Parker H-ISO HA Series Double Solenoid Valves, 4-Way 3-Position

Parker H-ISO HA Series Double Solenoid Valves, 4-Way 3-Position: 18 part numbers.
Product description
Parker H-ISO HA Series Double Solenoid Valves, 4-Way 3-Position: 18 part numbers.
Specification
- Type: Solenoid Valve
- Part numbers: 18
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Division | Pneumatic |
| Group | Automation |
| Iso Interface Type | ISO 15407-2, Plug In |
| Offset Return Type | Spring Return |
| Operator Type | Solenoid |
| Operator Type Detail | Double |
| Series Type | Ha Series |
| Trade Name | H |
Shipping & lead time
Sizes & part numbers
18 sizes- Parker Hannifin part no.HA5VXBG023A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition All Ports Blocked, Series H Series, Cv Fact
- Parker Hannifin part no.HA5VXBG0G9A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition All Ports Blocked, Series H Series, Cv Fact
- Parker Hannifin part no.HA6VXBG0G9A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition Center Exhaust, Series H Series, Cv Factor
- Parker Hannifin part no.HA6VXBH023A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply Internal, Override Type Locking, Center Condition Center Exhaust, Series H Series, Cv Factor 1.1
- Parker Hannifin part no.HA6VXLG0G9A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply External, Override Type Non Lockable, Center Condition Center Exhaust, Series H Series, Cv Factor
- Parker Hannifin part no.HA7VXBG023A
- Description
- Double Solenoid Valve, 4-Way, 3-Position Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition Pressure Center, Series H Series, Cv Factor
- Parker Hannifin part no.HA5VXBH0G9A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Locking, Center Condition All Ports Blocked, Series H Series, Cv Factor 1.1
- Parker Hannifin part no.HA7VXBH0G9A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Locking, Center Condition Pressure Center, Series H Series, Cv Factor 1
Show all 18 sizesShow fewer sizes
- Parker Hannifin part no.HA6VXLG023A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Non Lockable, Center Condition Center Exhaust, Series H Series, Cv Factor 1
- Parker Hannifin part no.HA5VXLG023A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Non Lockable, Center Condition All Ports Blocked, Series H Series, Cv Factor 1
- Parker Hannifin part no.HA6VXLH0G9A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Locking, Center Condition Center Exhaust, Series H Series, Cv Factor 1.1
- Parker Hannifin part no.HA7VXLG023A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Non Lockable, Center Condition Pressure Center, Series Isys Series, Cv Factor 1.1
- Parker Hannifin part no.HA6VXBG023A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition Center Exhaust, Series H Series, Cv Factor 1
- Parker Hannifin part no.HA7VXLG0G9A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Non Lockable, Center Condition Pressure Center, Series H Series, Cv Factor 1.1
- Parker Hannifin part no.HA7VXBH023A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Locking, Center Condition Pressure Center, Series H Series, Cv Factor 1
- Parker Hannifin part no.HA7VXBG0G9A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Non Lockable, Center Condition Pressure Center, Series H Series
- Parker Hannifin part no.HA6VXBH0G9A
- Description
- Pneumatic Valve — Pilot Supply Internal, Override Type Locking, Center Condition Center Exhaust, Series H Series, Cv Factor 1.1
- Parker Hannifin part no.HA5VXLG0G9A
- Description
- Pneumatic Valve — Pilot Supply External, Override Type Non Lockable, Center Condition All Ports Blocked, Series H Series, Cv Factor 1
Description — What this part number is, as the manufacturer lists it. Ask us for the dimension drawing if you need it stamped.
What is the Parker H-ISO HA double solenoid 4-way 3-position valve?▾
What do Parker HA5, HA6 and HA7 mean in part numbers like HA6VXBG023A?▾
Which centre condition do I need on the Parker HA 4/3 valve?▾
How much flow does the Parker HA 4/3 valve pass?▾
What pressure rating does the Parker HA 4/3 valve have?▾
What media can the Parker HA double solenoid 4/3 valve use?▾
Which standard does the Parker H-ISO HA 4/3 valve conform to?▾
What sub-base fits the Parker HA 4/3 valve?▾
How should a Parker HA 4/3 valve be set up to avoid surprises?▾
How does the Parker HA 4/3 compare with the HB 4/3 valve?▾
Where is the Parker HA 4/3 valve made and exported from?▾
Do you stock Parker H-ISO HA 4/3 solenoid valves in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Solenoid valve functions explained: 3/2, 5/2 and 5/3 valves, centre conditions and port numbers
What “5/2” and “5/3 closed centre” actually mean, how to read the ISO symbol in words, normally closed vs normally open 3/2 valves, single vs double solenoid 5/2 valves, the three 5/3 centre conditions and when each one is right, direct-acting vs pilot-operated valves and the pilot pressure they need, and the port numbers 1, 2, 3, 4, 5, 12 and 14.
13 min read
Pneumatics & compressed air
Sizing pneumatic valves: Cv, Kv, sonic conductance and matching a valve to a cylinder
What Cv, Kv and the ISO 6358 sonic conductance C and critical pressure ratio b each tell you, why Cv alone can mislead on air, how to work out the flow a cylinder needs and the valve Cv to deliver it using Parker’s published method, and how ISO 5599-1 plug-in valves differ from maker manifolds — including common vs individual exhaust.
13 min read








