High-Frequency Welded Spiral Fin Tubes — Solid and Serrated

Steel fin strip welded helically to the base tube by high-frequency resistance welding, in a solid fin or a serrated (segmented) fin. Made to API 560, ASTM A106, ASTM A192. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: High-Frequency Welded Spiral Fin Tubes
- Standards: API 560, ASTM A106, ASTM A192, ASTM A210, ASTM A213, ASTM A335
- Base tube material: CS A106 B, A192, A210; Cr-Mo A213 T5/T9/T11/T22, A335 P5/P9/P11/P22; Stainless A312/A213 TP304H/321/347
- Fin material: Carbon steel; 11–13Cr (Type 405/410S); 18Cr-8Ni; 25Cr-20Ni
- Outside diameter: 50.8 mm
- Wall thickness: 1.98–16.0 (0.078–0.630 in)
- Maximum service temperature: Set by fin material; fired-heater fin-tip limits per API 560: carbon steel 454 °C, 2¼Cr / 5Cr 549 °C, 25Cr-20Ni 982 °C
- Product type
- High-Frequency Welded Spiral Fin Tubes
- Base tube material
- CS A106 B, A192, A210; Cr-Mo A213 T5/T9/T11/T22, A335 P5/P9/P11/P22; Stainless A312/A213 TP304H/321/347
- Fin material
- Carbon steel; 11–13Cr (Type 405/410S); 18Cr-8Ni; 25Cr-20Ni
Product description
Steel fin strip welded helically to the base tube by high-frequency resistance welding, in a solid fin or a serrated (segmented) fin. The weld makes the fin part of the tube, so these fins carry the high gas temperatures of HRSGs, economisers and fired-heater convection sections, where the fin material, not the bond, sets the limit.
Specification
- Maximum service temperature: Set by fin material; fired-heater fin-tip limits per API 560: carbon steel 454 °C, 2¼Cr / 5Cr 549 °C, 25Cr-20Ni 982 °C
- Base tube OD (mm): 25.4–219.1 (1–8 5/8 in)
- Base tube wall (mm): 1.98–16.0 (0.078–0.630 in)
- Fin material: Carbon steel, low-alloy (Cr-Mo, 11–13Cr), stainless
- Max length (m): 18.3 (60 ft)
- Fin height, solid (mm): 9.5–31.75 (3/8–1 1/4 in)
- Fin thickness, solid (mm): 0.89–3.05 (0.035–0.120 in)
- Fin density, solid: 1–6 FPI (39–236 fins/m)
- Fin height, serrated (mm): 12.7–31.75 (1/2–1 1/4 in)
- Fin thickness, serrated (mm): 0.89–1.65 (0.035–0.065 in)
- Fin density, serrated: 1–6 FPI (39–236 fins/m)
- Segment width (mm): 4.0 or 7.9 (5/32 or 5/16 in)
- Unserrated base (mm): ≈5–6.35
- HRSG economiser base OD: 50.8 mm (2 in) is the usual standard
Standards
API 560, ASTM A106, ASTM A192, ASTM A210, ASTM A213, ASTM A335. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: CS A106 B, A192, A210; Cr-Mo A213 T5/T9/T11/T22, A335 P5/P9/P11/P22; Stainless A312/A213 TP304H/321/347
- Fins: Carbon steel; 11–13Cr (Type 405/410S); 18Cr-8Ni; 25Cr-20Ni
Testing and documents
- Base tube hydrotest per its spec
- Weld-bond / fin pull and visual checks per maker; no public standard value found
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Fired-heater convection sections in refineries
- Gas-fired heater convection banks
- HRSG economisers and evaporators in GCC combined-cycle and IWPP plants
- HRSG superheaters, evaporators and economisers in combined-cycle power and water plants
Sizes
3 sizes, each under its own Indus part number in the size table. The table gives the range as limits; any size inside it is made to order.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the fin type, material, height, thickness and fins per inch, and the bare length at each end. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | High-Frequency Welded Spiral Fin Tubes |
Compliance
| Parameter | Value |
|---|---|
| Standards | API 560, ASTM A106, ASTM A192, ASTM A210, ASTM A213, ASTM A335 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | CS A106 B, A192, A210; Cr-Mo A213 T5/T9/T11/T22, A335 P5/P9/P11/P22; Stainless A312/A213 TP304H/321/347 |
| Fin material | Carbon steel; 11–13Cr (Type 405/410S); 18Cr-8Ni; 25Cr-20Ni |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 50.8 mm |
| Wall thickness | 1.98–16.0 (0.078–0.630 in) |
| Length | 18.3 m maximum single length |
| Size table | Size range — discrete sizes on request |
Performance
| Parameter | Value |
|---|---|
| Maximum service temperature | Set by fin material; fired-heater fin-tip limits per API 560: carbon steel 454 °C, 2¼Cr / 5Cr 549 °C, 25Cr-20Ni 982 °C |
Quality
| Parameter | Value |
|---|---|
| Testing | Base tube hydrotest per its spec; Weld-bond / fin pull and visual checks per maker; no public standard value found |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Fired-heater convection sections in refineries; Gas-fired heater convection banks; HRSG economisers and evaporators in GCC combined-cycle and IWPP plants |
Shipping & lead time
Sizes & part numbers
3 sizes- Indus part no.IH-TF-HF-HFW-R1
- O.D. (mm)
- 25.4–219.1
- O.D. (in)
- 1–8 5/8
- Wall (mm)
- 1.98–16.0
- Fin O.D. (mm)
- —
- Fin height (mm)
- 9.5–31.75
- Fin thickness (mm)
- 0.89–3.05
- Fins per inch
- 1–6
- Segment width (mm)
- —
- Max. length (m)
- 18.3
- Indus part no.IH-TF-HF-HFW-R2
- O.D. (mm)
- 25.4–219.1
- O.D. (in)
- 1–8 5/8
- Wall (mm)
- 1.98–16.0
- Fin O.D. (mm)
- —
- Fin height (mm)
- 12.7–31.75
- Fin thickness (mm)
- 0.89–1.65
- Fins per inch
- 1–6
- Segment width (mm)
- 4.0 or 7.9
- Max. length (m)
- 18.3
- Indus part no.IH-TF-HF-HFW-0508
- O.D. (mm)
- 50.8
- O.D. (in)
- 2
- Wall (mm)
- —
- Fin O.D. (mm)
- 88.9
- Fin height (mm)
- 19.05
- Fin thickness (mm)
- 1.27
- Fins per inch
- 5
- Segment width (mm)
- 4.37
- Max. length (m)
- —
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Fin O.D. (mm) — Outside diameter over the fins in millimetres. Fin height (mm) — Height of the fin above the tube surface in millimetres. Fin thickness (mm) — Fin strip or plate thickness in millimetres. Fins per inch — Fin density in fins per inch; a band means any density in it can be made. Segment width (mm) — Width of each segment on a serrated (segmented) fin, in millimetres. Max. length (m) — Longest single length usually made, in metres; longer on request.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are high-frequency welded spiral fin tubes used for?▾
What do the part numbers IH-TF-HF-HFW-R1, R2 and 0508 mean?▾
What base tube sizes do HF welded spiral fin tubes come in?▾
What fin heights, thicknesses and densities does a solid fin have?▾
What is the maximum temperature of HF welded spiral fin tubes?▾
Which fin and tube materials are available for HF welded spiral fin tubes?▾
Which standards apply to HF welded spiral fin tubes?▾
What tests and certificates come with HF welded fin tubes?▾
Solid or serrated fins for HF welded spiral fin tubes?▾
What if I need a larger bore than finned tube gives?▾
Where are HF welded spiral fin tubes used?▾
Can I buy HF welded spiral fin tubes from Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Heat-transfer tubes
HF-welded spiral fin tubes: solid or serrated?
High-frequency welded spiral fins are the workhorse of fired-heater convection sections, HRSGs and economisers. When to choose solid or serrated fins, which fin material for which tip temperature, and when studs or H-fins are the better answer.
3 min read
Heat-transfer tubes
Finned tube fouling and cleaning in Gulf dust
Dust, sand and salt clog air-cooler fins across the Gulf every summer, just when the coolers are working hardest. How fouling builds up on finned tube, how to clean it without flattening the fins, and the design choices that make the next bundle easier to keep clean.
2 min read
Heat-transfer tubes
Types of finned tubes: L, LL, KL, G-fin, extruded or welded?
Wound, embedded, extruded and welded fins differ in how the fin is held to the tube — and that bond sets the temperature, the corrosion protection and the price. How to choose a fin type for an air cooler, economiser or fired heater.
6 min read