Sun Hydraulics Electro-Proportional 3-Way Flow Control Valve, Meter In — FMDA, FMDB, Series 1

Sun Hydraulics electro-proportional 3-way meter-in flow control: FMDA, FMDB, series 1, 6 gpm to 9 gpm (23 L/min to 34 L/min), T-11A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Electro-Proportional 3-Way Meter-In Flow Control
- Capacity: 6 gpm to 9 gpm (23 L/min to 34 L/min)
- Cavity: T-11A
- Valve function
- Electro-Proportional 3-Way Meter-In Flow Control
- Series (frame sizes)
- 1
- Cavity
- T-11A
Product description
A 3-way, meter-in proportional throttle. With the coil off, the supply at port 1 is blocked and port 2 drains to tank at port 3; current opens a metering orifice from 1 to 2 in proportion to command. Add an external compensator for pressure-compensated control.
Sizes and cavities
Sun Hydraulics builds this valve in 2 sizes. The series sets the cavity it screws into and its flow capacity:
- FMDB — series 1, T-11A cavity, 6 gpm (23 L/min)
- FMDA — series 1, T-11A cavity, 9 gpm (34 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar)
Configuration options
The letters after the base model code choose these options (shown for FMDA; a size may add or drop a choice):
- Control: D — Twist/Lock (Dual) Manual Override, E — Twist (Extended) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override
- Seal material: N — Buna-N, V — Viton, E — EPDM
Option rules: If the coil is in this group (HN24AA, HN24AB), the control must be M or X; If the seal is E, the control must be D,E,L,M,T or X.
Selection notes
- Return flow from 2 to 3 is not proportional and is limited (about 1.5 gpm, 6 L/min).
- 740-Series coil versions are listed separately.
Where it is used
Meter-in speed control of single-acting functions and pilot-operated main stages.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990411007, Viton: 990411006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FMDAXDN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Electro-Proportional 3-Way Meter-In Flow Control |
| Series (frame sizes) | 1 |
| Cavity | T-11A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 6 gpm to 9 gpm (23 L/min to 34 L/min) |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | D — Twist/Lock (Dual) Manual Override, E — Twist (Extended) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm) |
| Seal kits | series 1: Buna: 990411007, Viton: 990411006 |
Shipping & lead time
Sizes & part numbers
2 sizes- Sun Hydraulics part no.FMDB
- Series
- 1
- Cavity
- T-11A
- Capacity
- 6 gpm / 23 L/min
- Sun Hydraulics part no.FMDA
- Series
- 1
- Cavity
- T-11A
- Capacity
- 9 gpm / 34 L/min
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control used for?▾
Which sizes and versions does the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control come in?▾
How do I read the Sun Hydraulics model code FMDAXDN for the FMDA, FMDB electro-proportional 3-way meter-in flow control?▾
What is the maximum operating pressure of the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control?▾
What flow capacity does the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control have by series?▾
Which seal materials and body finishes does the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control come with?▾
Which cavity does the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control fit?▾
Which seal kit fits the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control?▾
How is the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control installed?▾
Where is the Sun Hydraulics FMDA, FMDB electro-proportional 3-way meter-in flow control used?▾
Sun Hydraulics FMDA, FMDB or FMDF, FMDG: what is the difference?▾
Do you stock the Sun Hydraulics FMDA, FMDB in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations