Sun Hydraulics Normally Closed, Balanced Poppet, Logic Element, Pilot-to-Open — DKDC to DKJS, Series 1 to 4

Sun Hydraulics Normally Closed, Balanced Poppet, Logic Element, Pilot-to-Open: DKDC to DKJS, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-21A, T-2A, T-22A, T-17A, T-23A and more cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Normally Closed Balanced Poppet Logic Element
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-21A, T-2A, T-22A, T-17A, T-23A, T-19A, T-24A
- Valve function
- Normally Closed Balanced Poppet Logic Element
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-21A, T-2A, T-22A, T-17A, T-23A, T-19A, T-24A
Product description
A normally closed 2-way logic element with a balanced poppet: pressure at ports 1 and 2 does not push it open, so it switches predictably on its control signal alone, with 5,000 psi (350 bar) at both work ports.
This version
- Normally closed.
Sizes and cavities
Sun Hydraulics builds this valve in 8 versions:
- DKDC — series 1, T-11A cavity, 15 gpm (60 L/min)
- DKDS — series 1, T-21A cavity, 15 gpm (60 L/min)
- DKFC — series 2, T-2A cavity, 30 gpm (120 L/min)
- DKFS — series 2, T-22A cavity, 30 gpm (120 L/min)
- DKHC — series 3, T-17A cavity, 60 gpm (240 L/min)
- DKHS — series 3, T-23A cavity, 60 gpm (240 L/min)
- DKJC — series 4, T-19A cavity, 120 gpm (480 L/min)
- DKJS — series 4, T-24A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Minimum pilot pressure to shift: 400 psi (28 bar), 300 psi (20 bar)
- Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar), 5 drops/min.@1000 psi (0,3 cc/min.@70 bar)
Configuration options
The letters after the base model code choose these options (shown for DKDC; a size may add or drop a choice):
- Control: E — External 4-SAE Drain Port, X — Standard Pilot, Atmospheric Vent
- Setting range: H — 400 psi (28 bar)
- Seal material: N — Buna-N, V — Viton, E — EPDM
- Material / coating: /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /LH, the control must be X; If the seal is E, the control must be E.
Selection notes
- Needs a minimum pilot pressure (about 400 psi, 30 bar, on series 1) with the external drain open.
- Same cavity as an unbalanced logic element of the same frame size, so it can replace one.
- X control vents to atmosphere (a fix for existing circuits that may weep over time); E control uses a static external drain, the better choice for new designs.
Where it is used
High-flow on/off switching and isolation in presses, test rigs and mobile valve blocks.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990311007, Viton: 990311006, Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006, Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006, Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006, Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DKDCEHN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Normally Closed Balanced Poppet Logic Element |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-21A, T-2A, T-22A, T-17A, T-23A, T-19A, T-24A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | H — 400 psi (28 bar) |
| Max leakage | 10 drops/min.@5000 psi (0,7 cc/min.@350 bar), 5 drops/min.@1000 psi (0,3 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | E — External 4-SAE Drain Port, X — Standard Pilot, Atmospheric Vent |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
| Material / coating | /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990311007, Viton: 990311006, Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006, Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006, Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 99001 |
| Weight | .35 lb (0,15 kg) |
Shipping & lead time
Sizes & part numbers
8 sizes- Sun Hydraulics part no.DKDC
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKDS
- Series
- 1
- Cavity
- T-21A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKFC
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKFS
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKHC
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKHS
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKJC
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DKJS
- Series
- 4
- Cavity
- T-24A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun DKDC to DKJS normally closed pilot-to-open logic element used for?▾
Which model codes does the Sun DKDC to DKJS normally closed pilot-to-open logic element cover?▾
What flow and cavity does the Sun DKDC to DKJS normally closed pilot-to-open logic element have?▾
What pressure is the Sun DKDC to DKJS normally closed pilot-to-open logic element rated for?▾
Which options and seals can I choose on the Sun DKDC to DKJS normally closed pilot-to-open logic element?▾
How should I read the selection notes for the Sun DKDC to DKJS normally closed pilot-to-open logic element?▾
What hex size and installation torque does the Sun DKDC to DKJS normally closed pilot-to-open logic element need?▾
Which seal kits fit the Sun DKDC to DKJS normally closed pilot-to-open logic element?▾
Where is the Sun DKDC to DKJS normally closed pilot-to-open logic element typically used?▾
How does the Sun DKDC to DKJS normally closed pilot-to-open logic element compare with the Sun DKDP to DKJP version?▾
Does Indus supply the Sun DKDC to DKJS normally closed pilot-to-open logic element direct from the maker?▾
Is the Sun DKDC to DKJS normally closed pilot-to-open logic element in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations