Sun Hydraulics 2-Way, Manually Operated, Directional Poppet Valve with Overlap — DTCM

Sun Hydraulics 2-Way, Manually Operated, Directional Poppet Valve with Overlap: DTCM, series 1, 6 gpm (23 L/min), T-13A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Manually Operated Directional Valve
- Capacity: 6 gpm (23 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-13A
- Valve function
- Manually Operated Directional Valve
- Series (frame sizes)
- 1
- Cavity
- T-13A
Product description
A screw-in directional cartridge shifted by hand. A twist-lock or push operator moves the poppet or spool, so a function can be worked, overridden or isolated without electrical power.
This version
- Overlap design: a combined seat and spool stops the small pass of oil that many poppet valves let through when the pressure across them changes suddenly.
Sizes and cavities
Sun Hydraulics builds this valve in one version:
- DTCM — series 1, T-13A cavity, 6 gpm (23 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
Configuration options
The letters after the base model code choose these options (shown for DTCM; a size may add or drop a choice):
- Control: D — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, T — Twist (Momentary) Manual Override
- Spool / poppet configuration: C — Normally Closed
- Seal material: N — Buna-N, V — Viton
Selection notes
- The manual operator is for occasional use — Sun quotes a life of about 10,000 cycles — and can be replaced in the field without removing the cartridge.
- A momentary twist option returns to the rest position as soon as it is released.
Where it is used
Manual overrides, set-up and maintenance functions, emergency lowering, isolating a branch.
Installation and seal kits
Hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990413007, Polyurethane: 990413002, Viton: 990413006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DTCMLCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 6 gpm (23 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Max leakage | 10 drops/min.@5000 psi (0,7 cc/min.@350 bar) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Manually Operated Directional Valve |
| Series (frame sizes) | 1 |
| Cavity | T-13A |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | D — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, T — Twist (Momentary) Manual Override; C — Normally Closed |
| Seal material | N — Buna-N, V — Viton |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm) |
| Seal kits | series 1: Buna: 990413007, Polyurethane: 990413002, Viton: 990413006 |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.DTCM
- Series
- 1
- Cavity
- T-13A
- Capacity
- 6 gpm / 23 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics DTCM manually operated directional valve used for?▾
Which sizes and versions does the Sun Hydraulics DTCM manually operated directional valve come in?▾
How do I read the Sun Hydraulics model code DTCMLCN for the DTCM manually operated directional valve?▾
What is the maximum operating pressure of the Sun Hydraulics DTCM manually operated directional valve?▾
What flow capacity does the DTCM manually operated directional valve have?▾
Which seal materials and body finishes does the Sun Hydraulics DTCM manually operated directional valve come with?▾
Which cavity does the Sun Hydraulics DTCM manually operated directional valve fit?▾
Which seal kit fits the Sun Hydraulics DTCM manually operated directional valve?▾
How is the Sun Hydraulics DTCM manually operated directional valve installed?▾
Where is the Sun Hydraulics DTCM manually operated directional valve used?▾
Sun Hydraulics DTCM or DTDM: what is the difference?▾
Do you stock the Sun Hydraulics DTCM in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations