Thorburn Cryogenic CO₂ Connector — Dewar Transfer
Specialty Hose AssembliesEx-stock · delivery in 3 days

VIEW 01·Cryogenic CO₂ dewar transfer connector with brass cap and tether
1 / 2
Thorburn CO₂ transfer hose for dewar filling — helical or PTFE-lined to reduce snowballing, brass ACME CO₂ connections, 400 psi (27.6 bar).
Key features
- Hose Family: Cryogenic Assembly
- Core Material: Type 316L SS
- Nominal ID Range: DN 13 (1/2") to DN 25 (1")
- Max Working Pressure: 50 bar
- Hose Family
- Cryogenic Assembly
- Construction Type
- Annular Corrugated
- Braid Configuration
- Single Braid
- Core Material
- Type 316L SS
- Nominal ID Range
- DN 13 (1/2") to DN 25 (1")
- Max Working Pressure
- 50 bar
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer
Product description
A Thorburn cryogenic transfer hose for liquid CO₂ (dewar filling): braided corrugated stainless hose built for cryogenic unloading and transfer, with optional armour and a Cryo-Therm foam insulation cover.
Construction and ratings
- Maximum operating pressure 400 psi (27.6 bar) for Thorburn’s cryogenic unloading hose; high-pressure versions are available to 3,500 psi.
- Operating temperature −269 °C to 538 °C.
- Helical-lined (CGH66/CGH96) or PTFE-lined (CGTR40) models are designed to reduce snowballing in CO₂ transfer; CO₂ ends are brass ACME connectors.
- Cryo-Therm cover (−196 to 302 °C) cuts heat gain; Thorburn gives an example of 25 L of LN2 lost per fill on a bare hose against 2.5 L with the cover.
- Vacuum-jacketed cryogenic hose is a separate Thorburn design (TJHC) — ask if the duty needs it.
Applications
- Bulk tanker unloading to storage
- Plant and laboratory fill lines
- Dewar and cylinder filling
How to order
Send the bore, overall length, both end connections, the fluid, its pressure and temperature, and any certification the project needs. We will confirm the build with the maker and quote it.
Identification
| Parameter | Value |
|---|---|
| Hose Family | Cryogenic Assembly |
| Construction Type | Annular Corrugated |
| OEM Part Code | CRYO-CO2-DEWAR |
Construction
| Parameter | Value |
|---|---|
| Braid Configuration | Single Braid |
| Core Material | Type 316L SS |
| Braid Material | Type 304 SS |
| End Fitting Material | CGA-320 dewar coupler (one end) and 316L SS NPT (other end) |
Dimensions
| Parameter | Value |
|---|---|
| Nominal ID Range | DN 13 (1/2") to DN 25 (1") |
| Bend Radius (Static) | 200 mm |
| Bend Radius (Dynamic) | 600 mm |
| Live Length for Vibration | 200 mm |
| Weight | 1.2 kg/m |
Performance
| Parameter | Value |
|---|---|
| Max Working Pressure | 50 bar |
| Min Burst Pressure | 200 bar |
| Safety Factor | 4 |
| Min Operating Temperature | -78 °C |
| Max Operating Temperature | 60 °C |
Compliance
| Parameter | Value |
|---|---|
| PED 2014/68/EU Module | Module H |
| ASME Compliance | ASME B31.3, Section IX |
| NACE MR0175 / ISO 15156 | no |
| CGA / UL / Chlorine Institute Certs | CGA-320, UL536 |
Shipping & lead time
Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.
OriginMade in Canada
What is the Thorburn Cryogenic CO₂ Connector, Dewar Transfer used for?▾
A Thorburn cryogenic transfer hose for liquid CO₂ (dewar filling) : braided corrugated stainless hose built for cryogenic unloading and transfer, with optional armour and a Cryo-Therm foam insulation cover. Typical uses include bulk tanker unloading to storage, plant and laboratory fill lines and dewar and cylinder filling. See the specialty hose assemblies.
What pressure and temperature can the Thorburn Cryogenic CO₂ Connector, Dewar Transfer take?▾
The Thorburn Cryogenic CO₂ Connector, Dewar Transfer has maximum operating pressure 400 psi (27.6 bar) for Thorburn’s cryogenic unloading hose; high-pressure versions are available to 3,500 psi; operating temperature −269 °C to 538 °C.
What is the Thorburn Cryogenic CO₂ Connector, Dewar Transfer made of?▾
The Thorburn Cryogenic CO₂ Connector, Dewar Transfer: Maximum operating pressure 400 psi (27.6 bar) for Thorburn’s cryogenic unloading hose; high-pressure versions are available to 3,500 psi. Operating temperature −269 °C to 538 °C.
Thorburn Cryogenic CO₂ Connector, Dewar Transfer: what is the typical service life and maintenance schedule?▾
Vacuum-jacketed cryogenic assemblies: 5-10 year service life with re-evacuation every 18-24 months. Replace inner gasket and outer pump-out valve at each re-evacuation.
Thorburn Cryogenic CO₂ Connector, Dewar Transfer: what end fittings are used?▾
CGA-320 dewar coupler (one end) and 316L SS NPT (other end). End-fitting alloy is typically matched to the inner core for severe service. For cryogenic assemblies, vacuum-jacketed bayonet or threaded couplers are standard; for steam-jacketed assemblies, the inner and outer hoses are sealed at independent flanged ports.
What do I send to order the Thorburn Cryogenic CO₂ Connector, Dewar Transfer?▾
To order the Thorburn Cryogenic CO₂ Connector, Dewar Transfer, send the bore, overall length, both end connections, the fluid, its pressure and temperature, and any certification the project needs. We will confirm the build with the maker and quote it.
Thorburn Cryogenic CO₂ Connector, Dewar Transfer: how is the cryogenic insulation maintained?▾
The vacuum-jacketed outer hose maintains insulation against ambient heat ingress. A super-insulator (typically multi-layer aluminized mylar) wraps the inner process hose; the outer jacket is evacuated to <10⁻⁵ torr. Re-evacuation is recommended every 18-24 months to maintain rated boil-off performance.
What else should I know about the Thorburn Cryogenic CO₂ Connector, Dewar Transfer?▾
Helical-lined (CGH66/CGH96) or PTFE-lined (CGTR40) models are designed to reduce snowballing in CO₂ transfer; CO₂ ends are brass ACME connectors. Cryo-Therm cover (−196 to 302 °C) cuts heat gain; Thorburn gives an example of 25 L of LN2 lost per fill on a bare hose against 2.5 L with the cover. Vacuum-jacketed cryogenic hose is a separate Thorburn design (TJHC) — ask if the duty needs it.
what standards / certifications does the Thorburn Cryogenic CO₂ Connector, Dewar Transfer meet?▾
ISO 10380:2012. PED 2014/68/EU Module H. ASME B31.3, Section IX. CGA-320, UL536. EN 10204 3.1 / 3.2 mill test reports. Send us the details and we confirm the specification before supply.
Where is the Thorburn Cryogenic CO₂ Connector, Dewar Transfer typically used?▾
The Thorburn Cryogenic CO₂ Connector, Dewar Transfer has several listed uses. Listed uses: bulk tanker unloading to storage; plant and laboratory fill lines; dewar and cylinder filling.
can the Thorburn Cryogenic CO₂ Connector, Dewar Transfer be supplied as part of a complete skid / cart?▾
Yes — Indus supplies complete turnkey skids and carts integrating these assemblies with matched valves, instrumentation, control panels, and structural framing. Specify the duty (e.g., chlorine rail-loading cart, asphalt steam-jacket header, cryogenic LNG unloading cart) on the RFQ for a complete proposal.
Is the Thorburn Cryogenic CO₂ Connector, Dewar Transfer in stock in Dubai?▾
Yes. We keep the Thorburn Cryogenic CO₂ Connector, Dewar Transfer in stock at our warehouse in Dubai, UAE, and ship worldwide with the best lead times. Builds are quoted per bore, length and end connection. Send the part numbers and quantities through our contact page for a quotation.
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
Also known as
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Met-O-Seal
- fr
- Met-O-Seal
- es
- Met-O-Seal
- it
- Met-O-Seal