SUN HYDRAULICSIH-SUN-FC-BC

Sun Hydraulics Fixed-Orifice Pressure Compensated Flow Control Valve with Reverse Flow Check — FCBB to FCFB, Series 0 to 4

Flow Control CartridgesEx-stock · delivery in 3 days
Sun Hydraulics FCCC fixed-orifice pressure-compensated flow control valve, series 1, T-13A cavity — dimension drawing
VIEW 01·Sun Hydraulics FCCC fixed-orifice pressure-compensated flow control valve, series 1, T-13A cavity — dimension drawing
1 / 3

Sun Hydraulics fixed-orifice pressure-compensated flow control valve: FCBB to FCFB, series 0 to 4, 3 gpm to 50 gpm (11 L/min to 200 L/min), T-162A, T-13A, T-5A, T-16A, T-18A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Fixed-Orifice Pressure-Compensated Flow Control Valve
  • Capacity: 3 gpm to 50 gpm (11 L/min to 200 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-162A, T-13A, T-5A, T-16A, T-18A
Valve function
Fixed-Orifice Pressure-Compensated Flow Control Valve
Series (frame sizes)
0 to 4
Cavity
T-162A, T-13A, T-5A, T-16A, T-18A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A pressure-compensated flow control with its flow set at the factory, for meter-in or meter-out speed control under changing pressure. Versions with a reverse-flow check pass return oil freely from port 2 to port 1.

Sizes and cavities

Sun Hydraulics builds this valve in 8 sizes. The series sets the cavity it screws into and its flow capacity:

  • FCBB — series 0, T-162A cavity, 3 gpm (11 L/min), 0-series
  • FCBC — series 0, T-162A cavity, 3 gpm (11 L/min), 0-series
  • FCCB — series 1, T-13A cavity, 6 gpm (23 L/min)
  • FCCC — series 1, T-13A cavity, 6 gpm (23 L/min)
  • FCDB — series 2, T-5A cavity, 12 gpm (45 L/min)
  • FCDC — series 2, T-5A cavity, 12 gpm (45 L/min)
  • FCEB — series 3, T-16A cavity, 25 gpm (95 L/min)
  • FCFB — series 4, T-18A cavity, 50 gpm (200 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)

Configuration options

The letters after the base model code choose these options (shown for FCCC; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, X — Not Adjustable
  • Setting range: A — .09 - .12 gpm (.34-.46 L/min.), .11 gpm (.4 L/min.) Standard Setting, B — .12 - .17 gpm (.47-.63 L/min.), .15 gpm (.55 L/min.) Standard Setting, C — .17 - .23 gpm (.64-.86 L/min.), .20 gpm (.75 L/min.) Standard Setting, D — .25 - .33 gpm (.94-1.27 L/min.), .29 gpm (1.10 L/min.) Standard Setting, F — .35 - .47 gpm (1.32-1.78 L/min.), .41 gpm (1.55 L/min.) Standard Setting, G — .45 - .61 gpm (1.70-2.30 L/min.), .53 gpm (2.0 L/min.) Standard Setting, H — .56 - .76 gpm (2.13-2.88 L/min.), .66 gpm (2.5 L/min.) Standard Setting, J — .7 - .94 gpm (2.64-3.57 L/min.), .82 gpm (3.10 L/min.) Standard Setting, K — .85 - 1.15 gpm (3.23-4.37 L/min.), 1.0 gpm (3.80 L/min.) Standard Setting, L — 1.09 - 1.47 gpm (4.12-5.58 L/min.), 1.28 gpm (4.85 L/min.) Standard Setting, M — 1.35 - 1.82 gpm (5.10-6.90 L/min.), 1.59 gpm (6.0 L/min.) Standard Setting, N — 1.68 - 2.28 gpm (6.38-8.63 L/min.), 1.98 gpm (7.50 L/min.) Standard Setting, P — 2.08 - 2.81 gpm (7.86-10.64 L/min.), 2.44 gpm (9.25 L/min.) Standard Setting, R — 2.58 - 3.49 gpm (9.78-13.23 L/min.), 3.04 gpm (11.5 L/min.) Standard Setting, S — 3.19 - 4.31 gpm (12.07-16.33 L/min.), 3.75 gpm (14.2 L/min.) Standard Setting, T — 3.93 - 5.32 gpm (14.88-20.13 L/min.), 4.62 gpm (17.5 L/min.) Standard Setting, V — 4.94 - 6.68 gpm (18.70-25.30 L/min.), 5.81 gpm (22.0 L/min.) Standard Setting
  • Seal material: L — Extended Temp. Buna, N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated

Option rules: EPDM seals are not allowed on modifier /AP; If the modifier is /AP, the control must be C or L.

Selection notes

  • You specify the flow; it is factory set.
  • A tuneable option allows field trimming.

Where it is used

Fixed actuator speeds on production machinery and mobile functions.

Installation and seal kits

Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990162007, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990010007, Polyurethane: 990010002, Viton: 990010006; series 2: Buna: 990203007, Viton: 990203006; series 3: Buna: 990016007, Polyurethane: 990016002, Viton: 990016006; series 4: Buna: 990018007, Polyurethane: 990018002, Viton: 990018006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FCCCXAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionFixed-Orifice Pressure-Compensated Flow Control Valve
Series (frame sizes)0 to 4
CavityT-162A, T-13A, T-5A, T-16A, T-18A

Performance

ParameterValue
Capacity3 gpm to 50 gpm (11 L/min to 200 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — .09 - .12 gpm (.34-.46 L/min.), .11 gpm (.4 L/min.) Standard Setting, B — .12 - .17 gpm (.47-.63 L/min.), .15 gpm (.55 L/min.) Standard Setting, C — .17 - .23 gpm (.64-.86 L/min.), .20 gpm (.75 L/min.) Standard Setting, D — .25 - .33 gpm (.94-1.27 L/min.), .29 gpm (1.10 L/min.) Standard Setting, F — .35 - .47 gpm (1.32-1.78 L/min.), .41 gpm (1.55 L/min.) Standard Setting, G — .45 - .61 gpm (1.70-2.30 L/min.), .53 gpm (2.0 L/min.) Standard Setting, H — .56 - .76 gpm (2.13-

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, X — Not Adjustable
Seal materialL — Extended Temp. Buna, N — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated

Installation

ParameterValue
Valve hex size3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 0: Buna: 990162007, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990010007, Polyurethane: 990010002, Viton: 990010006; series 2: Buna: 990203007, Viton: 990203006; series 3: Buna: 990016007, Polyurethane: 990016002, Viton: 990016006; series 4: Buna: 990018007, Polyurethane: 990018002, Viton: 990018006
Weight.30 lb (0,15 kg) to 1.00 lb (0,45 kg)