Skip to content
IH-TF-UK-CUA

Copper-Alloy U-Bend Tubes — ASTM B395

Copper-Alloy U-Bend TubesEx-stock · delivery in 3 days
Copper-alloy U-bend tubes nested by radius, with spacers along the legs
VIEW 01·Copper-alloy U-bend tubes nested by radius, with spacers along the legs

U-tubes in copper, admiralty and aluminium brass and copper-nickel to ASTM B395, for coolers and condensers with removable bundles. Made to ASTM B395/B395M, ASTM B111, ASTM B135. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.

Key features

  • Product type: Copper-Alloy U-Bend Tubes
  • Construction: Bent from straight seamless or welded tube
  • Standards: ASTM B395/B395M, ASTM B111, ASTM B135, ASTM B68, BS 2871, BS EN12451, EN 12735-2, JIS H3300
  • Base tube material: C12200 etc.; C44300–C44500; C68700; C70600/C70620; C71500/C71520; C72200
  • Wall thickness: Per the governing specification on the order (ASTM A688 / TEMA, or A556 / B395) — no single percentage
Product type
Copper-Alloy U-Bend Tubes
Construction
Bent from straight seamless or welded tube
Base tube material
C12200 etc.; C44300–C44500; C68700; C70600/C70620; C71500/C71520; C72200
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

U-tubes in copper, admiralty and aluminium brass and copper-nickel to ASTM B395, for coolers and condensers with removable bundles. Bends are relief-annealed where the alloy needs it, and a dual-gauge tube with a heavier bend section is available.

Specification

  • Minimum bend radius: 1.5×OD centreline radius available; dimensional tolerances guaranteed from 2×OD
  • Wall thinning at the bend: Per the governing specification on the order (ASTM A688 / TEMA, or A556 / B395) — no single percentage
  • Bend heat treatment: To order: stress-relief or solution anneal of the bend plus ~150 mm of leg (A688), or ≥300 mm where the project specification requires
  • Leg length: Up to ~12 m typical; straight tube up to 30 m on request
  • Size scope: OD ≤2 in (50 mm)
  • Leg spacing tolerance: (2R − OD) ±1.6 mm (1/16 in)
  • Leg length tolerance (all plus): ≤6 m +3.2; 6–9 m +4.0; 9–18 m +6.4; >18 m +9.5 mm; leg difference ≤3.2 mm
  • Dual-gauge option: bend section one BWG heavier, constant ID; heavy section ≥100 mm long

Standards

ASTM B395/B395M, ASTM B111, ASTM B135, ASTM B68, BS 2871, BS EN12451, EN 12735-2, JIS H3300. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.

Materials

  • Tube: C12200 etc.; C44300–C44500; C68700; C70600/C70620; C71500/C71520; C72200

Testing and documents

  • Eddy current before bending
  • Hydrostatic at 48 MPa fibre stress (≤6.9 MPa) or pneumatic 400 kPa for 5 s, on each U-tube
  • Mercurous nitrate / ammonia vapour on bend and leg for brasses
  • Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan

Where it is used

  • U-tube feedwater heaters, coolers and chillers

Standard geometry

Alloy / temperWall (mm)Wall (in)Min centreline bend radius
C71500 / C71520 HR501.240.0492.2 × OD
C71500 / C71520 HR501.470.0582.0 × OD

These are the limits of the standard, not part numbers. Each item is made to your drawing.

Ordering

Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the bend schedule: centreline radius and leg length for each row, and any heat treatment of the bends. We quote with the mill certificates and the inspection you need.

Identification

ParameterValue
Product typeCopper-Alloy U-Bend Tubes
ConstructionBent from straight seamless or welded tube

Compliance

ParameterValue
StandardsASTM B395/B395M, ASTM B111, ASTM B135, ASTM B68, BS 2871, BS EN12451, EN 12735-2, JIS H3300

Construction

ParameterValue
Base tube materialC12200 etc.; C44300–C44500; C68700; C70600/C70620; C71500/C71520; C72200

Dimensions

ParameterValue
Wall thicknessPer the governing specification on the order (ASTM A688 / TEMA, or A556 / B395) — no single percentage
LengthRandom or fixed lengths; cut to length on request
Bend radius1.5×OD centreline radius available; dimensional tolerances guaranteed from 2×OD
Size tableMade to your drawing; standard geometry in the description

Quality

ParameterValue
TestingEddy current before bending; Hydrostatic at 48 MPa fibre stress (≤6.9 MPa) or pneumatic 400 kPa for 5 s, on each U-tube; Mercurous nitrate / ammonia vapour on bend and leg for brasses
CertificationMill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement

Application

ParameterValue
Typical servicesU-tube feedwater heaters, coolers and chillers

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

From the blog