Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option)
Specialty Hose AssembliesEx-stock · delivery in 3 days

VIEW 01·Hazardous-area heated metallic hose, 2 in, with heat-trace labels
1 / 2
Thorburn Sure-Temp electrically heated metal hose, 2 in — available with FM approval for Class I, Division 2, Group D areas; typical design to 300 psi (20 bar).
Key features
- Hose Family: Electrically-Heated Assembly
- Core Material: Type 316L SS
- Nominal ID Range: DN 50 (2")
- Max Working Pressure: 25 bar
- Hose Family
- Electrically-Heated Assembly
- Construction Type
- Annular Corrugated
- Braid Configuration
- Double Braid
- Core Material
- Type 316L SS
- Nominal ID Range
- DN 50 (2")
- Max Working Pressure
- 25 bar
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer
Product description
The Thorburn Sure-Temp 2 in electrically heated metal hose, offered with Factory Mutual approval for Class I, Division 2, Group D hazardous locations.
Construction and ratings
- Spiral MI-cable heating element, 100 Ω Pt RTD and programmable controller.
- Liquid service 5–250 °C; gas analysis service 5–450 °C.
- Typical design pressure full vacuum to 300 psi (20 bar).
- The maker states FM Class I Div 2 Group D approval; confirm any ATEX or IECEx zone requirement before ordering.
Applications
- Heated transfer in classified areas of refineries and chemical plants
- Bitumen and heavy-oil transfer
How to order
Send the bore, overall length, both end connections, the fluid, its pressure and temperature, and any certification the project needs. We will confirm the build with the maker and quote it.
Identification
| Parameter | Value |
|---|---|
| Hose Family | Electrically-Heated Assembly |
| Construction Type | Annular Corrugated |
| OEM Part Code | SURETEMP-EX-2 |
Construction
| Parameter | Value |
|---|---|
| Braid Configuration | Double Braid |
| Core Material | Type 316L SS |
| Braid Material | Type 304 SS |
| End Fitting Material | ANSI 150# RF flanged; ATEX/IECEx-rated electrical entry |
Dimensions
| Parameter | Value |
|---|---|
| Nominal ID Range | DN 50 (2") |
| Bend Radius (Static) | 200 mm |
| Bend Radius (Dynamic) | 500 mm |
| Live Length for Vibration | 200 mm |
| Weight | 3 kg/m |
Performance
| Parameter | Value |
|---|---|
| Max Working Pressure | 25 bar |
| Min Burst Pressure | 100 bar |
| Safety Factor | 4 |
| Min Operating Temperature | 0 °C |
| Max Operating Temperature | 200 °C |
Compliance
| Parameter | Value |
|---|---|
| PED 2014/68/EU Module | Module H |
| ASME Compliance | ASME B31.3 |
| NACE MR0175 / ISO 15156 | no |
| CGA / UL / Chlorine Institute Certs | UL536, ATEX II 2 G Ex db IIB+H₂ T3, IECEx Zone 1 |
Shipping & lead time
Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.
OriginMade in Canada
What is the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) used for?▾
The Thorburn Sure-Temp 2 in electrically heated metal hose, offered with Factory Mutual approval for Class I, Division 2, Group D hazardous locations. Typical uses include heated transfer in classified areas of refineries and chemical plants and bitumen and heavy-oil transfer. See the specialty hose assemblies.
What pressure and temperature can the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) take?▾
The Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) has typical design pressure full vacuum to 300 psi (20 bar).
What is the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) made of?▾
The Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option): Spiral MI-cable heating element, 100 Ω Pt RTD and programmable controller. Liquid service 5–250 °C; gas analysis service 5–450 °C.
Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option): what is the typical service life and maintenance schedule?▾
Electrically-heated assemblies: 7-10 year service life. Annual electrical safety / megger test on the heating element; replace thermostat if drift > 5°C from setpoint.
Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option): what end fittings are used?▾
ANSI 150# RF flanged; ATEX/IECEx-rated electrical entry. End-fitting alloy is typically matched to the inner core for severe service. For cryogenic assemblies, vacuum-jacketed bayonet or threaded couplers are standard; for steam-jacketed assemblies, the inner and outer hoses are sealed at independent flanged ports.
What do I send to order the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option)?▾
To order the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option), send the bore, overall length, both end connections, the fluid, its pressure and temperature, and any certification the project needs. We will confirm the build with the maker and quote it.
Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option): how does the electric heat tracing work?▾
The Sure-Temp heating element is integrated within the hose construction (typically a self-regulating heating cable wrapped around the inner core, beneath an insulating jacket). A thermostat senses process temperature and modulates power to maintain setpoint. Power supply: 110-240 VAC, with optional explosion-proof / hazardous-area variants.
What else should I know about the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option)?▾
Typical design pressure full vacuum to 300 psi (20 bar). The maker states FM Class I Div 2 Group D approval; confirm any ATEX or IECEx zone requirement before ordering.
what standards / certifications does the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) meet?▾
ISO 10380:2012. PED 2014/68/EU Module H. ASME B31.3. UL536, ATEX II 2 G Ex db IIB+H₂ T3, IECEx Zone 1. EN 10204 3.1 / 3.2 mill test reports.
Where is the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) typically used?▾
The Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) has several listed uses. Listed uses: heated transfer in classified areas of refineries and chemical plants; bitumen and heavy-oil transfer.
Is the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) built to order, and what is the delivery?▾
The Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) is quoted per build: the listing says to send the bore, length, end connections, fluid, pressure and temperature. And Indus confirms the build with the maker and quotes it. The listing gives Canada as the country of origin. We ship from Dubai, UAE to the GCC, Africa, Asia and beyond.
Is the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) in stock in Dubai?▾
Yes, we carry the Thorburn Sure-Temp Electrically-Heated Hose, 2 in (FM Class I Div 2 option) in stock at our warehouse in Dubai, UAE, and ship worldwide with the best lead times. Builds are quoted per bore, length and end connection. Request pricing for your sizes through our contact page.
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
Also known as
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Met-O-Seal
- fr
- Met-O-Seal
- es
- Met-O-Seal
- it
- Met-O-Seal
From the blog
Written about this part
RELATED · OFTEN PAIRED WITH