Sun Hydraulics 2-Way, Pilot-Operated, Directional Valve with Drain to Port 4, Normally Open — DPBM, DPCM, Series 1 to 2

Sun Hydraulics 2-Way, Pilot-Operated, Directional Valve with Drain to Port 4, Normally Open: DPBM, DPCM, series 1 to 2, 7 gpm to 15 gpm (28 L/min to 60 L/min), T-21A, T-22A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-Operated Pressure-Operated Directional Valve
- Capacity: 7 gpm to 15 gpm (28 L/min to 60 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A
- Valve function
- Pilot-Operated Pressure-Operated Directional Valve
- Series (frame sizes)
- 1 to 2
- Cavity
- T-21A, T-22A
Product description
A pilot-operated directional cartridge that shifts once the pressure difference between port 1 and the drain passes its setting. A small pilot stage sets the spool, so the switching point holds closely as flow changes. It can switch a moderate flow itself or pilot a larger directional or logic cartridge.
This version
- Normally open.
- The spring chamber drains to a separate port 4, so pressure at port 3 does not shift the setting and port 3 can work as a load port.
Sizes and cavities
Sun Hydraulics builds this valve in 2 versions:
- DPBM — series 1, T-21A cavity, 7 gpm (28 L/min)
- DPCM — series 2, T-22A cavity, 15 gpm (60 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 1 in³/min.@1000 psi (15 cc/min.@70 bar)
- Control pilot flow: 7 - 10 in³/min. (0,11 - 0,16 L/min), 10 - 15 in³/min. (0,16 - 0,25 L/min)
Configuration options
The letters after the base model code choose these options (shown for DPBM; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, J — 25 - 1500 psi (1,7 - 105 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.
Selection notes
- Keep port 3 at or below 3,000 psi (210 bar) on the internally drained versions; the limit is set by fatigue strength.
- Pilot flow is small, about 7 to 10 in³/min on series 1.
- For series 1 valves with a panel-mount handknob, cut a 0.75 in (19 mm) hole in the panel.
Where it is used
Pressure-sequenced switching — unloading, high-low pump circuits, interlocks, piloting logic elements.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DPBMLAN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-Operated Pressure-Operated Directional Valve |
| Series (frame sizes) | 1 to 2 |
| Cavity | T-21A, T-22A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 7 gpm to 15 gpm (28 L/min to 60 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, J — 25 - 1500 psi (1,7 - 105 bar), 1000 psi (70 bar) Standard Setting |
| Max leakage | 1 in³/min.@1000 psi (15 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm) |
| Seal kits | series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006 |
| Weight | .60 lb (0,30 kg) |
Shipping & lead time
Sizes & part numbers
2 sizes- Sun Hydraulics part no.DPBM
- Series
- 1
- Cavity
- T-21A
- Capacity
- 7 gpm / 28 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DPCM
- Series
- 2
- Cavity
- T-22A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve used for?▾
Which sizes and versions does the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve come in?▾
How do I read the Sun Hydraulics model code DPBMLAN for the DPBM, DPCM pilot-operated pressure-operated directional valve?▾
What is the maximum operating pressure of the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve?▾
What flow capacity does the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve have by series?▾
Which seal materials and body finishes does the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve come with?▾
Which cavity does the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve fit?▾
Which seal kit fits the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve?▾
How is the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve installed?▾
Where is the Sun Hydraulics DPBM, DPCM pilot-operated pressure-operated directional valve used?▾
Sun Hydraulics DPBM, DPCM or DPBN, DPCN: what is the difference?▾
Do you stock the Sun Hydraulics DPBM, DPCM in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations