Sun Hydraulics 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced — CACL, CAEL, CAGL, CAIL, Series 1 to 4

Sun Hydraulics atmospherically vented counterbalance valve, 2:1 pilot ratio: CACL, CAEL, CAGL, CAIL, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Atmospherically Vented Counterbalance Valve
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: Max setting 6000 psi (420 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Atmospherically Vented Counterbalance Valve
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
A 3-port counterbalance valve with its spring chamber open to atmosphere, so it fits the standard 3-port cavity yet ignores back-pressure in the return line. Free flow into the actuator passes the check (port 2 to port 1); the pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 lowers the setting by the pilot ratio.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- CACL — series 1, T-11A cavity, 15 gpm (60 L/min)
- CAEL — series 2, T-2A cavity, 30 gpm (120 L/min)
- CAGL — series 3, T-17A cavity, 60 gpm (240 L/min)
- CAIL — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 2:1
- Maximum setting: 6000 psi (420 bar)
- Maximum recommended load pressure at maximum setting: 4615 psi (320 bar)
- Maximum leakage: 5 drops/min. (0,3 cc/min)
- Reseat: >85% of setting
- Check cracking pressure: 40 psi (2,8 bar), 25 psi (1,7 bar), 20 psi (1,5 bar)
Configuration options
The letters after the base model code choose these options (shown for CACL; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
- Setting range: F — 1000 - 2500 psi (70 - 175 bar), 2000 psi (140 bar) Standard Setting, G — 2000 - 6000 psi (140 - 420 bar), 4000 psi (280 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /LH, the control must be L.
Selection notes
- Back-pressure at port 2 does not change the setting.
- Roughly one drop of oil seeps past the pilot into the open spring chamber per 4,000 cycles, so mount it where that small weep is acceptable.
- Set it at least 1.3 times the highest load-induced pressure.
Where it is used
Load-holding circuits with back-pressure at the valve where only a 3-port cavity is available — regeneration and proportional-valve circuits on mobile machines.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990211007, Viton: 990211006; series 2: Buna: 990302007, Viton: 990302006; series 3: Buna: 990117007, Polyurethane: 990117002, Viton: 990117006; series 4: Buna: 990119007, Polyurethane: 990119002, Viton: 990119006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CACLLFN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990211007, Viton: 990211006; series 2: Buna: 990302007, Viton: 990302006; series 3: Buna: 990117007, Polyurethane: 990117002, Viton: 990117006; series 4: Buna: 990119007, Polyurethane: 990119002, Viton: 990119006 |
| Weight | .40 lb (0,20 kg) to 3.00 lb (1,35 kg) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Atmospherically Vented Counterbalance Valve |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /LH — Mild Steel, Zinc-Nickel |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | Max setting 6000 psi (420 bar) |
| Pilot ratio | 2:1 |
| Setting range | F — 1000 - 2500 psi (70 - 175 bar), 2000 psi (140 bar) Standard Setting, G — 2000 - 6000 psi (140 - 420 bar), 4000 psi (280 bar) Standard Setting |
| Max leakage | 5 drops/min. (0,3 cc/min) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.CACL
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Sun Hydraulics part no.CAEL
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Sun Hydraulics part no.CAGL
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Sun Hydraulics part no.CAIL
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced (CACL, CAEL, CAGL and others) and what does it do?▾
How do I read the Sun model code for the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced (CACL, CAEL, CAGL and others)?▾
What sizes and flow capacities does the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced come in?▾
What pressure and setting range does the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced have?▾
Which seal and material options does the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced come with?▾
How is the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced adjusted, and which control options are offered?▾
Which seal kit fits the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced (CACL, CAEL, CAGL and others)?▾
Which cavity and installation torque does the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced need?▾
Where is the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced used?▾
How does the Sun CACL valve differ from the Sun 1:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced?▾
Which pilot ratio should I choose on the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced?▾
Do you stock the Sun 2:1 Pilot Ratio Vented Counterbalance Valve, Atmospherically Referenced in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations