Dixon Series 1 FRLs B74 Series Standard Filters/Regulators

Dixon Series 1 FRLs B74 Series Standard Filters/Regulators: 9 part numbers.
Product description
Dixon Series 1 FRLs B74 Series Standard Filters/Regulators: 9 part numbers.
Specification
- Type: Filter/Regulator
- Part numbers: 9
Sizes and part numbers
The Sizes & Part Numbers tab lists every Dixon part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Sizing air preparation
Size filters, regulators and lubricators on port size and the air flow the downstream tools and cylinders need, not on line size alone; an undersized unit drops pressure at full flow. Quote the maker part number and we will confirm bowl, drain and gauge options before supply.
How to order
Quote the Dixon part number. Price and lead time are confirmed with the quotation.
Shipping & lead time
Sizes & part numbers
9 sizes- Dixon Valve & Coupling part no.B74G-3MG-MB
- Description
- Filter-Regulator, Manual, Metal Bowl with Sight Glass
- Dixon Valve & Coupling part no.B74G-6AG
- Description
- Filter-Regulator, Auto, Transparent Bowl with Guard
- Dixon Valve & Coupling part no.B74G-6AG-MB
- Description
- Filter-Regulator, Auto, Metal Bowl with Sight Glass
- Dixon Valve & Coupling part no.B74G-4AG-MB
- Description
- Filter-Regulator, 1/2 inch Size, Auto, Metal Bowl, Sight Glass
- Dixon Valve & Coupling part no.B74G-6MG
- Description
- Filter-Regulator, Manual, Transparent Bowl with Guard
- Dixon Valve & Coupling part no.B74G-4MG-MB
- Description
- Filter-Regulator, 1/2 inch Size, Manual, Metal Bowl, Sight Glass
- Dixon Valve & Coupling part no.B74G-6MG-MB
- Description
- Filter-Regulator, Manual, Metal Bowl with Sight Glass
- Dixon Valve & Coupling part no.B74G-4AG
- Description
- Filter-Regulator, 1/2 inch Size, Auto, Transparent Bowl, Guard
Show all 9 sizesShow fewer sizes
- Dixon Valve & Coupling part no.B74G-4MG
- Description
- Filter-Regulator, 1/2 inch Size, Manual, Transparent Bowl, Guard
Description — What this part number is, as the manufacturer lists it. Ask us for the dimension drawing if you need it stamped.
What are the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators used for?▾
Which part numbers are in the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators range and how do they differ?▾
What port sizes and flow ratings does the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators come in?▾
How do I choose the right Dixon Series 1 FRLs B74 Series Standard Filters/Regulators part number?▾
What pressure rating and adjustment range does the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators have?▾
Which compressor oils and chemicals can damage the bowl of the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators?▾
Does the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators include a lubricator?▾
What should I connect to the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators?▾
How do I service the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators?▾
How does the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators differ from the Dixon Series 1 FRLs B07 Series Miniature Filters/Regulators range?▾
Where is the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators made and how is it shipped from Dubai?▾
Can I buy the Dixon Series 1 FRLs B74 Series Standard Filters/Regulators ex-stock from Indus in the UAE?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
FRL units explained: filter, regulator and lubricator — order, grades, drains, bowls and sizing
An FRL is the last thing compressed air passes through before it reaches a valve or cylinder. What each element does and why the order is filter, regulator, lubricator; particulate vs coalescing grades in microns; manual, semi-automatic and automatic drains; relieving regulators; when to lubricate; polycarbonate vs metal bowls; and sizing by flow, not port size.
17 min read
Pneumatics & compressed air
Compressed air quality and ISO 8573-1: purity classes, pressure dew point and where to fix the water
ISO 8573-1 writes air quality as three numbers — particles, water, oil. What [2:4:2] or [7:4:3] actually means, which classes food, paint, tools and valves are commonly specified at, why hot, humid air drops so much water once it is compressed and cooled, and why drains, coalescing filters and dryers — not the FRL at the machine — are where water is removed.
14 min read
Pneumatics & compressed air
How to size a pneumatic cylinder: force, load ratio, pressure at the port and air consumption
Theoretical force is pressure times piston area, and the return stroke only gets the annulus. How much margin Parker recommends, why to size on the pressure at the cylinder rather than the compressor, how to work out air per cycle in free air, a worked example in bar/mm and psi/inch, and force tables for common bores at 6 bar and 80 psi.
22 min read