Ingersoll Rand High Efficiency Filters

Ingersoll Rand High Efficiency Filters: 3 part numbers.
Product description
Ingersoll Rand High Efficiency Filters: 3 part numbers.
Specification
- Type: High Efficiency Filter
- Pressure stated by the maker: 250 psi (17 bar)
- Temperature: 176°F
- Part numbers: 3
Sizes and part numbers
The Sizes & Part Numbers tab lists every Ingersoll Rand part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Sizing air preparation
Size filters, regulators and lubricators on port size and the air flow the downstream tools and cylinders need, not on line size alone; an undersized unit drops pressure at full flow. Quote the maker part number and we will confirm bowl, drain and gauge options before supply.
How to order
Quote the Ingersoll Rand part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Air Outlet Type | NPT |
| Body Material | Aluminum |
| Drain Included | Yes |
| Drain Type | Automatic |
| For Fluid Type | Oil, Water |
| For Substance Type | Oil Aerosols, Water |
| Gauge Included | No |
| Housing Material | Aluminum |
| Included | Internal Drain, Pressure Differential Gauge |
| Inlet Type | NPT |
| No. Of Air Inlets | 1 |
| No. Of Air Outlets | 1 |
| Series | F Series |
Shipping & lead time
Sizes & part numbers
3 sizes- Ingersoll Rand part no.FA75IH
- Description
- High Efficiency Filter 3/4 Inch NPT 45 cfm
- Max pressure (psi)
- 250
- Ingersoll Rand part no.FA110IH
- Description
- High Efficiency Filter 3/4 Inch Npt 65 Cfm
- Max pressure (psi)
- 250
- Ingersoll Rand part no.FA400IH
- Description
- High Efficiency Filter 250 psi 235cfm
- Max pressure (psi)
- 250
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What are the Ingersoll Rand High Efficiency Filters used for?▾
Which part numbers are in the Ingersoll Rand High Efficiency Filters range and how do they differ?▾
What port sizes and flow ratings does the Ingersoll Rand High Efficiency Filters come in?▾
How do I choose the right Ingersoll Rand High Efficiency Filters part number for my air line?▾
What is the maximum working pressure of the Ingersoll Rand High Efficiency Filters?▾
What element grade and materials does the Ingersoll Rand High Efficiency Filters use?▾
Does the Ingersoll Rand High Efficiency Filters give a stated ISO 8573-1 air quality class?▾
What should I fit before and after the Ingersoll Rand High Efficiency Filters in an air line?▾
How should I drain and service the Ingersoll Rand High Efficiency Filters?▾
What is the difference between the Ingersoll Rand High Efficiency Filters and the Ingersoll Rand Main Line Compressed Air Filters?▾
Where is the Ingersoll Rand High Efficiency Filters made and how is it shipped from Dubai?▾
Can I buy the Ingersoll Rand High Efficiency Filters ex-stock from Indus in the UAE?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
FRL units explained: filter, regulator and lubricator — order, grades, drains, bowls and sizing
An FRL is the last thing compressed air passes through before it reaches a valve or cylinder. What each element does and why the order is filter, regulator, lubricator; particulate vs coalescing grades in microns; manual, semi-automatic and automatic drains; relieving regulators; when to lubricate; polycarbonate vs metal bowls; and sizing by flow, not port size.
17 min read
Pneumatics & compressed air
Compressed air quality and ISO 8573-1: purity classes, pressure dew point and where to fix the water
ISO 8573-1 writes air quality as three numbers — particles, water, oil. What [2:4:2] or [7:4:3] actually means, which classes food, paint, tools and valves are commonly specified at, why hot, humid air drops so much water once it is compressed and cooled, and why drains, coalescing filters and dryers — not the FRL at the machine — are where water is removed.
14 min read
Pneumatics & compressed air
How to size a pneumatic cylinder: force, load ratio, pressure at the port and air consumption
Theoretical force is pressure times piston area, and the return stroke only gets the annulus. How much margin Parker recommends, why to size on the pressure at the cylinder rather than the compressor, how to work out air per cycle in free air, a worked example in bar/mm and psi/inch, and force tables for common bores at 6 bar and 80 psi.
22 min read