Parker H-ISO HB Series Double Solenoid Valves, 3-Way 2-Position

Parker H-ISO HB Series Double Solenoid Valves, 3-Way 2-Position: 16 part numbers.
Product description
Parker H-ISO HB Series Double Solenoid Valves, 3-Way 2-Position: 16 part numbers.
Specification
- Type: Solenoid Valve
- Part numbers: 16
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Division | Pneumatic |
| Group | Automation |
| Iso Interface Type | ISO 15407-2, Plug In |
| Operator Type Detail | Double |
| Series | H Series |
| Series Type | Hb Series |
| Trade Name | H |
Shipping & lead time
Sizes & part numbers
16 sizes- Parker Hannifin part no.HBNVXBG023A
- Description
- Double Solenoid Valve, 3-Way, 2-Position Valve — Pilot Supply Internal, Override Type Non Lockable, Cv Factor 0.55, Center Condition Dual Valve, NC/NC
- Action
- Solenoid
- Parker Hannifin part no.HBPVXBG023A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Non Lockable, Cv Factor 0.55, Center Condition Dual Valve, NO/NO
- Action
- Solenoid
- Parker Hannifin part no.HBNVXBH0G9A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Locking, Cv Factor 0.55, Center Condition Dual Valve, NC/NC
- Action
- Solenoid
- Parker Hannifin part no.HBNVXBG0G9A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Non Lockable, Cv Factor 0.55, Center Condition Dual Valve, NC/NC
- Action
- Solenoid
- Parker Hannifin part no.HBPVXBG0G9A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Non Lockable, Cv Factor 0.55, Center Condition Dual Valve, NO/NO
- Action
- Solenoid
- Parker Hannifin part no.HBNVXBH023A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Locking, Cv Factor 0.55, Center Condition Dual Valve, NC/NC
- Action
- Solenoid
- Parker Hannifin part no.HBPVXBH0G9A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Locking, Cv Factor 0.55, Center Condition Dual Valve, NO/NO
- Action
- Solenoid
- Parker Hannifin part no.HBPVXBH023A
- Description
- Pneumatic Valve — No. Of Ways 3, Pilot Supply Internal, Override Type Locking, Cv Factor 0.55, Center Condition Dual Valve, NO/NO
- Action
- Solenoid
Show all 16 sizesShow fewer sizes
- Parker Hannifin part no.HB2VXBG023A
- Description
- Double Solenoid Valve, 4-Way, 2-Position Valve — Pilot Supply Internal, Override Type Non Lockable
- Action
- Solenoid
- Parker Hannifin part no.HB2VXBH023A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply Internal, Override Type Locking, Cv Factor 0.45
- Action
- Solenoid
- Parker Hannifin part no.HB2VXLG0G9A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply External, Override Type Non Lockable, Cv Factor 0.55
- Action
- Solenoid
- Parker Hannifin part no.HB2VXLG023A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply External, Override Type Non Lockable, Cv Factor 0.55
- Action
- Solenoid
- Parker Hannifin part no.HB2VXLH023A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply External, Override Type Locking, Cv Factor 0.45
- Action
- Solenoid
- Parker Hannifin part no.HB2VXBG0G9A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply Internal, Override Type Non Lockable, Cv Factor 0.55
- Action
- Solenoid
- Parker Hannifin part no.HB2VXBH0G9A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply Internal, Override Type Locking, Cv Factor 0.55
- Action
- Solenoid
- Parker Hannifin part no.HB2VXLH0G9A
- Description
- Pneumatic Valve — No. Of Ways 4, Pilot Supply External, Override Type Locking, Cv Factor 0.55
- Action
- Solenoid
Description — What this part number is, as the manufacturer lists it. Action — Single- or double-acting, as published. Ask us for the dimension drawing if you need it stamped.
What is the Parker H-ISO HB double solenoid valve listing?▾
How do I read Parker HBN, HBP and HB2 part numbers?▾
Which valve do I need, HBN, HBP or HB2?▾
What Cv does the Parker HB double solenoid valve have?▾
What pressure rating does the Parker HB double solenoid valve have?▾
What media can the Parker HB double solenoid valve use?▾
Which standard does the Parker HB valve follow?▾
What sub-base fits the Parker HB double solenoid valve?▾
How do I commission a Parker HB double solenoid valve?▾
How does the Parker HB 3/2 and 4/2 listing differ from the HB 4/3 valve?▾
Where is the Parker HB double solenoid valve made and exported from?▾
Do you stock Parker H-ISO HB double solenoid valves in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Solenoid valve functions explained: 3/2, 5/2 and 5/3 valves, centre conditions and port numbers
What “5/2” and “5/3 closed centre” actually mean, how to read the ISO symbol in words, normally closed vs normally open 3/2 valves, single vs double solenoid 5/2 valves, the three 5/3 centre conditions and when each one is right, direct-acting vs pilot-operated valves and the pilot pressure they need, and the port numbers 1, 2, 3, 4, 5, 12 and 14.
13 min read
Pneumatics & compressed air
Sizing pneumatic valves: Cv, Kv, sonic conductance and matching a valve to a cylinder
What Cv, Kv and the ISO 6358 sonic conductance C and critical pressure ratio b each tell you, why Cv alone can mislead on air, how to work out the flow a cylinder needs and the valve Cv to deliver it using Parker’s published method, and how ISO 5599-1 plug-in valves differ from maker manifolds — including common vs individual exhaust.
13 min read








