Dixon H-Series ISO-B High Volume Female Plugs

Dixon H-Series ISO-B High Volume Female Plugs in brass, stainless steel, 1 1/4" to 1 1/2": 21 part numbers.
Product description
Dixon H-Series ISO-B High Volume Female Plugs in brass, stainless steel, 1 1/4" to 1 1/2": 21 part numbers.
Specification
- Type: Plug
- Material: Brass, Stainless Steel, Steel
- Size range: 1 1/4" to 1 1/2"
- Pressure stated by the maker: 700 to 2,500 psi (48 to 172 bar), by size
- Temperature: -40°F to +250°F
- Thread Type: Female NPTF
- Connection Type: Quick Disconnect x NPTF
- Part numbers: 21
Sizes and part numbers
The Sizes & Part Numbers tab lists every Dixon part number in this range with its connections. Ratings vary by size — check the row for the part you order.
Matching halves
Quick couplings only seal and flow at their rating when both halves come from the same interchange profile. Quote the part number of the mating half too, or tell us what it must connect to, and we will confirm the match before supply.
How to order
Quote the Dixon part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Connection Type | Quick Disconnect x NPTF |
| Finish | Trivalent Chrome Plated |
| Fitting Type | Plug |
| Gender | Female |
| Temp. | -40°F to +250°F |
| Thread Type | Female NPTF |
Shipping & lead time
Sizes & part numbers
21 sizes- Dixon Valve & Coupling part no.H12F12
- Description
- ISO-B Plug, NPTF Thread, 1-1/2 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H10F10
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/4"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H12BF12
- Description
- ISO-B Plug, BSPP Thread, 1-1/2 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H10BF10
- Description
- ISO-B Plug, BSPP Thread, 1-1/4 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/4"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H10F10-S
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, 303 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/4"
- Rated pressure (psi)
- 2,000
- Dixon Valve & Coupling part no.H12BF12-B
- Description
- ISO-B Plug, BSPP Thread, 1-1/2 Inch Thread, Brass
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,000
- Dixon Valve & Coupling part no.H10F10-B
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, Brass
- Type
- Nipple (male half)
- Body size
- 1 1/4"
- Rated pressure (psi)
- 1,000
- Dixon Valve & Coupling part no.H12BF12-SS
- Description
- ISO-B Plug, BSPP Thread, 1-1/2 Inch Thread, 316 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,000
Show all 21 sizesShow fewer sizes
- Dixon Valve & Coupling part no.H12F12-S
- Description
- ISO-B Plug, NPTF Thread, 1-1/2 Inch Thread, 303 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,500
- Dixon Valve & Coupling part no.H12BF12-S
- Description
- ISO-B Plug, BSPP Thread, 1-1/2 Inch Thread, 303 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,500
- Dixon Valve & Coupling part no.H12F10
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H12OF10
- Description
- ISO-B Plug, ORB Thread, 1-5/8 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H12F10-S
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, 303 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,500
- Dixon Valve & Coupling part no.H12OF12
- Description
- ISO-B Plug, ORB Thread, Thread Size 1-7/8 Inch, Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 2,500
- Dixon Valve & Coupling part no.H20F16-B
- Description
- ISO-B Plug, NPTF Thread, 2 Inch Thread, Brass
- Type
- Nipple (male half)
- Body size
- —
- Rated pressure (psi)
- 700
- Dixon Valve & Coupling part no.H12F12-SS
- Description
- ISO-B Plug, NPTF Thread, 1-1/2 Inch Thread, 316 Stainless Steel
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,000
- Dixon Valve & Coupling part no.H20F20
- Description
- ISO-B Plug, NPTF Thread, Thread 2-1/2 Inch Size, Steel
- Type
- Nipple (male half)
- Body size
- —
- Rated pressure (psi)
- 1,500
- Dixon Valve & Coupling part no.H20F16
- Description
- ISO-B Plug, NPTF Thread, 2 Inch Thread, Steel
- Type
- Nipple (male half)
- Body size
- —
- Rated pressure (psi)
- 1,500
- Dixon Valve & Coupling part no.H12F12-B
- Description
- ISO-B Plug, NPTF Thread, 1-1/2 Inch Thread, Brass
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,000
- Dixon Valve & Coupling part no.H12F10-B
- Description
- ISO-B Plug, NPTF Thread, 1-1/4 Inch Thread, Brass
- Type
- Nipple (male half)
- Body size
- 1 1/2"
- Rated pressure (psi)
- 1,000
- Dixon Valve & Coupling part no.H20F24
- Description
- ISO-B Plug, NPTF Thread, Thread 3 Inch Size, Steel
- Type
- Nipple (male half)
- Body size
- —
- Rated pressure (psi)
- 1,500
Description — What this part number is, as the manufacturer lists it. Type — Which part of the coupling this is: coupler (female half), nipple (male half), complete set, dust cap or adapter. Body size — Nominal body size of the coupling, which sets which halves mate. Rated pressure — Rated working pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is the Dixon H-Series ISO-B High Volume Female Plugs used for?▾
How do I read part numbers such as H12F12 on the Dixon H-Series ISO-B High Volume Female Plugs?▾
What sizes do the Dixon H-Series ISO-B High Volume Female Plugs come in?▾
What pressure are the Dixon H-Series ISO-B High Volume Female Plugs rated for?▾
What are the Dixon H-Series ISO-B High Volume Female Plugs made of?▾
Which interchange or standard do the Dixon H-Series ISO-B High Volume Female Plugs follow?▾
What do the Dixon H-Series ISO-B High Volume Female Plugs connect to and which half do they mate with?▾
How do I fit and use the Dixon H-Series ISO-B High Volume Female Plugs?▾
Where are the Dixon H-Series ISO-B High Volume Female Plugs used?▾
How do the Dixon H-Series ISO-B High Volume Female Plugs differ from the Dixon H-Series ISO-B High Volume Female Couplers?▾
Where are the Dixon H-Series ISO-B High Volume Female Plugs made and what is the HS code?▾
Do you stock the Dixon H-Series ISO-B High Volume Female Plugs in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Schnellkupplung Innengewinde
- fr
- raccord rapide femelle
- es
- acoplamiento rápido hembra
- it
- innesto rapido femmina
From the blog
Written about this range
Assembly, crimping & certification
Quick couplers: ISO 7241 A, B and flat-face, and why yours will not connect
Two couplers of the same nominal size, the same thread and the same brand will refuse to mate if one is Series A and the other Series B. Here is how to tell which you have before you order.
7 min read
Machine down
Tractors and implements: the couplers are older than the machine
Agricultural hydraulics run on a coupler standard that has barely changed in decades, which is why a 1990s implement still connects to a new tractor — and why grit gets into everything.
3 min read
Safety & HSE
Trapped pressure: why the coupler will not connect, and how to release it safely
An attachment left in the sun all morning can build enough pressure in a disconnected line to make a coupler impossible to push home. Forcing it is the part that hurts people.
5 min read