Frac Shunt (Zipper) Manifold, 15,000 to 20,000 psi

Frac shunt (zipper) manifolds for multi-well fracturing: 4-1/16" to 7-1/16", 15,000 to 20,000 psi, frac valves with ball-screw drive, eight-way or single-channel heads, skid-mounted, modular.
Key features
- Valve type: Frac manifold, shunt (zipper)
- Construction: Frac valves, eight-way or single-channel heads, skid
- Design standard: API 6A (21st edition)
- Size range: 4-1/16" to 7-1/16" main; 3-1/16" bypass
- Pressure class: 15,000 to 20,000 psi working pressure
- Body material: API 6A material classes AA to HH (DD to HH for sour service)
- End connections: Flanged
- Operation: Manual (ball-screw) or hydraulic frac valves
- Valve type
- Frac manifold, shunt (zipper)
- Design standard
- API 6A (21st edition)
- Pressure class
- 15,000 to 20,000 psi working pressure
- End connections
- Flanged
- Operation
- Manual (ball-screw) or hydraulic frac valves
Product description
Feeds several wellheads from one frac spread so wells can be fractured one after another without rigging down. Single-channel versions give maximum rate to each well; eight-way versions split the flow through frac heads, with each channel opened and closed by its own frac valve.
Pressure-control and well-service equipment is the hardware between the well and everything downstream: it holds and directs well pressure while drilling, testing, stimulating and producing. Each piece is built to API 6A, 16A or 16C for its working pressure, temperature class and material class, with sour-service materials to NACE MR0175 / ISO 15156 where the well needs them.
Construction
- Large bore for high-rate fracturing
- Integral skid: rigid, compact, easy to connect
- Modular layout, adjustable on site
- Full-bore, bidirectional frac valves with spring-energised seals and ball-screw drive
Sizes and ratings
Published range: 4-1/16" to 7-1/16" main; 3-1/16" bypass, 15,000 to 20,000 psi working pressure, in api 6a material classes aa to hh (dd to hh for sour service). End connections: Flanged. Operation: manual (ball-screw) or hydraulic frac valves.
Each unit is configured to the job; the general arrangement drawing and data book index come with the quotation.
Testing and documents
Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls, with the material certificates and the pressure-test record supplied with the equipment. Third-party inspection and extra tests are added when the order specifies them.
Supply
Frac shunt manifolds are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator; standard carbon-steel sizes move fastest. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other frac manifolds in the range, for comparison when the duty is not settled yet: High and Low Pressure Frac Manifold (Missile), 15,000 to 20,000 psi, Universal (E-Type) Frac Manifold, 15,000 to 20,000 psi.
Materials
| Parameter | Value |
|---|---|
| Body material | API 6A material classes AA to HH (DD to HH for sour service) |
| Seat and trim | PSL 1 to 3; PR1 |
Range
| Parameter | Value |
|---|---|
| Temperature range | -60 °C to 121 °C (K to V) |
| Size range | 4-1/16" to 7-1/16" main; 3-1/16" bypass |
| Pressure class | 15,000 to 20,000 psi working pressure |
Identification
| Parameter | Value |
|---|---|
| Valve type | Frac manifold, shunt (zipper) |
| Construction | Frac valves, eight-way or single-channel heads, skid |
Standards
| Parameter | Value |
|---|---|
| Design standard | API 6A (21st edition) |
| Pressure testing | Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls |
Construction
| Parameter | Value |
|---|---|
| End connections | Flanged |
| Operation | Manual (ball-screw) or hydraulic frac valves |
Application
| Parameter | Value |
|---|---|
| Typical service | Multi-well zipper fracturing |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with the documentation and test record |
Shipping & lead time
What is a frac shunt (zipper) manifold used for?▾
What sizes and pressures does the frac shunt (zipper) manifold cover?▾
What are the valves on the frac shunt (zipper) manifold?▾
Can the frac shunt (zipper) manifold be supplied for sour service?▾
What standard is the frac shunt (zipper) manifold built to?▾
What does the frac shunt (zipper) manifold connect to?▾
Should I choose a single-channel or eight-way zipper manifold?▾
Where is the frac shunt (zipper) manifold used?▾
How many wells can one frac shunt (zipper) manifold serve?▾
What should I send for a zipper manifold quotation?▾
Is the frac shunt (zipper) manifold skid mounted?▾
Does Indus stock the frac shunt (zipper) manifold?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog