SMC TL Series Fluoropolymer Tubing

SMC TL Series Fluoropolymer Tubing: 13 part numbers.
Product description
SMC TL Series Fluoropolymer Tubing: 13 part numbers.
Specification
- Type: Tubing
- Working pressure stated by the maker at room temperature: 7 to 10 bar (about 100 to 145 psi), on the sizes the maker rates
- Part numbers: 13
Sizes and part numbers
The Sizes & Part Numbers tab lists every SMC part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Choosing the tubing
Select tubing on outside diameter for the push-in fittings it must fit, wall and material for pressure and temperature, and colour for circuit identification. Working pressure falls as temperature rises — check the maker rating at the operating temperature.
How to order
Quote the SMC part number. Price and lead time are confirmed with the quotation.
Shipping & lead time
Sizes & part numbers
13 sizes- SMC part no.TL1008-10
- I.D. (mm)
- 8
- Wall (mm)
- 1
- Description
- SMC TL Super PFA tube, 10 × 8 mm, 10 m roll
- Tube O.D. (mm)
- 10
- Working pressure (bar)
- —
- SMC part no.TL0403-20
- I.D. (mm)
- 3
- Wall (mm)
- 0.5
- Description
- SMC TL Super PFA tube, 4 × 3 mm, 20 m roll
- Tube O.D. (mm)
- 4
- Working pressure (bar)
- 10
- SMC part no.TL1916-100
- I.D. (mm)
- 16
- Wall (mm)
- 1.5
- Description
- SMC TL Super PFA tube, 19 × 16 mm, 100 m roll
- Tube O.D. (mm)
- 19
- Working pressure (bar)
- —
- SMC part no.TL1210-10
- I.D. (mm)
- 10
- Wall (mm)
- 1
- Description
- SMC TL Super PFA tube, 12 × 10 mm, 10 m roll
- Tube O.D. (mm)
- 12
- Working pressure (bar)
- 7
- SMC part no.TLM0806R-20
- I.D. (mm)
- 6
- Wall (mm)
- 1
- Description
- SMC TLM PFA tube, 8 × 6 mm, red, 20 m roll
- Tube O.D. (mm)
- 8
- Working pressure (bar)
- —
- SMC part no.TLM1008N-20
- I.D. (mm)
- 8
- Wall (mm)
- 1
- Description
- SMC TLM PFA tube, 10 × 8 mm, translucent, 20 m roll
- Tube O.D. (mm)
- 10
- Working pressure (bar)
- 7
- SMC part no.TL0806-50
- I.D. (mm)
- 6
- Wall (mm)
- 1
- Description
- SMC TL Super PFA tube, 8 × 6 mm, 50 m roll
- Tube O.D. (mm)
- 8
- Working pressure (bar)
- 9
- SMC part no.TL0403-50
- I.D. (mm)
- 3
- Wall (mm)
- 0.5
- Description
- SMC TL Super PFA tube, 4 × 3 mm, 50 m roll
- Tube O.D. (mm)
- 4
- Working pressure (bar)
- 10
Show all 13 sizesShow fewer sizes
- SMC part no.TLM0806N-20
- I.D. (mm)
- 6
- Wall (mm)
- 1
- Description
- SMC TLM PFA tube, 8 × 6 mm, translucent, 20 m roll
- Tube O.D. (mm)
- 8
- Working pressure (bar)
- —
- SMC part no.TL0604-50
- I.D. (mm)
- 4
- Wall (mm)
- 1
- Description
- SMC TL Super PFA tube, 6 × 4 mm, 50 m roll
- Tube O.D. (mm)
- 6
- Working pressure (bar)
- 10
- SMC part no.TLM0302N-20
- I.D. (mm)
- 2
- Wall (mm)
- 0.5
- Description
- SMC TLM PFA tube, 3 × 2 mm, translucent, 20 m roll
- Tube O.D. (mm)
- 3
- Working pressure (bar)
- 10
- SMC part no.TLM0403BU-20
- I.D. (mm)
- 3
- Wall (mm)
- 0.5
- Description
- SMC TLM PFA tube, 4 × 3 mm, blue, 20 m roll
- Tube O.D. (mm)
- 4
- Working pressure (bar)
- 10
- SMC part no.TLM0806BU-20
- I.D. (mm)
- 6
- Wall (mm)
- 1
- Description
- SMC TLM PFA tube, 8 × 6 mm, blue, 20 m roll
- Tube O.D. (mm)
- 8
- Working pressure (bar)
- —
I.D. (mm) — Inside diameter in millimetres with its tolerance, as published. Wall (mm) — Wall thickness in millimetres, as published — a single figure or a band. Description — What this part number is, as the manufacturer lists it. Tube O.D. — Outside diameter of the tube the port is cut for. Ask us for the dimension drawing if you need it stamped.
Working pressure is the manufacturer’s published rating for the fitting itself. An assembly is limited by its lowest-rated component, so check it against the hose, the tube and the port you are mating to.
What is SMC TL series fluoropolymer tubing?▾
How do you read an SMC TL part number such as TL0604-50 or TLM0806R-20?▾
What sizes does SMC TL fluoropolymer tubing come in?▾
Which SMC TL size suits a 6 mm or 8 mm push-in fitting?▾
What is the working pressure of SMC TL fluoropolymer tubing?▾
What chemicals can SMC TL Super PFA tubing carry?▾
Does SMC TL fluoropolymer tubing comply with RoHS?▾
Which fittings work with SMC TL fluoropolymer tubing?▾
How should SMC TL tubing be routed and inspected?▾
What is the difference between SMC TL and TLM fluoropolymer tubing?▾
Where is SMC TL fluoropolymer tubing shipped from?▾
Is SMC TL fluoropolymer tubing available from stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Pneumatic tubing materials: nylon, polyurethane, polyolefin and fluoropolymer compared
Nylon holds pressure, polyurethane bends, polyolefin stays clean and fluoropolymer takes heat and chemicals — and every one of them loses pressure rating as it warms. How the four families compare on SMC’s own data, how far ratings fall with temperature, minimum bend radius, why inch and metric tube are not interchangeable, and when to specify flame-resistant, antistatic or clean-room tubing.
12 min read
Pneumatics & compressed air
Push-to-connect fittings and exhaust silencers: how they grip, seal, release and slow a cylinder
A push-in fitting grips the tube with a toothed collet and seals on its outside diameter with an O-ring — so the tube cut, the tube size and the thread end decide whether it holds. How push-in fittings work, fitting and releasing tube, pressure and temperature limits by maker, NPT vs BSPT vs BSPP, and how sintered bronze, plastic and speed-control mufflers affect exhaust back-pressure and cylinder speed.
12 min read