High and Low Pressure Frac Manifold (Missile), 15,000 to 20,000 psi

Skid-mounted high and low pressure frac manifolds (missiles): 4-1/16" to 7-1/16", 15,000 to 20,000 psi, plug and check valves on every pump port, relief and transmitter ports.
Key features
- Valve type: Frac manifold, high and low pressure (missile)
- Construction: HP and LP manifolds, plug and check valves on skid
- Design standard: API 6A (21st edition)
- Size range: 4-1/16" to 7-1/16" main; 3-1/16" bypass
- Pressure class: 15,000 to 20,000 psi working pressure
- Body material: API 6A material classes AA to FF
- End connections: Hammer union and flanged
- Operation: Manual plug valves
- Valve type
- Frac manifold, high and low pressure (missile)
- Design standard
- API 6A (21st edition)
- Pressure class
- 15,000 to 20,000 psi working pressure
- End connections
- Hammer union and flanged
- Operation
- Manual plug valves
Product description
The hub of the frac spread. The low-pressure side distributes blended fluid from the blender to each pump; the high-pressure side gathers pump discharge and sends it to the well. Every pump port carries a plug valve and check valve so a pump can be isolated without stopping the job.
Pressure-control and well-service equipment is the hardware between the well and everything downstream: it holds and directs well pressure while drilling, testing, stimulating and producing. Each piece is built to API 6A, 16A or 16C for its working pressure, temperature class and material class, with sour-service materials to NACE MR0175 / ISO 15156 where the well needs them.
Construction
- High-pressure and low-pressure manifolds on one skid
- Plug and flapper check valves on every pump port, height-adjustable
- Adapters to match pump discharge connections
- Relief valve and pressure-transmitter ports; fixed lifting supports
Sizes and ratings
Published range: 4-1/16" to 7-1/16" main; 3-1/16" bypass, 15,000 to 20,000 psi working pressure, in api 6a material classes aa to ff. End connections: Hammer union and flanged. Operation: manual plug valves.
Each unit is configured to the job; the general arrangement drawing and data book index come with the quotation.
Testing and documents
Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls, with the material certificates and the pressure-test record supplied with the equipment. Third-party inspection and extra tests are added when the order specifies them.
Supply
High and low pressure frac manifolds are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator; standard carbon-steel sizes move fastest. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other frac manifolds in the range, for comparison when the duty is not settled yet: Universal (E-Type) Frac Manifold, 15,000 to 20,000 psi, Frac Shunt (Zipper) Manifold, 15,000 to 20,000 psi.
Materials
| Parameter | Value |
|---|---|
| Body material | API 6A material classes AA to FF |
| Seat and trim | PSL 1 to 3; PR1 |
Range
| Parameter | Value |
|---|---|
| Temperature range | -60 °C to 121 °C (K to V) |
| Size range | 4-1/16" to 7-1/16" main; 3-1/16" bypass |
| Pressure class | 15,000 to 20,000 psi working pressure |
Identification
| Parameter | Value |
|---|---|
| Valve type | Frac manifold, high and low pressure (missile) |
| Construction | HP and LP manifolds, plug and check valves on skid |
Standards
| Parameter | Value |
|---|---|
| Design standard | API 6A (21st edition) |
| Pressure testing | Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls |
Construction
| Parameter | Value |
|---|---|
| End connections | Hammer union and flanged |
| Operation | Manual plug valves |
Application
| Parameter | Value |
|---|---|
| Typical service | Frac pump spreads: frac fluid, proppant, acid, water |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with the documentation and test record |
Shipping & lead time
What is a high and low pressure frac manifold (missile) used for?▾
What sizes and pressures does the high and low pressure frac manifold (missile) cover?▾
What temperature and material classes does the high and low pressure frac manifold (missile) offer?▾
What fluids can the high and low pressure frac manifold (missile) handle?▾
Is the high and low pressure frac manifold (missile) made to API 6A?▾
What valves are on every pump port of the high and low pressure frac manifold (missile)?▾
How does the high and low pressure frac manifold (missile) differ from the 16-pumper missile?▾
Where is the high and low pressure frac manifold (missile) used?▾
What should I send for a frac manifold quotation?▾
How many pumps can the high and low pressure frac manifold (missile) serve?▾
Can the high and low pressure frac manifold (missile) be supplied to an operator specification?▾
Does Indus stock the high and low pressure frac manifold (missile)?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog