Membrane Water Walls

Boiler tube panels joined by flat membrane bars welded between the tubes, for furnace walls in utility and industrial boilers and HRSGs. Membrane panels form gas-tight furnace walls: the tubes carry water or steam and the membrane bars close the gaps between them, so the furnace needs no separate casing. Panels are built in shop-assembled sections with headers, bends and openings for burners, sootblowers and inspection doors where the drawing calls for them, then hydrotested before they ship. Ma
Key features
- Product type: Membrane Water Walls
- Construction: Tubes joined by flat steel membrane bars welded between them
- Standards: ASME Section I / EN 12952, ASTM A210, ASTM A192, ASTM A213 tubes; SA-36, ASTM A387 bars, ASME SA36, ASME SA387-GR12CL1, ASME SA387-GR12CL2, ASME SA387-GR22CL1, ASME SA387-GR91
- Product type
- Membrane Water Walls
- Construction
- Tubes joined by flat steel membrane bars welded between them
Product description
Boiler tube panels joined by flat membrane bars welded between the tubes, for furnace walls in utility and industrial boilers and HRSGs.
Membrane panels form gas-tight furnace walls: the tubes carry water or steam and the membrane bars close the gaps between them, so the furnace needs no separate casing. Panels are built in shop-assembled sections with headers, bends and openings for burners, sootblowers and inspection doors where the drawing calls for them, then hydrotested before they ship.
Membrane Water Walls are engineered equipment, not catalogue items. We quote against your data sheet or drawing, and the design, materials, inspection and documents follow the code and the specification you give us.
How we build and quote
Pressure parts are made to the drawing and the design code: ASME Section I for power boilers, Section VIII for vessels, or EN 12952, EN 12953 and EN 13445 under PED. Materials are supplied with mill certificates, welding is to qualified procedures and welders, and non-destructive examination, heat treatment and the hydrotest follow the code and the inspection and test plan. Third-party inspection and the documents the inspecting authority needs are arranged with the order.
Specification
- Construction: Tubes joined by flat steel membrane bars welded between them
- Tube pitch ratio: s/d usually 1.2-1.5, set by pressure and furnace heat load
- Membrane bar thickness: about 6.4 mm (1/4 in) example with 2-3 in tubes
Standards
ASME Section I / EN 12952, ASTM A210, ASTM A192, ASTM A213 tubes; SA-36, ASTM A387 bars, ASME SA36, ASME SA387-GR12CL1, ASME SA387-GR12CL2, ASME SA387-GR22CL1, ASME SA387-GR91. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Testing and documents
- Documentation, inspection and test plan to the order's code and specification
Where it is used
- Utility and industrial boilers, HRSGs
What to send for a quotation
- Drawing, or the dimensions and arrangement
- Design code (ASME Section I or VIII, EN 12952, EN 12953, EN 13445)
- Design pressure and temperature
- Material grades for tubes, plates, forgings and fittings
- NDE, heat treatment and hydrotest requirements
- Third-party inspection and the certificate the authority needs
- Quantity and delivery point
Identification
| Parameter | Value |
|---|---|
| Product type | Membrane Water Walls |
| Construction | Tubes joined by flat steel membrane bars welded between them |
Compliance
| Parameter | Value |
|---|---|
| Standards | ASME Section I / EN 12952, ASTM A210, ASTM A192, ASTM A213 tubes; SA-36, ASTM A387 bars, ASME SA36, ASME SA387-GR12CL1, ASME SA387-GR12CL2, ASME SA387-GR22CL1, ASME SA387-GR91 |
Quality
| Parameter | Value |
|---|---|
| Certification | Code documentation and inspection to the order |
Dimensions
| Parameter | Value |
|---|---|
| Size table | Engineered to order: quoted from your data sheet or drawing |
Application
| Parameter | Value |
|---|---|
| Typical services | Utility and industrial boilers, HRSGs |
Shipping & lead time
What are Membrane Water Walls used for?▾
What sizes can Membrane Water Walls be supplied in?▾
What do I need to send to get Membrane Water Walls quoted?▾
What tube pitch and membrane bar thickness do membrane water walls use?▾
How are Membrane Water Walls built, examined and documented?▾
What tubes and bars are Membrane Water Walls made from?▾
Which codes and standards apply to Membrane Water Walls?▾
What do Membrane Water Walls connect to or work with?▾
What inspection and documents come with Membrane Water Walls?▾
Where are Membrane Water Walls typically used?▾
Can Membrane Water Walls be supplied to customers outside the UAE?▾
Do you hold Membrane Water Walls in stock, or are they made to order?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations