Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10)

Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10): 62 part numbers.
Product description
Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10): 62 part numbers.
Specification
- Type: Control Valve
- Pressure stated by the maker: 4,500 psi (310 bar)
- Seal Material: Buna N
- Part numbers: 62
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function, mounting pattern (for example D03/CETOP 3 or D05/CETOP 5), port size, flow and pressure rating, and for solenoid valves the coil voltage, against the circuit before ordering.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Division | Hydraulic Valve |
| Group | Hydraulic |
| Seal Material | Buna N |
Shipping & lead time
Sizes & part numbers
62 sizes- Parker Hannifin part no.PRDM3BB01SNS
- Description
- Control Valve — Pressure 15 psi to 200 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3PP01SNS
- Description
- Control Valve — Pressure 15 psi to 200 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3AA01SNS
- Description
- Control Valve — Pressure 15 psi to 200 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3PP05SVG
- Description
- Control Valve — Pressure 29 psi to 725 psi, Port Type BSPP, Adjustment Type Screw Terminals, Port Size 1/4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 1/4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3PP05KNS
- Description
- Control Valve — Pressure 29 psi to 725 psi, Port Type SAE, Adjustment Type Knob, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Knob
- Parker Hannifin part no.PRDM3BB05SNS
- Description
- Control Valve — Pressure 29 psi to 725 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3PP05SNS
- Description
- Control Valve — Pressure 29 psi to 725 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
- Parker Hannifin part no.PRDM3AA05SNS
- Description
- Control Valve — Pressure 29 psi to 725 psi, Port Type SAE, Adjustment Type Screw Terminals, Port Size 4"
- Max pressure (psi)
- 4,500
- Rated flow (GPM)
- 21
- Mount
- NFPA D05 (CETOP 5, NG 10)
- Ports
- 4"
- Action
- Screw Terminals
Show all 62 sizesShow fewer sizes
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Rated flow — Rated flow in US gallons per minute, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Mount — Mounting flange or pattern, as published. Ports — Port type and size, as published. Action — Single- or double-acting, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) and what is it used for?▾
What part numbers does the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) cover, for example PRDM3BB01SNS?▾
What items are listed in the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) range?▾
What sizes, ports and flow ratings does the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) list?▾
How do I choose the right part number from the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10)?▾
What pressure is the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) rated for?▾
What is the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) made of?▾
How is the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) mounted or connected?▾
Which port connections does the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) list?▾
Which maximum pressures does the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) list?▾
How does the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) differ from the Parker PRDM Series Pressure Reducing Valves, NFPA D03?▾
Can I buy the Parker PRDM Series Pressure Reducing Valves, NFPA D05 (CETOP 5, NG 10) from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Reduzierung
- fr
- réducteur
- es
- reductor
- it
- riduzione
From the blog