Key features

  • Valve function: Atmospherically Vented Counterbalance Valve
  • Capacity: 7.5 gpm to 120 gpm (30 L/min to 480 L/min)
  • Max operating pressure: Max setting 6000 psi (420 bar), 4000 psi (280 bar)
  • Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
Valve function
Atmospherically Vented Counterbalance Valve
Series (frame sizes)
0 to 4
Cavity
T-163A, T-11A, T-2A, T-17A, T-19A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A 3-port counterbalance valve with its spring chamber open to atmosphere, so it fits the standard 3-port cavity yet ignores back-pressure in the return line. Free flow into the actuator passes the check (port 2 to port 1); the pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 lowers the setting by the pilot ratio.

Sizes and cavities

Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:

  • CAZA — series 0, T-163A cavity, 7.5 gpm (30 L/min), 0-series
  • CACA — series 1, T-11A cavity, 15 gpm (60 L/min)
  • CAEA — series 2, T-2A cavity, 30 gpm (120 L/min)
  • CAGA — series 3, T-17A cavity, 60 gpm (240 L/min)
  • CAIA — series 4, T-19A cavity, 120 gpm (480 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Pilot ratio: 3:1
  • Maximum setting: 6000 psi (420 bar), 4000 psi (280 bar)
  • Maximum recommended load pressure at maximum setting: 4615 psi (320 bar), 3075 psi (215 bar)
  • Maximum leakage: 5 drops/min. (0,3 cc/min)
  • Reseat: >85% of setting
  • Check cracking pressure: 25 psi (1,7 bar), 40 psi (2,8 bar), 20 psi (1,5 bar)

Configuration options

The letters after the base model code choose these options (shown for CACA; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
  • Setting range: H — 1000 - 4000 psi (70 - 280 bar), 3000 psi (210 bar) Standard Setting, I — 400 - 1500 psi (28 - 105 bar), 1000 psi (70 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.

Selection notes

  • Back-pressure at port 2 does not change the setting.
  • Roughly one drop of oil seeps past the pilot into the open spring chamber per 4,000 cycles, so mount it where that small weep is acceptable.
  • Set it at least 1.3 times the highest load-induced pressure.

Where it is used

Load-holding circuits with back-pressure at the valve where only a 3-port cavity is available — regeneration and proportional-valve circuits on mobile machines.

Installation and seal kits

Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, Viton: 990163006; series 1: Buna: 990211007, Viton: 990211006; series 2: Buna: 990302007, Viton: 990302006; series 3: Buna: 990117007, Polyurethane: 990117002, Viton: 990117006; series 4: Buna: 990119007, Polyurethane: 990119002, Viton: 990119006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CACALHN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 0: Buna: 990163007, Viton: 990163006; series 1: Buna: 990211007, Viton: 990211006; series 2: Buna: 990302007, Viton: 990302006; series 3: Buna: 990117007, Polyurethane: 990117002, Viton: 990117006; series 4: Buna: 990119007, Polyurethane: 990119002, Viton: 990119006
Weight.20 lb (0,10 kg) to 3.00 lb (1,35 kg)

Identification

ParameterValue
Valve functionAtmospherically Vented Counterbalance Valve
Series (frame sizes)0 to 4
CavityT-163A, T-11A, T-2A, T-17A, T-19A

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Performance

ParameterValue
Capacity7.5 gpm to 120 gpm (30 L/min to 480 L/min)
Max operating pressureMax setting 6000 psi (420 bar), 4000 psi (280 bar)
Pilot ratio3:1
Setting rangeH — 1000 - 4000 psi (70 - 280 bar), 3000 psi (210 bar) Standard Setting, I — 400 - 1500 psi (28 - 105 bar), 1000 psi (70 bar) Standard Setting
Max leakage5 drops/min. (0,3 cc/min)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations