load control valve, 4.5:1 pilot ratio: MWEG, MWGG, MWIG, series 2 to 4, 30 gpm to 120 gpm (120 L/min to 480 L/min), T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Load-Reactive Load Control Valve
- Capacity: 30 gpm to 120 gpm (120 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-22A, T-23A, T-24A
- Valve function
- Load-Reactive Load Control Valve
- Series (frame sizes)
- 2 to 4
- Cavity
- T-22A, T-23A, T-24A
Product description
A 3-port load control valve that works like a counterbalance valve: an integral check gives free flow into the actuator (port 2 to port 1) and a pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 lowers its setting by the pilot ratio. It seats as a poppet for tight holding and meters as a spool for smooth lowering.
Sizes and cavities
Sun Hydraulics builds this valve in 3 sizes. The series sets the cavity it screws into and its flow capacity:
- MWEG — series 2, T-22A cavity, 30 gpm (120 L/min)
- MWGG — series 3, T-23A cavity, 60 gpm (240 L/min)
- MWIG — series 4, T-24A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 4.5:1
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 5 drops/min. (0,3 cc/min)
- Reseat: ≥77% of setting
- Check cracking pressure: 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for MWIG; a size may add or drop a choice):
- Control: L — Standard Screw Adjustment
- Setting range: H — 1000 - 4000 psi (70 - 280 bar), 3000 psi (210 bar) Standard Setting, J — 2000 - 5000 psi (140 - 350 bar), 3000 psi (210 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be L; If the modifier is /LH, the control must be L.
Selection notes
- Set it at least 1.3 times the highest load-induced pressure, or 1.5 times where the setting is below 2,000 psi (140 bar).
- Back-pressure at port 2 adds to the effective setting, multiplied by one plus the pilot ratio — the vented versions avoid this.
- Turning the adjusting screw clockwise lowers the setting.
Where it is used
Load holding on large cylinders and motors in mobile and industrial machines, where higher flow is needed.
Installation and seal kits
Valve hex 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example MWIGLHN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 30 gpm to 120 gpm (120 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Pilot ratio | 4.5:1 |
| Setting range | H — 1000 - 4000 psi (70 - 280 bar), 3000 psi (210 bar) Standard Setting, J — 2000 - 5000 psi (140 - 350 bar), 3000 psi (210 bar) Standard Setting |
| Max leakage | 5 drops/min. (0,3 cc/min) |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006 |
Identification
| Parameter | Value |
|---|---|
| Valve function | Load-Reactive Load Control Valve |
| Series (frame sizes) | 2 to 4 |
| Cavity | T-22A, T-23A, T-24A |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Shipping & lead time
Sizes & part numbers
3 sizes- Sun Hydraulics part no.MWEG
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.MWGG
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.MWIG
- Series
- 4
- Cavity
- T-24A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEG, MWGG, MWIG) and what does it do?▾
How do I read the Sun model code for the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEG, MWGG, MWIG)?▾
What sizes and flow capacities does the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve come in?▾
What pressure and setting range does the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve have?▾
Which seal and material options does the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve come with?▾
How is the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve adjusted, and which control options are offered?▾
Which seal kit fits the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEG, MWGG, MWIG)?▾
Which cavity and installation torque does the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve need?▾
Where is the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve used?▾
How does the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve differ from the Sun 4.5:1 Pilot Ratio Load-Reactive Load Control Valve?▾
What is the difference between a load control valve and a counterbalance valve on the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve?▾
Do you stock the Sun Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations