Split Flange Clamps Code 62 (Pair + Bolts)

Split-flange clamp halves + Grade 8 bolt set per SAE J518 Code 62 — high-pressure 4-bolt mounting up to 415 bar. SAE J518 Code 62 (415 bar), 1/2" – 2" (high-pressure series limit).
Key features
- Flange Type: split-clamp
- SAE J518 Code: code-62
- Configuration: clamp-only
- Nominal Size Range: 1/2" – 2" (high-pressure series limit)
- Max Working Pressure: up to 415 bar (6000 psi)
- Flange Type
- split-clamp
- SAE J518 Code
- code-62
- Configuration
- clamp-only
- Nominal Size Range
- 1/2" – 2" (high-pressure series limit)
- Max Working Pressure
- up to 415 bar (6000 psi)
Product description
The Split Flange Clamps Code 62 (Pair + Bolts) is a Split Flange Clamp per SAE J518 Code 62 (high-pressure, up to 415 bar / 6000 psi) — mounting hardware (split clamp halves + bolts).
Construction
- Type: Split Flange Clamp
- Code: SAE J518 Code 62 (high pressure)
- Configuration: clamp-only
- Bolt pattern: SAE J518 Code 62 4-bolt; bolts SAE J429 Grade 8
- Size range: 1/2" – 2" (high-pressure series limit)
- Material: Carbon steel (stainless steel available on request)
- Surface treatment: Zinc-plated, Cr3+ passivated, RoHS-compliant
- Notes: Sold per joint (2 clamp halves + 4 bolts + washers). Pair with Indus Code 62 flange-on-fitting variants.
Performance
Working pressure up to 415 bar (6000 psi). Operating temperature -40°C to +120°C. Sealed by a face O-ring under the flange head — no thread sealing required.
Applicable Standards
- SAE J518 Code 62
- ISO 6162-2
How to order
Specify (a) the flange port size on your equipment, (b) the matching flange-on-fitting (Supercat / Code 62 / Code 61), and (c) for hose assemblies the host hose grade and overall length. Indus crimps and pressure-tests the assembly before dispatch.
Companion products
Pair with Indus Supercat / Code 62 / Code 61 flange-on-fitting variants.
Identification
| Parameter | Value |
|---|---|
| Flange Type | split-clamp |
| SAE J518 Code | code-62 |
| Configuration | clamp-only |
Dimensions
| Parameter | Value |
|---|---|
| Nominal Size Range | 1/2" – 2" (high-pressure series limit) |
Performance
| Parameter | Value |
|---|---|
| Max Working Pressure | up to 415 bar (6000 psi) |
Construction
| Parameter | Value |
|---|---|
| Bolt Pattern | SAE J518 Code 62 4-bolt; bolts SAE J429 Grade 8 |
| Material | Carbon steel (stainless on request) |
| Surface Treatment | Zinc-plated, Cr3+ passivated, RoHS-compliant |
Compliance
| Parameter | Value |
|---|---|
| Applicable Standards | SAE J518 Code 62, ISO 6162-2 |
Shipping & lead time
Sizes & part numbers
6 sizes- Indus part no.IH-FL-CLAMP-62-08
- Hose bore
- -08 · 1/2"
- Size
- 1/2" M8×30 18.2
- A (mm)
- 56.3
- B (mm)
- 49.2
- C (mm)
- 40.5
- D (mm)
- 9
- Indus part no.IH-FL-CLAMP-62-12
- Hose bore
- -12 · 3/4"
- Size
- 3/4" M10×35 23.8
- A (mm)
- 71.4
- B (mm)
- 61.8
- C (mm)
- 50.8
- D (mm)
- 11
- Indus part no.IH-FL-CLAMP-62-16
- Hose bore
- -16 · 1"
- Size
- 1" M12×45 27.8
- A (mm)
- 81
- B (mm)
- 71.4
- C (mm)
- 57.2
- D (mm)
- 11
- Indus part no.IH-FL-CLAMP-62-20
- Hose bore
- -20 · 1.1/4"
- Size
- 1.1/4" M14×50 31.8
- A (mm)
- 95.3
- B (mm)
- 79.2
- C (mm)
- 66.7
- D (mm)
- 11
- Indus part no.IH-FL-CLAMP-62-24
- Hose bore
- -24 · 1.1/2"
- Size
- 1.1/2" M16×55 36.6 42
- A (mm)
- 112.8
- B (mm)
- 96.8
- C (mm)
- 79.4
- D (mm)
- 13.5
- Indus part no.IH-FL-CLAMP-62-32
- Hose bore
- -32 · 2"
- Size
- 2" M20×70 44.4
- A (mm)
- 133.4
- B (mm)
- 114
- C (mm)
- 96.8
- D (mm)
- 13.5
A — Dimension A on the manufacturer dimension drawing. B — Dimension B on the manufacturer dimension drawing. C — Dimension C on the manufacturer dimension drawing. D — Dimension D on the manufacturer dimension drawing. Ask us for the dimension drawing if you need it stamped.
Every size is available in 316 stainless steel on request — add “-SS” to the part number when you enquire.
What is the Split Flange Clamps Code 62 (Pair + Bolts) and which SAE J518 code is it?▾
What are the part numbers of the Split Flange Clamps Code 62 (Pair + Bolts)?▾
What sizes does the Split Flange Clamps Code 62 (Pair + Bolts) come in?▾
Which flange sizes are listed for the Split Flange Clamps Code 62 (Pair + Bolts)?▾
What pressure and temperature is the Split Flange Clamps Code 62 (Pair + Bolts) rated for?▾
What is the Split Flange Clamps Code 62 (Pair + Bolts) made from, and is stainless steel available?▾
Which standards and bolt pattern does the Split Flange Clamps Code 62 (Pair + Bolts) follow?▾
Which flange fittings does the Split Flange Clamps Code 62 (Pair + Bolts) go with?▾
Are the bolts included with the Split Flange Clamps Code 62 (Pair + Bolts)?▾
Can I use the Split Flange Clamps Code 62 (Pair + Bolts) on a Code 61 port?▾
How does the Split Flange Clamps Code 62 (Pair + Bolts) differ from the Split Flange Clamps Code 61 (Pair + Bolts)?▾
Can I buy the Split Flange Clamps Code 62 (Pair + Bolts) from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Flansch
- fr
- bride
- es
- brida
- it
- flangia