Stainless Steel Heat Exchanger Tubes

Seamless and welded austenitic stainless tubes in TP304, 304L, 316, 316L, 321 and 347, with duplex to ASTM A789, for heat exchangers, condensers and feedwater heaters. Made to ASTM A213 / ASME SA-213, ASTM A269, ASTM A249 / ASME SA-249. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: Stainless Steel Heat Exchanger Tubes
- Construction: Seamless, cold drawn or hot finished
- Standards: ASTM A213 / ASME SA-213, ASTM A269, ASTM A249 / ASME SA-249, ASTM A312, ASTM A789, ASTM A790, ASTM A1016, BS 3059
- Base tube material: TP304/304L; TP316/316L; TP321; TP347; S31803; S32205; S32750
- Outside diameter: 15.88–31.75 mm
- Wall thickness: 0.889–2.769 mm
- Product type
- Stainless Steel Heat Exchanger Tubes
- Construction
- Seamless, cold drawn or hot finished
- Base tube material
- TP304/304L; TP316/316L; TP321; TP347; S31803; S32205; S32750
Product description
Seamless and welded austenitic stainless tubes in TP304, 304L, 316, 316L, 321 and 347, with duplex to ASTM A789, for heat exchangers, condensers and feedwater heaters. Ordered by OD and BWG wall, as minimum or average wall.
Specification
- ASTM A213 size scope (as usually furnished): ID 3.2 mm (1/8 in) to OD 127 mm (5 in); min wall 0.4–12.7 mm (0.015–0.500 in); average wall if ordered
- ASTM A269 size scope: ID 6.4 mm (1/4 in) and larger, nominal wall 0.51 mm (0.020 in) and heavier; mechanical tests not required below 3.2 mm ID or 0.38 mm wall
- ASTM A249 (welded) size scope: ID 3.2 mm to OD 304.8 mm (12 in); wall 0.4–8.1 mm (0.015–0.320 in)
- ASTM A312 product: Seamless, straight-seam welded and heavily cold-worked welded austenitic pipe; H grades for creep service; wall tolerance −12.5 % (table by t/D)
- ASTM A789 (duplex tube) basis: Average wall (or minimum wall if ordered); aimed at stress-corrosion-cracking resistance
- Solution anneal, A213/A269/A249 300-series: 1040 °C (1900 °F) minimum, water quench or other rapid cool; H and stabilised grades have own minimums
- Hardness max, TP304/304L/316/316L/321/347: 192 HBW / 200 HV / 90 HRB
- OD tolerance, cold-finished seamless and welded tube (A1016): Under 25.4 mm: +0.10/−0.11 mm; 25.4–38.1 mm: ±0.15 mm; 38.1–50.8 mm: ±0.20 mm (includes out-of-round)
- Wall tolerance, min-wall tube (A1016): Seamless cold-finished ≤38.1 mm OD: +20/−0 %; over 38.1 mm: +22/−0 %; welded: +18/−0 %
- Wall tolerance, A269 (nominal wall): ±15 % under 12.7 mm OD; ±10 % from 12.7 mm upward; OD ±0.13 mm up to 38.1 mm
- Hydrostatic test pressure (A1016 general requirement): P = 220.6·t/D MPa (32 000·t/D psi); need not exceed 7 MPa (1000 psi); hold ≥5 s; may replace or be replaced by electric NDE
- Mill OD range for stainless HX tube: 12–88.9 mm OD (group); individual mills 12.7–25.4, 15–58, 19–88.9 mm
- BWG to mm: 20 = 0.89; 18 = 1.24; 16 = 1.65; 14 = 2.11; 12 = 2.77; 10 = 3.40 mm
- Most-requested stainless HX sizes: 19.05 × 1.65, 19.05 × 2.11, 25.4 × 1.65, 25.4 × 2.11 mm
Standards
ASTM A213 / ASME SA-213, ASTM A269, ASTM A249 / ASME SA-249, ASTM A312, ASTM A789, ASTM A790, ASTM A1016, BS 3059. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: TP304/304L; TP316/316L; TP321; TP347; S31803; S32205; S32750
Testing and documents
- A249 adds reverse-bend/flange tests on welded tube; optional weld-decay test S7
- Flattening, flaring, hardness, tension per A213/A1016
- Hydrostatic per A1016 (P = 220.6 t/D MPa, max 7 MPa needed, 5 s hold) or electric NDE (eddy current/ultrasonic)
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Crude/vacuum overhead condensers — duplex/super duplex
- Naphthenic-acid service — 317L or 316L with ≥2.5 % Mo
- Offshore platform exchangers in chloride service — duplex/super duplex
- Refinery hydrotreater REAC/FEAC coolers and amine coolers — duplex 2205/2507 and Alloy 825
- Sour-water strippers and interstage coolers with chloride cooling water — duplex
Sizes
23 sizes, each under its own Indus part number in the size table. The table lists typical sizes for the range; other sizes are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Stainless Steel Heat Exchanger Tubes |
| Construction | Seamless, cold drawn or hot finished |
Compliance
| Parameter | Value |
|---|---|
| Standards | ASTM A213 / ASME SA-213, ASTM A269, ASTM A249 / ASME SA-249, ASTM A312, ASTM A789, ASTM A790, ASTM A1016, BS 3059 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | TP304/304L; TP316/316L; TP321; TP347; S31803; S32205; S32750 |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 15.88–31.75 mm |
| Wall thickness | 0.889–2.769 mm |
| Length | Random or fixed lengths; cut to length on request |
| Size table | Typical sizes — other sizes on request |
Quality
| Parameter | Value |
|---|---|
| Testing | A249 adds reverse-bend/flange tests on welded tube; optional weld-decay test S7; Flattening, flaring, hardness, tension per A213/A1016; Hydrostatic per A1016 (P = 220.6 t/D MPa, max 7 MPa needed, 5 s hold) or electric NDE (eddy current/ultrasonic) |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Crude/vacuum overhead condensers — duplex/super duplex; Naphthenic-acid service — 317L or 316L with ≥2.5 % Mo; Offshore platform exchangers in chloride service — duplex/super duplex |
Shipping & lead time
Sizes & part numbers
23 sizes- Indus part no.IH-TF-SS-AUS-0159-089
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 20
- Wall (mm)
- 0.889
- Wall (in)
- 0.035
- Indus part no.IH-TF-SS-AUS-0159-125
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 18
- Wall (mm)
- 1.245
- Wall (in)
- 0.049
- Indus part no.IH-TF-SS-AUS-0159-165
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 16
- Wall (mm)
- 1.651
- Wall (in)
- 0.065
- Indus part no.IH-TF-SS-AUS-0159-211
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 14
- Wall (mm)
- 2.108
- Wall (in)
- 0.083
- Indus part no.IH-TF-SS-AUS-0159-277
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 12
- Wall (mm)
- 2.769
- Wall (in)
- 0.109
- Indus part no.IH-TF-SS-AUS-0190-089
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 20
- Wall (mm)
- 0.889
- Wall (in)
- 0.035
- Indus part no.IH-TF-SS-AUS-0190-125
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 18
- Wall (mm)
- 1.245
- Wall (in)
- 0.049
- Indus part no.IH-TF-SS-AUS-0190-165
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 16
- Wall (mm)
- 1.651
- Wall (in)
- 0.065
Show all 23 sizesShow fewer sizes
- Indus part no.IH-TF-SS-AUS-0190-211
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 14
- Wall (mm)
- 2.108
- Wall (in)
- 0.083
- Indus part no.IH-TF-SS-AUS-0190-277
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 12
- Wall (mm)
- 2.769
- Wall (in)
- 0.109
- Indus part no.IH-TF-SS-AUS-0222-125
- O.D. (mm)
- 22.23
- O.D. (in)
- 7/8
- BWG
- 18
- Wall (mm)
- 1.245
- Wall (in)
- 0.049
- Indus part no.IH-TF-SS-AUS-0222-165
- O.D. (mm)
- 22.23
- O.D. (in)
- 7/8
- BWG
- 16
- Wall (mm)
- 1.651
- Wall (in)
- 0.065
- Indus part no.IH-TF-SS-AUS-0222-211
- O.D. (mm)
- 22.23
- O.D. (in)
- 7/8
- BWG
- 14
- Wall (mm)
- 2.108
- Wall (in)
- 0.083
- Indus part no.IH-TF-SS-AUS-0222-277
- O.D. (mm)
- 22.23
- O.D. (in)
- 7/8
- BWG
- 12
- Wall (mm)
- 2.769
- Wall (in)
- 0.109
- Indus part no.IH-TF-SS-AUS-0254-089
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 20
- Wall (mm)
- 0.889
- Wall (in)
- 0.035
- Indus part no.IH-TF-SS-AUS-0254-125
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 18
- Wall (mm)
- 1.245
- Wall (in)
- 0.049
- Indus part no.IH-TF-SS-AUS-0254-165
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 16
- Wall (mm)
- 1.651
- Wall (in)
- 0.065
- Indus part no.IH-TF-SS-AUS-0254-211
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 14
- Wall (mm)
- 2.108
- Wall (in)
- 0.083
- Indus part no.IH-TF-SS-AUS-0254-277
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 12
- Wall (mm)
- 2.769
- Wall (in)
- 0.109
- Indus part no.IH-TF-SS-AUS-0318-125
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 18
- Wall (mm)
- 1.245
- Wall (in)
- 0.049
- Indus part no.IH-TF-SS-AUS-0318-165
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 16
- Wall (mm)
- 1.651
- Wall (in)
- 0.065
- Indus part no.IH-TF-SS-AUS-0318-211
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 14
- Wall (mm)
- 2.108
- Wall (in)
- 0.083
- Indus part no.IH-TF-SS-AUS-0318-277
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 12
- Wall (mm)
- 2.769
- Wall (in)
- 0.109
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. BWG — Birmingham Wire Gauge of the wall, the usual way heat-exchanger tube wall is ordered. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Wall (in) — The same wall thickness in inches.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are stainless steel heat exchanger tubes used for?▾
How do I read the Indus part numbers such as IH-TF-SS-AUS-0159-089?▾
Which outside diameters and BWG walls do stainless steel heat exchanger tubes come in?▾
How do I order stainless heat exchanger tube: minimum wall or average wall?▾
What tolerances and test pressure apply to the Stainless Steel Heat Exchanger Tubes?▾
Which stainless grades are available for these heat exchanger tubes?▾
Which standards and certificates apply to the Stainless Steel Heat Exchanger Tubes?▾
What do I use with the Stainless Steel Heat Exchanger Tubes in an exchanger?▾
How are the Stainless Steel Heat Exchanger Tubes tested and treated after forming?▾
How do austenitic tubes compare with ferritic and martensitic stainless tubes?▾
Can you export the Stainless Steel Heat Exchanger Tubes from Dubai?▾
Do you keep the Stainless Steel Heat Exchanger Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Heat-transfer tubes
Stainless heat exchanger tube: A213, A249, A268 and A789 grades
Seamless or welded, austenitic, ferritic or duplex: how the four main ASTM stainless tube standards divide up, what each grade is chosen for in refinery, gas-plant and power service, and the tests that come with them.
3 min read
Heat-transfer tubes
Reading a mill test certificate to EN 10204 3.1
Every length of pressure tube should be traceable to a certificate. What EN 10204 types 2.1, 2.2, 3.1 and 3.2 mean, what a 3.1 certificate for tube should contain, and the checks to make before the tube goes into a bundle.
3 min read