Sun Hydraulics Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve — MWEGX, MWGGX, Series 2 to 3

Sun Hydraulics load-reactive load control valve, 4.5:1 pilot ratio: MWEGX, MWGGX, series 2 to 3, 30 gpm to 60 gpm (120 L/min to 240 L/min), T-22A, T-23A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Load-Reactive Load Control Valve
- Capacity: 30 gpm to 60 gpm (120 L/min to 240 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-22A, T-23A
- Valve function
- Load-Reactive Load Control Valve
- Series (frame sizes)
- 2 to 3
- Cavity
- T-22A, T-23A
Product description
A 3-port load control valve that works like a counterbalance valve: an integral check gives free flow into the actuator (port 2 to port 1) and a pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 lowers its setting by the pilot ratio. It seats as a poppet for tight holding and meters as a spool for smooth lowering.
Sizes and cavities
Sun Hydraulics builds this valve in 2 sizes. The series sets the cavity it screws into and its flow capacity:
- MWEGX — series 2, T-22A cavity, 30 gpm (120 L/min)
- MWGGX — series 3, T-23A cavity, 60 gpm (240 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 4.5:1
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 5 drops/min. (0,3 cc/min)
- Reseat: ≥77% of setting
- Check cracking pressure: 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for MWGGX; a size may add or drop a choice):
- Setting range: K — 3000 psi (210 bar), L — 4000 psi (280 bar), M — 5000 psi (350 bar)
- Seal material: N — Buna-N, V — Viton
Selection notes
- Set it at least 1.3 times the highest load-induced pressure, or 1.5 times where the setting is below 2,000 psi (140 bar).
- Back-pressure at port 2 adds to the effective setting, multiplied by one plus the pilot ratio — the vented versions avoid this.
- Turning the adjusting screw clockwise lowers the setting.
Where it is used
Load holding on large cylinders and motors in mobile and industrial machines, where higher flow is needed.
Installation and seal kits
Valve hex 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm). Replacement seal kits — series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example MWGGXKN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 30 gpm to 60 gpm (120 L/min to 240 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Pilot ratio | 4.5:1 |
| Setting range | K — 3000 psi (210 bar), L — 4000 psi (280 bar), M — 5000 psi (350 bar) |
| Max leakage | 5 drops/min. (0,3 cc/min) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Load-Reactive Load Control Valve |
| Series (frame sizes) | 2 to 3 |
| Cavity | T-22A, T-23A |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm) |
| Seal kits | series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006 |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton |
Shipping & lead time
Sizes & part numbers
2 sizes- Sun Hydraulics part no.MWEGX
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.MWGGX
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEGX, MWGGX) and what does it do?▾
How do I read the Sun model code for the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEGX, MWGGX)?▾
What sizes and flow capacities does the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve come in?▾
What pressure and setting range does the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve have?▾
Which seal and material options does the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve come with?▾
How is the setting of the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve chosen?▾
Which seal kit fits the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve (MWEGX, MWGGX)?▾
Which cavity and installation torque does the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve need?▾
Where is the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve used?▾
How does the Sun MWEGX valve differ from the Sun Fixed-Setting 4.5:1 Pilot Ratio Load-Reactive Load Control Valve?▾
What is the difference between a load control valve and a counterbalance valve on the Sun MWEGX valve?▾
Is the Sun Fixed-Setting Vented 4.5:1 Pilot Ratio Load-Reactive Load Control Valve in stock in Dubai, and can you ship it worldwide?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations