Parker P32 Compact Global Modular Particulate Filters

Parker P32 Compact Global Modular Particulate Filters in polycarbonate bowl with nylon guard nitrile seals aluminum housing abs body cap acetal element retainer acetal baffle sintered polyethylene filter element polypropylene deflector: 12 part numbers.
Product description
Parker P32 Compact Global Modular Particulate Filters in polycarbonate bowl with nylon guard nitrile seals aluminum housing abs body cap acetal element retainer acetal baffle sintered polyethylene filter element polypropylene deflector: 12 part numbers.
Specification
- Type: Particulate Filter
- Material: Polycarbonate Bowl With Nylon Guard Nitrile Seals Aluminum Housing ABS Body Cap Acetal Element Retainer Acetal Baffle Sintered Polyethylene Filter Element Polypropylene Deflector
- Connection Type: NPT
- Seal Material: Nitrile
- Part numbers: 12
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Sizing air preparation
Size filters, regulators and lubricators on port size and the air flow the downstream tools and cylinders need, not on line size alone; an undersized unit drops pressure at full flow. Quote the maker part number and we will confirm bowl, drain and gauge options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Air Preparation Product Type | Particulate Filter |
| Air Preparation Series | Global Modular |
| Ambient Air Temp. For Operation | -13°F to +125°F |
| Bowl Type | Poly With Bowl Guard |
| Connection Type | NPT |
| Design | 5 µm Particulate Filtration Grade Automatic Drain |
| Distance To Remove Bowl | 1 3/5" |
| Division | Pneumatic |
| Filter Drain Type | Auto Float |
| Functions | Pneumatic Compact Air Filter (F) |
| Gender | Female |
| Group | Automation |
| Main Function | Filter (Air) |
| Material | Polycarbonate Bowl With Nylon Guard Nitrile Seals Aluminum Housing ABS Body Cap Acetal Element Retainer Acetal Baffle Sintered Polyethylene Filter Element Polypropylene Deflector |
| Max. Temp. | 125°F |
| Series | P32 Compact Series |
| Sub Range Name | P32FB Series |
Shipping & lead time
Sizes & part numbers
12 sizes- Parker Hannifin part no.P32FB92EGAN
- Description
- Airline Particulate Filter, Modular, Auto Float, 15-150 Psig
- Parker Hannifin part no.P32FB92EGMN
- Description
- Airline Particulate Filter, Modular, Manual, 0-150 Psig
- Parker Hannifin part no.P32FB92ESAN
- Description
- Airline Particulate Filter, Modular, Auto Float, 15-250 Psig
- Parker Hannifin part no.P32FB92ESMN
- Description
- Airline Particulate Filter, Modular, Manual, 0-250 Psig
- Parker Hannifin part no.P32FB93ESMN
- Description
- Airline Particulate Filter, Modular, Manual, 0-250 Psig
- Parker Hannifin part no.P32FB93EGAN
- Description
- Airline Particulate Filter
- Parker Hannifin part no.P32FB93EGMN
- Description
- Airline Particulate Filter, Manual, 0-150 Psig
- Parker Hannifin part no.P32FB93ESAN
- Description
- Airline Particulate Filter, Auto Float, 15-250 Psig
Show all 12 sizesShow fewer sizes
- Parker Hannifin part no.P32FB94EGMN
- Description
- Airline Particulate Filter, Manual, 0-150 Psig
- Parker Hannifin part no.P32FB94EGAN
- Description
- Airline Particulate Filter, Auto Float, 15-150 Psig
- Parker Hannifin part no.P32FB94ESMN
- Description
- Airline Particulate Filter, Manual, 0-250 Psig
- Parker Hannifin part no.P32FB94ESAN
- Description
- Airline Particulate Filter, Auto Float, 15-250 Psig
Description — What this part number is, as the manufacturer lists it. Ask us for the dimension drawing if you need it stamped.
What does the Parker P32 Compact Global Modular Particulate Filters do in a compressed-air line?▾
Which part numbers are in the Parker P32 Compact Global Modular Particulate Filters range and how do they differ?▾
What port sizes and flow ratings does the Parker P32 Compact Global Modular Particulate Filters come in?▾
How do I choose the right Parker P32 Compact Global Modular Particulate Filters part number for my air line?▾
What is the maximum working pressure of the Parker P32 Compact Global Modular Particulate Filters?▾
What filter grade, bowl and body materials does the Parker P32 Compact Global Modular Particulate Filters use?▾
Does the Parker P32 Compact Global Modular Particulate Filters give a stated ISO 8573-1 air quality class?▾
What should I fit before and after the Parker P32 Compact Global Modular Particulate Filters in an air line?▾
How should I drain and service the Parker P32 Compact Global Modular Particulate Filters?▾
What is the difference between the Parker P32 Compact Global Modular Particulate Filters and the Parker P32 Compact Global Modular Coalescing Filters?▾
What are the origin and HS code details for the Parker P32 Compact Global Modular Particulate Filters?▾
Is the Parker P32 Compact Global Modular Particulate Filters available from stock at Indus Hydraulics?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
FRL units explained: filter, regulator and lubricator — order, grades, drains, bowls and sizing
An FRL is the last thing compressed air passes through before it reaches a valve or cylinder. What each element does and why the order is filter, regulator, lubricator; particulate vs coalescing grades in microns; manual, semi-automatic and automatic drains; relieving regulators; when to lubricate; polycarbonate vs metal bowls; and sizing by flow, not port size.
17 min read
Pneumatics & compressed air
Compressed air quality and ISO 8573-1: purity classes, pressure dew point and where to fix the water
ISO 8573-1 writes air quality as three numbers — particles, water, oil. What [2:4:2] or [7:4:3] actually means, which classes food, paint, tools and valves are commonly specified at, why hot, humid air drops so much water once it is compressed and cooled, and why drains, coalescing filters and dryers — not the FRL at the machine — are where water is removed.
14 min read
Pneumatics & compressed air
How to size a pneumatic cylinder: force, load ratio, pressure at the port and air consumption
Theoretical force is pressure times piston area, and the return stroke only gets the annulus. How much margin Parker recommends, why to size on the pressure at the cylinder rather than the compressor, how to work out air per cycle in free air, a worked example in bar/mm and psi/inch, and force tables for common bores at 6 bar and 80 psi.
22 min read